Search
16 articles for “isopropyl alcohol”
-
Effect of PMMA Micropillars on the Surface-Driven Capillary Flow of Dyed Aqueous Isopropyl Alcohol in PMMA Microfluidic Devices
Abstract: In this work, dyed aqueous isopropyl alcohol [60% isopropyl alcohol (IPA), 40% dyed water] is prepared as the working liquid. The effect of surface modification on the microfluidic flow of aqueous isopropyl alcohol (IPA) is studied in the polymethylmethacrylate (PMMA) microfluidic devices. The effect of surface area to volume ratio on microfluidic flow of aqueous isopropyl alcohol is also studied. The effect of microfluidic friction on microfluidic flow of aqueous …
Published in Journal of Catalyst & Catalysis · Vol. 6, Issue 2, 2019 · pp. 44–47 Read article
-
Microfluidic Flow of the Dyed Aqueous Isopropyl Alcohol in a single SU-8 based Glass Microfluidic Device Fabricated inside the Cleanroom Laboratory
Abstract: A single SU-8 based glass microfluidic device is fabricated by maskless lithography and indirect bonding technique, using author’s own hands-on completely inside the cleanroom laboratory. Dyed aqueous isopropyl alcohol (90% dyed water, 10% isopropyl alcohol) is the prepared working liquid in this work. The surface-driven microfluidic flow of working liquid is recorded by a CMOS camera catching 25 frames per second with a corresponding time-scale resolution of 0.04 second. The …
Published in Journal of Catalyst & Catalysis · Vol. 6, Issue 1, 2019 · pp. 10–13 Read article
-
Novel Poly (Methyl Cellulose-G-Acrylamide)/Sodium Alginate Based Zeolite 4A Filled Mixed Matrix Membranes for The Separation of Water-Isopropyl Alcohol Mixtures by Pervaporation
Abstract: The Filled blend matrix membranes of (Methyl Cellulose-g-Acryl amide)/Sodium Alginate {(MC-g-AAm)/NaAlg} prepared via solution casting method by in situ incorporation with 4A zeolite particles in 5, 10 and 15 mass % with respect to the weight of (MC-g-AAm)/NaAlg membrane. Several analytical tools such as scanning electron microscope (SEM), atomic force microscope (AFM), Fourier transform infrared spectroscopy (FTIR), X-ray powder diffraction (XRD), X-ray photoelectron spectroscopy (XPS), and thermo-gravimetric analysis (TGA) were …
Published in Journal of Polymer & Composites · Vol. 13, Issue 4, 2025 · pp. 131–152 Read article
-
Surface-Driven Capillary Flow of AqueousIsopropyl Alcohol in the Sudden Expansion PMMA Microchannels
Abstract: Author has fabricated the PMMA sudden expansion microchannels by the maskless lithography, hot embossing lithography, drilling, direct bonding and chip separation technique. The effect of channel aspect ratio on the surface-driven capillary flow is studied in the sudden expansion microchannels fabricated by PMMA as a polymeric material. Also, the effect of surface wettability on the surface-driven capillary flow is studied in the sudden expansion microchannels fabricated by PMMA. This study …
Published in Emerging Trends in Chemical Engineering · Vol. 4, Issue 2, 2017 · pp. 1–4 Read article
-
Role of Solid Acid Catalyst in Isopropylation Reaction
Abstract: Cumene synthesis was carried out by the reaction of benzene with isopropyl alcohol in the vapour phase over rare earth metal modified 13X zeolite. Zeolite modification was done by exchanging sodium ions of the zeolite with cerium ions to vary the acidity of the catalyst in the range of 0.25‑1.36 meq/g. The synthesis was carried out over a wide range of operating conditions. The synthesis conditions were optimized by studying …
Published in Journal of Catalyst & Catalysis · Vol. 2, Issue 2, 2015 · pp. 19–26 Read article
-
Passive Capillary Flow of Aqueous Working Liquids in the PMMA Microfluidic Devices and SU-8 based Glass Microfluidic Devices
Abstract: Abstract: In this work, total 9 individual polymeric microfluidic devices are fabricated. The passive capillary flows of aqueous working liquids are studied in the fabricated polymethylmethacrylate (PMMA) microfluidic devices and SU-8 based glass microfluidic devices. All the microfluidic devices are fabricated inside the cleanroom laboratory. Dyed aqueous ethanol and dyed aqueous isopropyl alcohol (IPA) are the selected working liquids. CMOS camera is used to record each passive capillary flow in …
Published in Recent Trends in Fluid Mechanics · Vol. 6, Issue 1, 2019 · pp. 23–28 Read article
-
Effect of Chlorhexidine Gluconate before Peripheral Intravenouscannulation on Phlebitis
Abstract: Phlebitis is one of the most common complications of peripheral inserted catheter that may occur in upto 75% of hospitalized patients. The center for disease control and prevention guidelines recommend a 2% chlorhexidine-based preparation, tincture of iodine, iodophor or 70% isopropyl alcohol for skin antisepsis prior to insertion of intravenous catheters. The present study was conducted to assess the effect of ‘2.5% chlorhexidine gluconate with 70% ethyl alcohol’ before peripheral …
Published in Journal of Nursing Science & Practice · Vol. 2, Issue 1, 2012 · pp. 58–65 Read article
-
Effect of Chlorhexidine Gluconate before Peripheral Intravenouscannulation on Phlebitis
Abstract: Phlebitis is one of the most common complications of peripheral inserted catheter that may occur in upto 75% of hospitalized patients. The center for disease control and prevention guidelines recommend a 2% chlorhexidine-based preparation, tincture of iodine, iodophor or 70% isopropyl alcohol for skin antisepsis prior to insertion of intravenous catheters. The present study was conducted to assess the effect of ‘2.5% chlorhexidine gluconate with 70% ethyl alcohol’ before peripheral …
Published in Journal of Nursing Science & Practice · Vol. 2, Issue 1-3, 2012 · pp. 58–65 Read article
-
Formulation and Evaluation of a Natural Excipients-Based Diclofenac Sodium Topical Ointment
Abstract: The present study reports the formulation and evaluation of a diclofenac sodium topical ointment incorporating natural excipients to improve skin compatibility and formulation sustainability. Conventional topical non-steroidal anti-inflammatory drug (NSAID) formulations frequently rely on synthetic excipients that may cause dermal irritation and pose environmental concerns. To address these limitations, a 1% w/w diclofenac sodium ointment was developed using aloe vera gel, glycerin, xanthan gum, peppermint oil, vitamin E, and isopropyl …
Published in Research & Reviews: A Journal of Drug Formulation, Development and Production · Vol. 13, Issue 2, 2026 · pp. 14–26 Read article
-
Passive Capillary Flow of Aqueous Working Liquids in the SU-8 based Microchannel Bends
Abstract: In this work, total 4 individual SU-8 based microchannel bends are fabricated by maskless lithography and indirect bonding technique. The leakage-free surface-driven capillary flow of aqueous ethanol is recorded by a CMOS camera. Also, the leakage-free surface-driven capillary flow of aqueous isopropyl alcohol (IPA) is recorded by the CMOS camera. This work will be useful in bioengineering applications.
Published in Emerging Trends in Chemical Engineering · Vol. 5, Issue 1, 2018 · pp. 20–22 Read article
-
An Experimental Study of Spherical Agglomeration of Benzoic acid And Influence of Process Parameters
Abstract: Through the process of drowning-out crystallisation in three partly miscible solvent mixtures, sphere aggregates of benzoic crystal have been successfully created. The mixture of benzoic acid, isopropyl alcohol, and bridging liquid is supplied to an agitated crystallizer with water acting as the anti-solvent. When a substance crystallises, little crystals are formed, and the bridging liquid causes the crystals to group together. Different solvents are utilised because benzoic acid crystals wettably …
Published in Emerging Trends in Chemical Engineering · Vol. 9, Issue 2, 2022 · pp. 19–28 Read article
-
Passive Capillary Flow of Aqueous Working Liquids in the PMMA Microchannel Bends
Abstract: In this work, passive capillary flows or surface-driven capillary flows are recorded in polymethylmethacrylate (PMMA) microfluidic devices using aqueous ethanol and aqueous isopropyl alcohol (IPA) as chosen aqueous working liquids. Microchannel bends are the chosen microfluidic devices with the selected microchannel widths of 50, 120 and 200 micron. This work will be useful to fabricate the PMMA laboratory-on-a-chip systems for bioengineering applications.
Published in Journal of Catalyst & Catalysis · Vol. 5, Issue 1, 2018 · pp. 21–24 Read article
-
Experimental Studies on the Passive Capillary Flow of Non-aqueous Working Liquids in PMMA Microfluidic Devices of Rectangular Cross-Sections
Abstract: The polymethylmethacrylate (PMMA) microfluidic devices are fabricated by the maskless lithography, hot embossing lithography and direct bonding technique. The effects of liquid viscosity, surface wettability and channel aspect ratio on the surface-driven capillary flow of non-aqueous working liquids are studied in the fabricated PMMA microfluidic devices. The working liquids are ethylene glycol, isopropyl alcohol (IPA) and ethanol. These experimental studies will be useful to manipulate different non-aqueous working liquids inside …
Published in Journal of Polymer & Composites · Vol. 5, Issue 2, 2017 · pp. 29–33 Read article
-
Passive Capillary Flow of Aqueous Working Liquids in the Straight PMMA Microchannels of Rectangular Cross- sections
Abstract: In this report, polymethylmethacrylate (PMMA) is used to fabricate the straight microchannels of uniform channel widths having rectangular cross-sections. Maskless lithography, hot embossing lithography and direct bonding are the chosen techniques to fabrication the straight PMMA microchannels. Aqueous ethanol and aqueous isopropyl alcohol (IPA) are the prepared aqueous working liquids to study the passive capillary flow characteristics. Total 8 individual straight PMMA microchannels are fabricated in this work. This work …
Published in Journal of Petroleum Engineering & Technology · Vol. 8, Issue 2, 2018 · pp. 5–8 Read article
-
Report on Microfluidic Flow of Dyed Working Liquids inside the Polymeric Devices
Abstract: In this experimental work, a single SU-8 based glass microfluidic device is engineered by the maskless lithography and indirect bonding technique. Also, total nine individual polymethylmethacrylate (PMMA) based microfluidic devices are fabricated by maskless lithography, hot embossing lithography, and direct bonding technique. Dyed ethylene glycol, dyed ethanol, and dyed aqueous isopropyl alcohol (50% water, 50% IPA) are prepared and used as working liquids to record each surface-driven microfluidic flow. The …
Published in Journal of Thin Films, Coating Science Technology & Application · Vol. 8, Issue 1, 2021 · pp. 22–29 Read article
-
Phytochemical Quantification of Characteristics of Plant Extracts in Acidic Medium on Metal Inhibition
Abstract: Carbon steel coupon or specimen was analysed using X-ray Fluorescence Spectroscopy in determining the coupon’s composition and weighed before its total immersion into the acidic environment and acidic environment with different inhibitors (extract) respectively of different of concentration for a monitoring period of five day (120 hours). Corrosion inhibitive effect of moringa oleifera leaf (MOL), carrica papaya leaf (CPL) and coconut coir dust (CCD) extract respectively in mitigating the corrosion …
Published in Journal of Petroleum Engineering & Technology · Vol. 13, Issue 1, 2023 · pp. 32–43 Read article