Search
35 articles for “evaporative condenser”
-
Experimental Investigation on Performance of Vapor Compression Refrigeration System using Nanorefrigerant (R134a+Al2O3) with/without Evaporative Condenser
Abstract: In traditional refrigeration system the main focus of researchers is always to improve its performance by reducing work of compression and enhancing the heat transfer rate in different heat exchangers and this can be achieved by adopting suitable technique. In this research work experiment is carried out on vapor compression refrigeration test rig using nanorefrigerant of R134a as base refrigerant and nanoparticles of aluminium oxide Al2O3 in different concentration so …
Published in Journal of Refrigeration, Air conditioning, Heating and ventilation · Vol. 7, Issue 3, 2020 · pp. 1–8 Read article
-
Design of Evaporator and Condenser for Solar Adsorption Refrigeration System
Abstract: Solar adsorption refrigeration systems provide a promising alternative for sustainable cooling in regions with limited grid access and high solar availability because they can convert low-grade thermal energy into refrigeration without mechanical compression. The performance of such systems depends strongly on the thermal behavior of the evaporator and condenser, since these components govern the refrigerant evaporation rate, condensation effectiveness, and overall cycle stability. This paper presents focus on the design …
Published in Journal of Refrigeration, Air conditioning, Heating and ventilation · Vol. 13, Issue 2, 2026 · pp. 1–10 Read article
-
Application of Refrigerator and Heat Pump Operated by Solar Photovoltaic Modules for Room Air Conditioning in Kolkata City
Abstract: India is a hot climatic country there is an urgent need for refrigeration mainly in May (the hottest month),March, and September (moderate hot), and also a heating requirement for cold weather (January). The present work deals with the air refrigeration in Kolkata city of a room maintained at 15oC in May(hottestmonth)(with evaporator temperature (12oC), condenser temperature (38oC)), at 20oC in March (with evaporator temperature (18oC), condenser temperature (36oC)) ,at 22oC …
Published in Journal of Refrigeration, Air conditioning, Heating and ventilation · Vol. 9, Issue 2, 2022 · pp. 11–23 Read article
-
Modelling and Simulation of a Combined System Geothermal Binary Plant and Parabolic Solar Concentrator
Abstract: The present work describes a new prototype that uses the concentrated solar radiation to improve the performance of geothermal power plants. Current methods of heat recovering have been used to reduce the amount of fossil fuel used to produce vapor or to increase gas pressure and temperature, depending on the type of system; however, concentrated solar energy is an unknown resource that may help to increase vapor production at a …
Published in Journal of Thermal Engineering and Applications · Vol. 8, Issue 1, 2021 · pp. 23–46 Read article
-
Dynamic Simulation of Load-Responsive Vapor Compression Refrigeration Systems
Abstract: Because of their dependable operation and effectiveness, vapor compression refrigeration systems, or vapor compression refrigeration (VCRS), have become popular in commercial, industrial, and residential settings. However, under different thermal loads, classic vapor compression refrigeration (VCR) systems may perform less well in that they are usually built for steady-state conditions and run at consistent speeds. In order to improve a load-responsive VCR system’s flexibility, energy efficiency, and response to changing cooling …
Published in Journal of Refrigeration, Air conditioning, Heating and ventilation · Vol. 12, Issue 2, 2025 · pp. 32–37 Read article
-
Experimental and CFD Analysis on a Hybrid Cooler
Abstract: AbstractSince the invention of air conditioners, it has been used widely all over the world. The harmful effects of ACs cannot be ignored as far as the environment is concern. AC being widely used, needs a suitable alternative for sustainable goals to be achieved. Air conditioning with the help of forced ventilation system is studied in this research work. Its implementation and effects on the room temperature is studied in …
Published in Journal of Thermal Engineering and Applications · Vol. 6, Issue 3, 2019 · pp. 1–8 Read article
-
Modeling and Simulation of Heat and Mass Exchanges in Refrigerated Compartment of a Truck
Abstract: This paper presents a numerical model to simulate, in dynamic regime, the heat and mass exchanges in refrigerated compartment of a truck coupled with its refrigeration machine. The model of the refrigerated compartment developed, is based on mass and energy balances of the air inside the compartment. Heat exchanges through the walls, including the thermal bridges, are calculated. Another sub-model determines the heat and humidity exchanges during the door openings. …
Published in Journal of Refrigeration, Air conditioning, Heating and ventilation · Vol. 2, Issue 1, 2015 · pp. 21–29 Read article
-
A Review on Ejector Based Refrigeration System
Abstract: Abstract Development of industry and increasing living quality, there is a continuous increase in demand of energy which has led to serious environmental issues like global warming, air pollution, production of toxic gases, ozone layer depletion, etc. High oil prize is motivating the researchers to search into renewable energy alternatives. Energy supply to the refrigeration and air conditioning system constitutes a significant role in the world. So, it is very …
Published in Journal of Refrigeration, Air conditioning, Heating and ventilation · Vol. 3, Issue 2, 2016 · pp. 8–36 Read article
-
Experimental Evaluation of Environmental Friendly and Low Global Warming Refrigerants as an Alternative Option for Window Air Conditioning System
Abstract: This paper presents an experimental evaluation and performance comparison of window air-conditioning system with R-410A and R32 and to compare with HCFC-22 refrigerant. The base line test is performed with 2 “Ton of Refrigeration” (TR) capacities air conditioner, with evaporator temperature of 7.2 °C and condenser temperature of 54.4 °C. The coefficient of performance (COP) of the refrigerants R32, R22 and R410A are 3.81, 3.15 and 2.17 respectively simulated; it …
Published in Journal of Refrigeration, Air conditioning, Heating and ventilation · Vol. 1, Issue 3, 2014 · pp. 7–13 Read article
-
Design Fabrication and Testing of Hydraulic Oil Cooler by Using Heat Pipe
Abstract: Heat pipe is an essentially passive heat transfer device having high thermal conductivity. In hydraulic power pack use of traditional shell and tube heat exchanger would require lot of space, more power and maintenance cost. So heat pipe device is easily implemented for cooling of hydraulic oil. The heat pipe equipped hydraulic oil cooler uses a heat pipe module comprises of aluminum base block with oil channels machined on it. …
Published in Journal of Refrigeration, Air conditioning, Heating and ventilation · Vol. 5, Issue 1, 2018 · pp. 10–19 Read article
-
Exergy Analysis of Vapor Compression Refrigeration System with Refrigerants R134a, R152a, R290 and R32
Abstract: Abstract This paper pressents exergy analysis of vapour compression refrigeration system with refrigerants R134a, R152a, R290and R32. This analysis helps to understand the effect of irreversibility on thermodynamic processes. It shows exergy losses in different components of the system and hence leads to improve the performance of different components of the system. A computational model has been developed to study the effects of evaporator temperature and condenser temperature on COP, …
Published in Journal of Refrigeration, Air conditioning, Heating and ventilation · Vol. 2, Issue 3, 2015 · pp. 11–19 Read article
-
Performance and Exergy Loss Analysis for a Single Slope Solar Still Using PMMA
Abstract: A solar still constructed using polymethyl methacrylate (PMMA) represents an improved approach to solar desalination, in which conventional materials such as metal or concrete are substituted or reinforced with PMMA- based composites PMMA sheets are often used as the transparent glazing cover of the solar still instead of glass. It allows maximum solar radiation to pass into the basin, heating the saline/brackish water effectively. A tubular solar still made from …
Published in Journal of Polymer & Composites · Vol. 14, Issue 3, 2026 · pp. 799–807 Read article
-
VACUUM ASSISTED ABSORPTION CHILLER. PART I: MODELING AND SIMULATION
Abstract: A new absorption chiller assisted by a vacuum device has been simulated and characterized through a simulation process. Simulation has been developed for a range of 0.75-10 bars for the evaporation process with a constant ratio between the condensation and evaporation pressure of 10. Simulation has predicted a great improvement of the COP of the absorption chiller when operating at evaporation pressures under atmospheric level, with values of 6.844 for …
Published in Journal of Refrigeration, Air conditioning, Heating and ventilation · Vol. 8, Issue 3, 2021 · pp. 1–11 Read article
-
Performance Improvement of Air Cooled Condenser of Split Air Conditioner: A Study
Abstract: Abstract Running residential or commercial split type air-conditioners plays a vital role for increasing electrical energy consumption in large quantity. While considering the performance of air conditioning system or specific energy consumption which is to be considered, as a function of condenser, compressor and evaporator performance respectively. By improving the heat transfer efficiency of the condenser performance improvement can be achieved, which helps in reducing electrical consumption. In the present …
Published in Journal of Refrigeration, Air conditioning, Heating and ventilation · Vol. 3, Issue 3, 2016 · pp. 35–44 Read article
-
Design, Fabrication and Testing of Ejector for Solar Thermal Cooling System
Abstract: The Solar Thermal Cooling System mainly comprises of Solar Panels, Generator, Condenser and Evaporator. In addition an ejector is mounted in the existing system to improve the performance of the system. The Ejector is having a primary and secondary inlet nozzle. In the primary flow nozzle the motive refrigerant will flow with high pressure which comes from generator. The area of the ejector is reduced to increase the pressure by …
Published in Journal of Refrigeration, Air conditioning, Heating and ventilation · Vol. 7, Issue 1, 2020 · pp. 12–20 Read article
-
Designing and CFD Analysis of Table Top Refrigerator Hexagonal Coil Crossection
Abstract: In the Present study CFD analysis has been performed on evaporator unit. Tabletop refrigerators are the common house hold unit used in almost all houses. Evaporator and Condenser unit is the main functioning unit of refrigerator system used for the cooling applications. With the increase of modernization use of refrigerator system has rapidly increases due to the reason a lot of researches are prevailing on refrigerator systems. With the updating …
Published in Journal of Thermal Engineering and Applications · Vol. 6, Issue 2, 2019 · pp. 34–51 Read article
-
Modification In Technology of Solar Water Distillation for Improving Performance Through Design of Rotating Cylinder
Abstract: A solar still uses sunlight to turn salty or dirty water into clean drinking water by evaporation and condensation. It is one of the best solutions for drinking water shortages and environmental issues, as well as being affordable and friendly to the ecosystem. The primary issue with using traditional solar power is still how inefficient it is. Prominent goal of experiment is to do alteration in existing solar still. A …
Published in Journal of Polymer & Composites · Vol. 13, Issue 3, 2025 · pp. 398–404 Read article
-
An Exergetic based Assessment of Biogas as an Energy Source in a Hybrid Refrigeration System
Abstract: The analysis of biogas operated Ammonia-Water vapor compression absorption (hybrid) refrigeration system was carried out based on computational model being developed and the thermodynamic properties of working fluids have been used from the computer code. The variation of performance parameters such as exergy loss, COPCOOLING, COPHEATING and Exergy efficiency are studied with varying generator temperature, evaporator temperature, condenser and absorber temperature. The results indicate that maximum COP cooling as well …
Published in Journal of Refrigeration, Air conditioning, Heating and ventilation · Vol. 1, Issue 2, 2014 · pp. 31–40 Read article
-
Exergetic Analysis of Single Effect LiBr-Water Absorption Cooling System
Abstract: Abstract This paper presents the exergy analysis of single effect LiBr-Water absorption cooling system. The work is committed to the study, the evaluation and distribution of the destroyed exergy for each component constituting this kind of system. The thermodynamic models, derived using the first and second laws of thermodynamics, are employed in a computer program using the engineering equation solver (EES) software to perform the calculations. Influence of various operating …
Published in Journal of Refrigeration, Air conditioning, Heating and ventilation · Vol. 3, Issue 2, 2016 · pp. 41–48 Read article
-
Mathematical Study and Steady-State Modeling of Simple Vapour Adsorption Refrigeration System
Abstract: Abstract This paper discusses the mathematical formulation for various heats involved during different processes of a simple vapour adsorption refrigeration cycle having activated carbon and methanol as the active working pairs. This formulation is further used and a detailed analysis of the cycle’s performance is studied based on a steady-state model prepared on the FORTRAN77 platform compiler. The analysis includes effects of the input parameters of the cycle such as …
Published in Journal of Refrigeration, Air conditioning, Heating and ventilation · Vol. 3, Issue 3, 2016 · pp. 1–13 Read article