Journal of Power Electronics and Power Systems

Harmonic Compensation in Grid Interconnected DG Units by Closed Loop Control

  1. Prachi Jeevane ✉
  2. Asha Gaikwad

Abstract

This paper deals with improvement of power quality problem namely harmonic problem using distributed generation as their source of electricity. The harmonics occur in such a system because of the nature of loads connected. There are many power quality problems; out of which harmonics normally caused by nonlinear loads like variable frequency drives, fluorescent lightning, office computers etc. have adverse effects on the power quality. Also, harmonic detection and prediction is of utmost importance because it can cause electrical noise, sensitive equipment malfunctioning, tripping of circuit breakers etc. Reduction of harmonics is considered very important for the proper functioning of the customer equipment. There may be many harmonic mitigation techniques including active and passive methods, and choosing the best method out of it may be a challenging task. Proposed method is for single phase inverter for DG systems that requires power quality features like harmonic and its compensation for grid connected operation. Here simulation results in DG and grid connected mode is shown. An active harmonic compensation technique by using current controlled technique has been discussed in this paper, which is basically a closed loop control technique which will eliminate the DG current tracking errors. The effectiveness of the harmonic compensation scheme developed has been verified by the simulation and hardware developed for 1-phase system. The harmonics caused by the nonlinear loads has been compensated by using closed loop control, in which the harmonic current frequency variation is taken as closed loop or given as a feedback to the microcontroller, which in turns gives the pulses to the driver circuit and the driver circuit gives the switching pulses to the gate of the MOSFETS, which is known as PWM technique and this is how harmonics are eliminated in the system. The simulation has been carried out in Matlab 2013. The simulation deals with the PQ theory based PI controller which minimizes the harmonics generated by nonlinear loads. The simulation and hardware results obtained validate this technique. Keywords: Distributed generation, harmonics, MATLAB/simulinkCite this ArticleAsha Gaikwad, Prachi Jeevane. Harmonic Compensation in Grid Interconnected DG Units by Closed Loop Control. Journal of Power Electronics and Power Systems. 2017; 7(1): 9–17p.

References (14)

  1. IEEE Standard 1159 -1995. IEEE Recommended Practice for Monitoring Electric Power Quality. 1995.
  2. Jinwei He, Yun Wei Li, Frede Blaabjerg, et al. Active Harmonic Filtering Using Current-Controlled, Grid -Connected DG Units With Closed -Loop Power Control . IEEE Trans Power Electron . Feb 2014; 29(2): 642–653p.
  3. Bojoi RI, Griva G, Bostan V, et al. Current Control Strategy of Power Conditioners Using Sinusoidal Signal Integrators in Synchronous Reference Frame. IEEE Trans Power Electron. Nov 2005; 20(6): 1402– 1412p.
  4. Francisco De la Rosa . Harmonics and Power System. Taylor & Francis Group ; 2006.
  5. Bose Bimal K. Power Electronics and Motor Drives. Elsevier Inc.; 2006.
  6. Ali E, Abdolhosein N, Bekiarov Stoyan B. Uninterrutible Power Supplies and Active Filters. CRC Press LLC; 2005.
  7. Bojoi RI, Limongi LR, Roiu D, et al. Enhanced Power Quality Control Strategy for Single -Phase Inverters in Distributed Generation Systems. IEEE Trans Power Electron. Mar 2011; 26(3): 798–806p.
  8. He J, Li YW, Munir S. A Flexible Harmonic Control Approach through Voltage Controlled DG-Grid Interfacing Converters. IEEE Trans Ind Electron. Jan 2012; 59(1): 444–455p.
  9. Miret J, Castilla M, Matas J, et al. Selective Harmonic-Compensation Control for Single- Phase Active Power Filter with High Harmonic Rejection . IEEE Trans Ind Electron. Aug 2009; 56(8): 3117–3127p.
  10. Timbus A, Liserre M, Teodorescu R, et al. Evaluation of Current Controllers for Distributed Power Generation Systems . IEEE Trans Power Electron. Mar 2009; 24(3): 654–664p.
  11. Lascu C, Asiminoaei L, Boldea I, et al. High Performance Current Controller for Selective Harmonic Compensation in Active Journal of Power Electronics & Power Systems Volume 7, Issue 1 ISSN: 2249-863X (Online), ISSN: 2321-4244 (Print) JoPEPS (2017) 9-17 © STM Journals 2017. All Rights Reserved Page 17 Power Filters. IEEE Trans Power Electron. May 2007; 22(5): 1826–1835p.
  12. Emanuel Alexander E, Orr John A, David Cyganski, et al. A Survey of Harmonic Voltages and Currents at Distribution Substations. EFE Trans Power Delivery . Oct 1991; 6(4).
  13. Ahmad Jamshidi, Masoud Barakati S, Mohammad Moradi Ghahderijani . Power Quality Improvement and Mitigation Case Study Using Distributed Power Flow Controller. 2012 IEEE.
  14. Asha Gaikwad, Prachi Jeevane. Simulation Results of Harmonic Compensation by Using PQ Based PI Controller for Grid Connected Current Controlled DG Unit . Trends in Electrical Engineering. 2016; 6(2). Cite this Article Asha Gaikwad, Prachi Jeevane. Harmonic Compensation in Grid Interconnected DG Units by Closed Loop Control. Journal of Power Electronics and Power Systems. 2017; 7(1): 9–17p.

Read more of it