Search
753 articles for “Current Control”
-
Comparison of Aircraft System using Fuzzy Logic Control and Traditional Control Scheme
Abstract: Sinusoidal current control (SCC) strategy is used for hauling out reference currents. This technique has been reviewed for More Electric Aircraft (MEA) system. Further, SCC strategy’s compensation capability has been compared with the system optimized using FLC. The basis for comparison is Harmonic distortion and compensation time. Result based on MATLAB Simulink will prove the effectivity of the control strategy for SAF in the MEA system.Keywords: More electric aircraft system …
Published in Journal of Aerospace Engineering & Technology · Vol. 8, Issue 3, 2018 · pp. 34–42 Read article
-
Evaluation of OTA Amplifier Using EEG Signals
Abstract: AbstractOver the last few years, there has been a tremendous exploration in VLSI industries in response to scaling trends towards deep submicron technology. Demand for low power and efficient amplification are rising in day-to-day life. In the process of scaling the CMOS nanometer demand low supply, which is helped to design digital circuit realization at very low power consumption. But it is not valid for analog circuit realization. The related …
Published in Trends in Opto-electro & Optical Communication · Vol. 10, Issue 2, 2020 · pp. 5–14 Read article
-
Power Factor Correction Using Parallel Boost Converter
Abstract: Power factor, the ratio between the active or average power and the apparent power forms a very essential parameter of the power system. It is indicative of how effectively the active power of the system has been utilized. With rapid development in power semiconductor devices, the usage of power electronic systems has expanded to a new and wide application range that include residential, commercial, aerospace and many others. Power electronic …
Published in Trends in Electrical Engineering · Vol. 5, Issue 3, 2015 · pp. 71–88 Read article
-
Closed Loop Control of Interleaved Buck Converter with Extremely Low Output Current Ripple
Abstract: AbstractIn this paper, the analysis and modeling of interleaved buck converter with PI controller is discussed. Converters are controlled by two active switches, which have the same switching frequency but 180° out of phase. The loss associated with the power device is half of the input voltage and the duty cycle is below 50%. By paralleling the converters, the input current can be shared among the inductors so that high …
Published in Journal of Semiconductor Devices and Circuits · Vol. 5, Issue 2, 2018 · pp. 9–18 Read article
-
A Comparative Study of ANN and Traditional Control Techniques based Active Shunt Power Filter for 400 Hz Aircraft Electric Power System
Abstract: Sinusoidal current control strategy for extracting reference current for shunt active power filters have been modified using artificial neural network (ANN) and its performances have been compared too. The acute analysis of comparison of the compensation capability is based upon THD, speedwell and recommendations will be given for the choice of technique to be used. The simulated results using MATLAB model are shown in this paper, and they will undoubtedly …
Published in Trends in Electrical Engineering · Vol. 6, Issue 1, 2016 · pp. 42–49 Read article
-
Performance Evaluation of Active Power Filter for Aircraft System
Abstract: Sinusoidal current control approach for extracting reference currents for shunt lively energy filters were modified using genetic algorithm and its performances had been compared. The acute evaluation of comparison of the repayment functionality based on THD and speedwell be finished, and pointers may be given for the selection of method for use. The simulated effects the usage of MATLAB version are shown, and they will undoubtedly prove the significance of …
Published in Journal of Power Electronics and Power Systems · Vol. 7, Issue 1, 2017 · pp. 1–8 Read article
-
Shunt Active Power Filter Using Three Level Inverter without PI Controller
Abstract: This paper presents simulation and analysis of shunt active power filter using three level inverter. Different types of filters can be used for elimination of harmonics in the power system with nonlinear load. Three level VSI (Voltage Source Inverter) can be used for high voltage application. Three level NPC (Neutral Point Clamped) VSI is used for active power filter. In this paper, FFT (Fast Fourier Transform) algorithm for reference current …
Published in Journal of Power Electronics and Power Systems · Vol. 5, Issue 3, 2015 · pp. 76–86 Read article
-
HCC Based Hybrid Shunt Active Filter to Reduce the Harmonics Due to Switching Surges
Abstract: This paper deals with the hysteresis current control based hybrid shunt active filter to reduce the harmonics produced by frequent switching of industrial loads in distribution system. The main harmonic sources of distribution lines are the non linear loads and frequent switching of industrial loads. The harmonics due to non linear loads can be controlled by passive filters. The switching surges are dynamic and its magnitude dies out quickly. Hence …
Published in Trends in Electrical Engineering · Vol. 3, Issue 2, 2013 · pp. 15–19 Read article
-
RTDS Hardware Implementation and Simulation of 3-ph 4-wire SHAF for Mitigation of Current Harmonics using p-q Control strategy With Fuzzy Controller
Abstract: The main objective of this paper is to develop Fuzzy controller to analyse the performance of instantaneous realactive and reactive power (p–q) control strategy for extracting reference currents of shunt active filters underbalanced, un-balanced and balanced non-sinusoidal conditions. When the supply voltages are balanced andsinusoidal, the all control strategies are converge to the same compensation characteristics; However, thesupply voltages are distorted and/or un-balanced sinusoidal, these control strategies result in different …
Published in Journal of Power Electronics and Power Systems · Vol. 1, Issue 1-2-3, 2011 · pp. 59–71 Read article
-
Survey of Advanced Control Techniques for Active Power Filters in Grid Integration
Abstract: Active power filters (APFs) can increase power quality, dependability, and stability on power utilities by compensating for harmonic and reactive current components in power supplies. The performance and stability of active power filters are greatly enhanced by the control strategies used with them. When these two crucial elements start to compete, it is impossible to achieve both unity power factor (UPF) and flawless correction of current harmonics. A systematic review …
Published in Current Trends in Signal Processing · Vol. 13, Issue 3, 2023 · pp. 24–34 Read article
-
Comparative Critical Analysis of Control Techniques Optimized using ATS Algorithm and Conventional Control Techniques Applied in Shunt Active Power Filter for Total Harmonic Reduction for Power Electronic Converters in High Frequency (400 Hz) Aircraft Sys
Abstract: Three different conventional control strategies used for extracting reference currents for shunt active power filter and optimization of these strategies using Adaptive Tabu Search have been compared and their performances have been evaluated under different balanced and unbalanced loads connected together. The compensation ability of different control strategies will be compared, and suggestion will be given for optimum. Simulation results using MATLAB have been included. Keywords: Active powers filter (APF), …
Published in Journal of Aerospace Engineering & Technology · Vol. 5, Issue 3, 2015 · pp. 44–52 Read article
-
Harmonic Compensation in Grid Interconnected DG Units by Closed Loop Control
Abstract: This paper deals with improvement of power quality problem namely harmonic problem using distributed generation as their source of electricity. The harmonics occur in such a system because of the nature of loads connected. There are many power quality problems; out of which harmonics normally caused by nonlinear loads like variable frequency drives, fluorescent lightning, office computers etc. have adverse effects on the power quality. Also, harmonic detection and prediction …
Published in Journal of Power Electronics and Power Systems · Vol. 7, Issue 1, 2017 · pp. 9–17 Read article
-
Controlled Release Drug Delivery Using 3D Printing Techniques: A Current Scenario In Personalized Medicine
Abstract: Three-dimensional (3D) printing is particularly influencing the pharmaceutical manufacturing sector in the creation of controlled release drug delivery systems. This technology enables the precise fabrication of personalized medicines with tailored drug release profiles, dosages, and geometries, marking a significant advancement over traditional mass production methods. An array of 3D printing techniques, including extrusion-based, powder-based, and others, can be used to build complex dosage forms that regulate drug release through processes …
Published in Trends in Drug Delivery · Vol. 12, Issue 3, 2025 · pp. 28–43 Read article
-
Topology, Operation and Control of Modular Multilevel Converter for Grid Application: A Review
Abstract: Modular multilevel converter (MMC) is a widely accepted technology for high voltage direct-current (HVDC) application. Due to its modularity, scalability, power quality, and no need of bulky filter on ac side, they are widely used as voltage source converters in HVDC applications. This paper presents a comprehensive study on MMC technology for grid applications along with different modulation techniques and voltage balancing strategies which are essential for the converter to …
Published in Trends in Electrical Engineering · Vol. 7, Issue 1, 2017 · pp. 25–47 Read article
-
Transient Analysis of a Grid-Connected Hybrid Wind-PV System
Abstract: A new reliable hybrid distributed generation (DG) system based on photovoltaic (PV) and wind driven permanent magnet synchronous generator (PMSG) as sources, with only a boost converter followed by an inverter stage is being developed. The proposed hybrid generator has a PV array being directly connected to the dc link instead of a dc-dc converter. The dc-dc converter varies the dc-link voltage and is placed in between the rectifier fed …
Published in Journal of Power Electronics and Power Systems · Vol. 6, Issue 2, 2016 · pp. 55–63 Read article
-
Control of a Three Phase Grid-Connected Photovoltaic System with Maximum Power Point Tracking
Abstract: The power output of a photovoltaic system is greatly dependent on environmental conditions such as solar irradiation and ambient temperature. Due to the nonlinear nature of these conditions, the power output of the PV system is nonlinear. As a result, interfacing its output to the electrical grid is not possible. In order to achieve a grid connected photovoltaic (PV) system, controlled maximum power point tracking techniques are needed to obtain …
Published in Journal of Power Electronics and Power Systems · Vol. 5, Issue 3, 2015 · pp. 52–64 Read article
-
A Comprehensive Study of Risk-Adaptive Access Control in Advanced Database Management Systems
Abstract: The current control methods for the accession of a crucial resource often struggle to provide adequate security in dynamic and complex advanced database management systems (DBMS). These static models lack the flexibility to adapt to evolving threats and contextual changes, leaving potential vulnerabilities. Risk-adaptive access control (RadAC) emerges as a sophisticated solution, integrating real-time risk assessment into authorization decisions to dynamically adjust access permissions. This review article provides a comprehensive …
Published in Journal of Advanced Database Management & Systems · Vol. 13, Issue 1, 2026 · pp. 19–28 Read article
-
Design and Simulation of Maximum Power Point Tracking Solar Battery Charge Controller
Abstract: As solar energy is a renewable energy that has the capacity to lessen energy crisis in the world, so there is a strong need to harvest and utilize this energy. This paper describes the simulation of a solar energy based MPPT battery charger controller and a protection system will also be integrated with the design. The proposed design uses PID controller based voltage and current controller for battery charging circuit. …
Published in Trends in Electrical Engineering · Vol. 7, Issue 2, 2017 · pp. 11–20 Read article
-
Harmonic Mitigation in Shunt Active Power Filter Regulation Approaches with Synchronous Reference Frame: An Extensive Analysis
Abstract: The Shunt Active Power Filter (SAPF) is discussed in this work as a means of removing line-side current harmonics. The Voltage Source Inverter (VSI) topology serves as the foundation for the Active Power Filter. It resolves the power system's harmonic current issue. Additionally, it balances the load on three phases and compensates for reactive power (if load is unbalanced). After measuring load current, it switches to the dq0 coordinate system. …
Published in Journal of Microcontroller Engineering and Applications · Vol. 10, Issue 3, 2023 · pp. 6–15 Read article
-
Transient Response Analysis of DFIG Using Direct Rotor Control Technique
Abstract: This study has a depth of a logical outcome of indirect and direct rotor current-mode control technique (CMC). It deals with the rotor-side converter of induction generators in different grid fault conditions by doing simulation in MATLAB software; here improvement of the transient response is in focus, it concerns the dynamic performance achieved with the conventional method or indirect CMC method. In this study, two methods were being compared and …
Published in Trends in Electrical Engineering · Vol. 8, Issue 2, 2018 · pp. 39–45 Read article