Trends in Electrical Engineering

Transient Response Analysis of DFIG Using Direct Rotor Control Technique

  1. Amit R. Pathak ✉
  2. Anoop H. Budhrani
  3. Hardik M. Pandya
  4. Raghuvaran S. Naidu

Abstract

This study has a depth of a logical outcome of indirect and direct rotor current-mode control technique (CMC). It deals with the rotor-side converter of induction generators in different grid fault conditions by doing simulation in MATLAB software; here improvement of the transient response is in focus, it concerns the dynamic performance achieved with the conventional method or indirect CMC method. In this study, two methods were being compared and by its analytical review, result being presented in terms of graphical way. In this study, simulation being done by considering 9 MW grid-connected wind turbine DFIG type generating system.Keywords: Current-mode control (CMC), doubly fed induction generator (DFIG), grid fault, wind energy, wind turbine, wind power generationCite this ArticleAmit R. Pathak, Anoop H. Budhrani, Hardik M. Pandya et al. Transient Response Analysis of DFIG Using Direct Rotor Control Technique. Trends in Electrical Engineering. 2018; 8(2): 39–45p.

References (10)

  1. Castilla M, Miret J, Matas J, Borrell A, Vicuna LGD. Direct Rotor Current -Mode Control Improves the Transient Response of Doubly Fed Induction Generator Based Wind Turbines . IEEE Transactions On Energy Conversion . 2010; 25 (3): 722 – 731p.
  2. Pena R, Clare JC, Asher GM. Doubly fed induction generator using back -to-back PWM converters and its application to variable-speed wind -energy generation . IEE Proc. Electr. Power Appl. 1996; 143 (3): 231–241p.
  3. Chen Z, Guerrero JM, Blaabjerg F. A review of the state of the art of pow er electronics for wind turbines . IEEE Trans. Power Electron. 2009; 24 (8): 1859– 1875p.
  4. Kasem H, El-Saadany EF, El-Tamaly HH, Wahab MA. An improved fault ride - through strategy for doubly fed induction generator based wind turbines . IET Renewable Power Generation 2008; 2 (4): 201–214p.
  5. Xiang D, Ran L, Tavner PJ, Yang S. Control of a doubly fed induction generator in a wind turbine during grid fault ride -through. IEEE Trans. Energy Convers. 2006; 21 (3): 652–662p.
  6. Pathak A, Nehete A, Shinde R. Comparison of Indirect and Direct Rotor Current-Mode Control of DFIG Based Wind Turbines. IJNGCA. 2013; 1 (9): 3p.
  7. Muljadi E, Butterfield CP, Parsons B, Ellis A. Effect of variable speed wind turbine generator on stability of a weak grid. IEEE Trans. Energy Convers. 2007; 22 (1): 29– 36p.
  8. Muyeen SM, Takahaski R, Ali MH, Murata T, Tamura J. Transient stability augmentation of power system including wind farms by using ECS . IEEE Trans. Power Syst. 2008; 23 (3): 1179–1187p.
  9. Munteanu I, Bacha S, Bratcu AI, Guiraud J, Roye D. Energy reliability optimization of wind energy conversion systems by sliding mode control. IEEE Trans. Energy Convers. 2008; 23 (3): 975–985p.
  10. Pena R, Clare JC, Asher GM. Doubly fed induction generator using back -to-back PWM converters and its application to variable-speed wind -energy generation . IEEE Proc. Electr. Power Appl. 1996; 143 (3): 231–241p. Cite this Article Amit R. Pathak, Anoop H. Budhrani, Hardik M. Pandya et al. Transient Response Analysis of DFIG Using Direct Rotor Control Technique . Trends in Electrical Engineering . 2018; 8(2): 39–45p.