Advancements in Polymeric Capillary Materials for Chromatographic Applications
Abstract: Traditionally, glass capillaries have been the material of choice due to their inertness, transparency, and precision in delivering small sample volumes. However, glass capillaries have significant drawbacks, including fragility, limited flexibility, and difficulties in modification for specialized applications. Recent advancements in polymer chemistry have introduced novel polymeric capillary materials that offer several advantages over conventional glass capillaries. Additionally, they exhibit enhanced durability and resistance to a broad range of chemicals, …
Published in Journal of Polymer & Composites · Vol. 13, Issue 4, 2025 · pp. 137–144 Read article
-
Techno-economic Assessment of a Domestic Refrigerator with Aluminium-based Suction Line and Capillary Tube
Abstract: The present work reports the experimental performance evaluation of aluminum suction line-based domestic refrigerators. Furthermore, it compared domestic refrigerators with conventional copper capillary tubes and suction lines using R600a as a refrigerant. Performance parameters: energy consumption, ice-making time, and pull-down time was reduced significantly compared to conventional copper suction and capillary tube. Refrigerants having Ambient temperature for ice making test and pull down were initially set at 43°C and that …
Published in Journal of Polymer & Composites Read article
-
Short Review on the Flow and Filtration of Polystyrene Microparticles in Micron-Scale Fluid Mechanics towards the Applications related to fluidic Microelectromechanical Systems
Abstract: Maskless lithography, hot embossing lithography and direct bonding technique are useful to fabricate the polymethylmethacrylate (PMMA) microfluidic devices. Also, maskless lithography and indirect bonding technique are useful to fabricate the SU-8 based glass microfluidic devices. In this work, a short review on microfluidic flow and microfluidic filtration of microparticles is provided by author related to the micron-scale fluid mechanics. This review may be useful to perform the blood filtration in …
Published in Journal of Microelectronics and Solid State Devices Read article
-
Short Report to Describe the Surface-driven Microfluidic Flow in Fluid Mechanics
Abstract: In this short report, a brief review on surface-driven microfluidic flow is provided. Also, the maskless lithography and indirect bonding technique are used to fabricate a single SU-8 based glass microfluidic device. Dyed ethylene glycol is prepared as working liquid to test the fabricated device. The surface-driven microfluidic flow of dyed ethylene glycol is recorded by a CMOS camera catching 25 frames per second with a corresponding time-scale resolution of …
Published in Recent Trends in Fluid Mechanics Read article
-
Chemiluminescence: Recent Developments and Photochemical Applications in Analytical Chemistry
Abstract: Chemiluminescence (CL) is the observable production of electromagnetic radiation from a chemical reaction, typically in the form of ultraviolet, visible, or infrared light. According to subjective yield, CL has either been directly emitted from electronically excited intermediate products, or it has been supported by another molecule to emit CL. Since the 1950s, CL has been supported as a valid analytical tool, with the descriptive issued scope being limited to content …
Published in International Journal of Photochemistry and Photochemical Research · Vol. 2, Issue 1, 2024 · pp. 20–25 Read article
-
Semiconductor Physics and Micron Scale Fluid Mechanics towards the Microelectromechanical Systems Associated with Nanotechnology
Abstract: Interrelations among semiconductor physics, microfluidics, nanofluidics and nanotechnology are briefly described. A single microchannel bend is designed and fabricated by author using the maskless lithography, hot embossing lithography and direct bonding. Dyed water is the selected and prepared working liquid in this work. Surface-driven (passive) capillary flow of working liquid is recorded in the fabricated microchannel bend using a CMOS camera. This work may be useful in applied chemistry.
Published in Research & Reviews : Journal of Physics Read article
-
A Ponder & Sedulousness Of Legion Shale Stabilizing Materials In Aqueous Based Drilling Fluid During The Process Of Borehole Strengthening
Abstract: Drilling fluid used while drilling the layers of shale will have the potential of reacting with water which tends to increase stickiness, induce swelling and promote sloughing of the borehole. This results in the reduction of drilling fluid circulation, increased mud loss, increase in torque and drag, reduction in lubricity. This will ultimately result in the increase of Non-Productive Time (NPT) during drilling which in turn increases Capital Expenditure (CAPEX) …
Published in International Journal of Pollution: Prevention & Control · Vol. 1, Issue 2, 2023 · pp. 35–40 Read article
-
Amlodipine induced peripheral edema and gingivitis – A case report.
Abstract: Calcium channel a group of drugs used to treat heart disorders are called blockers. These drugs dilate blood vessels and improve blood flow to heart, these works by preventing calcium flow through ion -specific (L- type) calcium channels in the cell membrane. Amlodipine, a calcium channel blocker in the dihydropyridine class, can cause peripheral edema and drug-induced gingivitis in some patients. In this case, the patient experienced swelling in the …
Published in International Journal of Tropical Medicines · Vol. 2, Issue 1, 2025 · pp. 45–49 Read article
-
A Sensitive SPE-ECD-GLC Procedure for Analyzing Simazine Quantitatively in Food Products
Abstract: Short and simple solid-phase extraction (SPE) method interfacing and hyphenating gas liquid chromatographic-electron capture detection (GLC-ECD) method has been developed for the qualification and quantification of simazine in some daily used agro products. United States Pharmacopeia G-42 gas chromatography stationary phase with ZB-35a, HTb Inferno-cZ (Zebron, Za) capillary column with an enlarged and extended temperature range of –60° to 400°C and electron capture detector was selected correlating some chemical, physical …
Published in International Journal of Biochemistry and Biomolecule Research · Vol. 3, Issue 1, 2025 · pp. 20–27 Read article
-
A Comprehensive Review on the Miniaturized Analytical Techniques for Sustainable Pharmaceutical Testing
Abstract: Miniaturized analytical techniques are revolutionizing pharmaceutical testing by offering sustainable and efficient alternatives to traditional methods. These techniques are designed to reduce sample and reagent consumption, minimize waste generation, and accelerate analysis, aligning perfectly with the principles of green analytical chemistry. This comprehensive review aims to thoroughly explore the landscape of miniaturized analytical techniques, specifically highlighting their profound impact on fostering sustainable practices within the pharmaceutical sector. The review systematically …
Published in Research and Reviews: A Journal of Pharmaceutical Science · Vol. 17, Issue 1, 2026 · pp. 18–39 Read article
-
Hydrolysis-Driven Optimization of Hydroxypropyl Maize Starch for Improved Micro-Pellet Binding and Quick Solubility of Spirulina-Based Micro-Pellets
Abstract: Acid hydrolysis is a well-established approach for modifying the physicochemical properties of polysaccharides & macromolecules including hydroxypropyl Maize starch (HPMS). In this study, the effect of varying concentrations of hydrochloric acid on the partial hydrolytic degradation of HPMS (Lycoat RS-780) was investigated at 85°C for 4 h, yielding polymers of different molecular weights. The Acid-mediated degradation effects on polymer characteristics were systematically assessed using capillary viscometry and gel permeation chromatography …