Research & Reviews : Journal of Physics
Generation of Wind Power using Doubly Fed Induction Generator
Abstract
Due to independent controlling mechanism for the active and reactive power, doubly fed induction generator (DFIG) is still culled by the wind turbine companies. The control strategies are continuously advancing to manage the grid codes (i.e. reactive power compensation, low voltage ride-through operation). This paper focuses on the control strategies using combined reactive power compensation for power converters to maintain the optimized lifetime distribution under normal grid conditions. An advanced demagnetizing control is also discussed which maintains the minimum thermal stress of the rotor-side converter in case of the short-term grid fault. A modularized control strategy of the DFIG system under unbalanced and distorted grid voltage is also presented, which discusses the control targets of the smooth active and reactive power and balanced sinusoidal current of the rotor-side as well as the grid-side converter. In this paper, the limitations of control strategy implementation for wind turbines are also discussed.Keywords: Doubly-fed induction motor, reactive power, low voltage ride-through unbalanced distortedCite this ArticleGargi Mishra, Ramit Mohan, Kartik Kapoor et al. Generation of Wind Power using Doubly Fed Induction Generator. Research & Reviews: Journal of Physics. 2018; 7(3): 73–78p.References (39)
- Chinchilla M, Arnaltes S, Burgos J C. Control of permanent -magnet generators applied to variable -speed wind -energy systems connected to the grid. IEEE Transactions on energy conversion . 2006; 21(1):130–135p.
- Liwschitz MM, Kilgore LA. A Study of the Modified Kramer or Asynchrono us- Synchronous Cascade Variable -Speed Drive. Trans Am Inst Electr Eng . 1942;61(5):255–260p.
- Bocquel A, Janning J. 4*300 MW Variable Speed Drive for Pump -Storage Plant Application. EPE 2003.2003;1–10p.
- Muller S, Deicke M, De Doncker RW. Doubly Fed Induction Generator Systems for Wind Turbines. IEEE IndAppl Mag.2002;8(3):26–33p.
- Shively EK, Whitlow GS. Automatic Control for Variable Ratio Frequency Converters. Trans Am Inst Electr Eng . 1932;51(1):121–127p.
- Larsson A. Flicker Emission o f Wind Turbines during Continuous Operation. IEEE Trans Energy Convers . 2002;17(1):114–118p.
- Seman S, Niiranen J, Virtanen R, et al. Low Voltage Ride -through Analysis of 2 MW DFIG Wind Turbine -Grid Code Compliance Validations. In Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century, 2008 IEEE. Jul 2008; 1–6p.
- Li S, Haskew TA, Williams KA, et al. Control of DFIG Wind Turbine with Direct-Current Vector Control Configuration. IEEE Trans Sustain Energ. 2012;3(1):1–11p.
- Soliman M, Malik OP, Westwick DT. Multiple Model Predictive Control for Wind Turbines with Doubly Fed Induction Generators. IEEE Trans Sustain Energ. 2011;2(3):215–225p.
- Choudhury S, Mohanty KB, Chitti Babu B. Performance Analysis of Doubly Fed Induction Generator for Wind Energy Conversion System. The 5th PSU -UNS International Conference on Engineering and Technology (ICET -2011), Phuket, Prince of Songkla Un iversity, Faculty of Engineering Hat Yai, Songkhla, Thailand 90112. May 2–3, 2011; 532–536p.
- Datta R, Ranganathan VT. Variable -Speed Wind Power Generation Using Doubly Fed Wound Rotor Induction Machine: A Comparison with Alternative Schemes. IEEE Trans Ene rgy Convers . 2002; 17(3):414–421p.
- Qiao W, Harley RG. Power Quality and Dynamic Performance Improvement of Wind Farms Using a STATCOM. In Power Electronics Specialists Conference, 2007 (PESC 2007), IEEE. Jun 2007; 1832 – 1838p.
- Allan E, Jenkins N, Castro F, et al. Large Wind Turbines and Weak Rural Electricity Systems. In Proceedings of the BWEA Conference, Stirling. Jun 1994.
- Craig LM, Davidson M, Jenkins N, et al. Integration of Wind Turbines on Weak Rural Networks. International Conference on Opportunities and Advances in International Power Generation . 1996; 164–167p.
- Uctug MY, Eskandarzadeh I, Ince H. Modelling and Output Power Optimisation of a Wind Turbine Driven Double Output Induction Generator. IEE Proc Electric Power Applications. 1994;141(2):33–38p.
- Wu B, Lang Y, Zargari N, et al. Power Conversion and Control of Wind Energy Systems. John Wiley & Sons; 2011.
- Akhmatov V. Analysis of Dynamic Behavior of Electric Power Systems with Large Amount of Wind Power. PhD Thesis. Electrical Power Engineering , Technical University of Denmark; Apr 2003.
- Statistics E, Central Statistics Office, Ministry of Statistics and Programme Generation of Wind Power using DFIG Mishra et al. RRJoPHY (2018) 73-78 © STM Journals 2018. All Rights Reserved Page 78 Implementation Government of India, New Delhi. 2018.
- Sethi JK, Deb D, Malakar M. Modeling of a Wind Turbine Farm in Presence of Wake Interactions. In Energy, Automation, and Signal (ICEAS), 2011 International Conference on, IEEE. Dec 2011; 1–6p.
- Xu L, Zhi D, Williams BW. Predictive Current Control of Doubly Fed Induction Generators. IEEE Trans Ind Electron . 2009; 56(10):4143–4153p.
- Wei X, Chen DY, Zhao CY. A Torque Ripple Minimization Scheme in Direct Torque Control of Induction Motors. Techniques of Automation and Applications. 2005; 8:024p.
- Manwell JF, McGowan JG, Rogers AL. Wind Energy Explained: Theory, Design and Application . John Wiley & Sons; 2010.
- Salman SK, Teo AL. Windmill Modeling Consideration and Factors Influencing the Stability of a Grid -Connected Wind Power-Based Embedded Generator. IEEE Trans Power Syst. 2003;18(2):793–802p.
- Sun T, Chen Z, Blaabjerg F. Flicker Study on Variable Speed Wind Turbines with Doubly Fed Induction Generators. IEEE Trans Energy Convers . 2005;20(4):896– 905p.
- Vepa R. Nonlinear, Optimal Control of a Wind Turbine Generator. IEEE Trans Energy Convers. 2011;26(2):468–478p.
- Leonhard W. Control of Electrical Drives. Springer Science & Business Media; 2001.
- Beltran B, Benbouzid MEH, Ahmed -Ali T. Second-Order Sliding Mode Control of a Doubly Fed Induction Generator Driven Wind Turbine. IEEE Trans En ergy Convers. 2012;27(2):261–269p.
- Rouco L, Zamora JL. Dynamic Patterns and Model Order Reduction in Small - Signal Models of Doubly Fed Induction Generators for Wind Power Applications. In Power Engineering Society General Meeting, 2006, IEEE. 2006; 8p.
- Pfeiffer A, Scheidl W, Eitzmann M, et al. Modern Rotary Converters for Railway Applications. In Railroad Conference, 1997, Proceedings of the 1997 IEEE/ASME Joint. Mar 1997; 29–33p.
- Lu H, Yuan Z, Wei L, et al.US Patent No. 8,570,003. Washington, DC: US Pat ent and Trademark Office; 2013.
- Tazil M, Kumar V, Bansal RC, et al. Three-Phase Doubly Fed Induction Generators: An Overview. IET Electr Power Appl. 2010;4(2):75–89p.
- Hu J, Nian H, Hu B, et al. Direct Active and Reactive Power Regulation of DFIG Using Sliding -Mode Control Approach. IEEE Trans Energy Convers . 2010;25(4):1028–1039p.
- Zhi D, Xu L. Direct Power Control of DFIG with Constant Switching Frequency and Improved Transient Performance. IEEE Trans Energy Convers . 2007;22(1):110–118p.
- Mohseni M, Islam SM, Masoum MA. Enhanced Hysteresis -Based Current Regulators in Vector Control of DFIG Wind Turbines. IEEE Trans Power Electron. 2011;26(1):223–234p.
- Muller S, Deicke M, De Doncker RW. Doubly Fed Induction Generator Systems for Wind Turbine s. IEEE Ind Appl Mag . 2002;8(3):26–33p.
- Nunes MV, Lopes JP, Zurn HH, et al. Influence of the Variable -Speed Wind Generators in Transient Stability Margin of the Conventional Generators Integrated in Electrical Grids. IEEE Trans Energy Convers. 2004;19(4):692–701p.
- Morren J, De Haan SW. Ride through of Wind Turbines with Doubly-Fed Induction Generator during a Voltage Dip. IEEE Trans Energy Convers. 2005; 20(2):435– 441p.
- Xu L, Zhi D, Williams BW. Predictive Current Control of Doubly Fed Induction Generators. IEEE Trans Ind Electron . 2009;56(10):4143–4153p.
- Pena R, Clare JC, Asher GM. Doubly Fed Induction Generator Using Back -to-Back PWM Converters and Its Application to Variable-Speed Wind -Energy Generation. IEE Proc Electric Power Applications . 1996; 143(3):231–241p. Cite this Article Gargi Mishra, Ramit Mohan, Kartik Kapoor et al. Generation of Wind Power using Doubly Fed Induction Generator . Research & Reviews: Journal of Physics . 2018; 7(3): 73–78p.