Search
291 articles for “SEI”
-
Comprehensive Approaches to Seizure Control: Home Care & Hospital Care
Abstract: Seizures show up as sudden, uncontrollable brain electrical abnormalities. Those afflicted by this health issue can suffer greatly and usually call for quick and thorough treatment. Examining several facets of seizure control, including disease epidemiology, etiology, clinical presentation, categorization, as well as acute and long-term therapy techniques, this review. Furthermore, emphasized in the review are several new trends that might help with seizure control. Factors including CNS infections, metabolic abnormalities, …
Published in Research and Reviews : A Journal of Medical Science and Technology · Vol. 14, Issue 1, 2024 · pp. 30–34 Read article
-
Seismic-Resilient Structural Systems: Geotechnical Engineering
Abstract: Earthquakes represent one of the most destructive natural hazards, capable of causing severe structural damage, loss of life, and substantial economic disruption. Seismic waves propagating through the ground can induce excessive forces and deformations in buildings, often leading to partial or complete collapse. Statistical records indicate that thousands of earthquakes occur globally each year, including several major events that result in significant damage. Past earthquake disasters have repeatedly demonstrated that …
Published in Journal of Geotechnical Engineering · Vol. 13, Issue 1, 2026 · pp. 55–63 Read article
-
Performance Based Seismic Evaluation of G+12 RCC Structures in Seismic Zone IV with and without Corner Shear Walls Considering Soil Types I, II, and III
Abstract: Seismic behavior of multi-storey buildings is significantly influenced by structural stiffness and supporting soil conditions. This study investigates the seismic response of a G+12 reinforced concrete building by comparing two structural configurations, namely buildings with shear walls and buildings without shear walls, under three soil conditions: Type I, Type II, and Type III soils. The analysis is carried out using the response spectrum method in accordance with IS 1893 (Part …
Published in Recent Trends in Civil Engineering & Technology · Vol. 16, Issue 2, 2026 · pp. 1–14 Read article
-
Seismic response analysis of adjacent rc structures considering seismic pounding effect
Abstract: As we know there is increase in construction of High-rise structures in developed cities. These structures are subjected to earthquake forces. Due to populated areas the buildings are constructed very closely to each other in order to utilize the entire property area. In such conditions there is possibility of occurring seismic pounding which will cause greater damage to the adjacent structures in addition to the damage caused by the earthquake. …
Published in Journal of Structural Engineering and Management · Vol. 9, Issue 3, 2022 · pp. 9–20 Read article
-
Guidelines for Withdrawal of Anti-Epileptic Drugs in Seizure-Free Patients
Abstract: The ultimate goal of epilepsy treatment is to become seizure free and live a healthy life without the need to take antiepileptic drugs may cause several tricky and sometimes serious side-effects. There is no class I evidence that is based on randomized double-blind trials for withdrawal of antiepileptics in adults who become seizure-free while taking such drugs. Whether or not antiepileptic drugs should be withdrawn after a patient has been …
Published in Research and Reviews: A Journal of Health Professions · Vol. 4, Issue 1, 2014 · pp. 5–8 Read article
-
Seismic Behavior of RCC Buildings under Revised Seismic Zone Classification by BNBC
Abstract: This study aims at the comparison of provisions of earthquake analysis given BNBC 2017. The revised BNBC 2017 has divided the seismic zones of Bangladesh into four different categories such as Zone-1, Zone-2, Zone-3 and Zone-4 respectively. They have different seismic zone coefficients. Finally structural analysis and design of a typical G+10 storey school building situated in all four seismic zones is conducted to investigate the seismic behavior of that …
Published in Recent Trends in Civil Engineering & Technology · Vol. 9, Issue 3, 2019 · pp. 21–28 Read article
-
Seismic Analysis of G+10 Building With and Without Zipper Brace Frame
Abstract: This paper presents a seismic analysis of a G+10 building with and without Zipper Brace Frame (ZBF). The research begins with a detailed literature review, investigating the existing seismic-resistant techniques employed in high-rise buildings. The Zipper Brace Frame is introduced as an innovative system that has shown promising results in enhancing seismic performance while maintaining architectural aesthetics. Two analytical models are created: one without bracing systems and the other incorporating …
Published in Journal of Structural Engineering and Management · Vol. 10, Issue 3, 2023 · pp. 27–34 Read article
-
To Study the VLF Signal for SeismoElectromagnetic Phenomena by Using Wavelet Analysis
Abstract: The research focuses on exploring the potential of Very Low Frequency (VLF) signals as indicators of seismic and geomagnetic activities, particularly in the context of earthquake prediction. It delves into the analysis of VLF data using wavelet-based methodologies and neural networks to detect anomalies preceding seismic events.Observations and analysis of VLF data revealed fluctuations and discrepancies, notably "silent days," occurring several days before seismic events. These irregularities studied through wavelet …
Published in Research & Reviews : Journal of Physics · Vol. 12, Issue 2, 2023 Read article
-
A SEIR-Informed Stacked Fusion of Prophet, XGBoost, and LSTM for Ward-Level Epidemic Forecasting in Amravati Municipal Corporation
Abstract: Municipal epidemic preparedness depends on accurate short-horizon forecasts at fine spatial granularity. Ward-level incidence series are typically nonstationary due to changing contact patterns, interventions, reporting delays, and heterogeneous demographic and environmental factors. This paper presents a mathematically formulated hybrid forecasting architecture designed for Amravati Municipal Corporation (AMC). The method decomposes observed incidence into (i) a mechanistic SEIR baseline that enforces epidemiological structure and (ii) a data-driven residual learned using Prophet …
Published in Research & Reviews: Discrete Mathematical Structures · Vol. 13, Issue 1, 2026 · pp. 17–23 Read article
-
Seismic Analysis of Conventional, Hexagrid and Octagrid Steel Structural Systems
Abstract: The seismic resilience of multi-story buildings in earthquake-prone regions is a critical consideration in structural engineering. This dissertation presents a comprehensive analysis of the seismic performance of proposed multi-story buildings with varying heights (G+10, G+15, and G+20) using conventional, hexagrid, and octagrid structural systems. The study utilizes the Response Spectrum Method under seismic zone Ⅴ conditions to assess key parameters including storey drift, storey displacement, base shear, and overturning moment. …
Published in Journal of Structural Engineering and Management · Vol. 11, Issue 1, 2024 · pp. 26–41 Read article
-
Advancements in Seismic Analysis Based on Shear Walls Composite Materials
Abstract: In this study more than 30 research papers are thoroughly reviewed in the area of Seismic Analysis based on Shear Walls. Seismic performance evaluation is used to assess a construction's seismic behavior in accordance with predetermined performance criteria. These methods have been applied in a number of assessment studies to investigate the seismic behavior of shear wall designs, and their findings have advanced the field overall. Shear wall is works …
Published in Journal of Polymer & Composites · Vol. 12, Issue 5, 2024 · pp. 235–243 Read article
-
Seismic Analysis of G + 10 Rc Frame Building by Using IS 1893, EC 8 & UBC seismic codes.
Abstract: The present study investigates the behaviour of G+10 storey rectangular shaped building provided with water tank at different locations total four model of G+10 storey building are prepared. The seismic of G+10 storey building is carried out by using structural analysis computer program STAAD Pro. The dynamic analysis (Response Spectrum Method) of G+10 storey rectangle shaped building with water tank at a different locations is carried out by using structural …
Published in Journal of Structural Engineering and Management · Vol. 6, Issue 1, 2019 · pp. 47–54 Read article
-
Seismic Analysis of G+30 RCC Frmaed Structure and Use of R.C Jacketing
Abstract: In high-rise buildings, such as G+30 reinforced concrete (RCC) framed structures, key concerns during seismic events include maintaining structural integrity, preventing catastrophic collapse, and ensuring the safety of occupants. Seismic retrofitting is a vital process aimed at enhancing the resilience of such buildings and infrastructure against earthquake forces, by strengthening their ability to withstand seismic activity. This abstract provides an overview of numerous seismic retrofitting projects implemented worldwide, focusing on …
Published in Recent Trends in Civil Engineering & Technology · Vol. 14, Issue 3, 2024 · pp. 20–37 Read article
-
Seismic Hazard Evaluation through Attenuation Law Derivation and Response Spectrum Design: Bangladesh Case Study
Abstract: Bangladesh, positioned at the confluence of the Indian, Eurasian, and Burma tectonic plates, faces significant seismic hazards due to its complex geological setting. This research focuses on formulating empirical attenuation relationships and Creating a design response spectrum for assessing seismic risks in Bangladesh, using data from ten large earthquakes with magnitudes ranging from 6. 7 to 7. 9. The study creates Ground Motion Prediction Equations (GMPEs) for various structural periods …
Published in Journal of Structural Engineering and Management · Vol. 12, Issue 3, 2025 · pp. 54–63 Read article
-
Seismic Response of Braced RC Elevated Water Tanks for Various Seismic Zones
Abstract: In this paper, a reinforced concrete elevated water tank with a capacity of 500 cubic meters and h/d ratio=0.7 is considered, the present study investigate the performance of elevated water tank using dynamic analysis, i.e., Response Spectrum method. The modeling of elevated water tank is carried out by using finite element base software STAAD.Pro. Total twelve number of model were made for empty tank, half tank and full tank condition, …
Published in Journal of Structural Engineering and Management · Vol. 4, Issue 1, 2017 · pp. 43–64 Read article
-
Comprehensive Seismic Evaluation of Underground Water Tanks with Focus on Fill Conditions: An In-Depth STAAD.Pro Analysis
Abstract: The seismic analysis of underground water tanks is crucial for ensuring their structuralintegrity and performance during seismic events. This review paper focuses on the seismicanalysis of underground water tanks considering different fill conditions, utilizing theSTAAD.Pro software for analysis purposes. The significance of seismic analysis in undergroundwater tanks and highlights the importance of considering fill conditions during the analysis.Various fill conditions, such as empty, partially filled, and fully filled tanks, are …
Published in Journal of Structural Engineering and Management · Vol. 10, Issue 3, 2023 · pp. 20–26 Read article
-
Pseudo-Static Limit Equilibrium Method for Bearing Capacity of Footing on Slope and Seismic Uplift Capacity of Horizontal Strip Anchor
Abstract: Seismic bearing capacity for a shallow strip footing embedded in a sloping ground is derived along with seismic uplift capacity of horizontal strip anchors. c-ϕ soil medium is used with limit equilibrium method of analysis. A planar failure mechanism has been adopted. The seismic bearing capacity is determined in the form of a single pseudo-static bearing capacity coefficient (Nγe) in association with unit weight, surcharge and cohesion, which becomes more …
Published in Journal of Geotechnical Engineering · Vol. 6, Issue 3, 2019 · pp. 18–31 Read article
-
COMPARATIVE SEISMIC RESPONSE OF IRREGULAR HIGH-RISE RCC 25 STOREY BUILDINGS WITH AND WITHOUT SHEAR WALLS CONSIDERING P–DELTA EFFECT
Abstract: The seismic performance of high-rise reinforced concrete (RCC) buildings is significantly affected by plan irregularity, lateral stiffness distribution, and second-order (P–Delta) effects. Irregular structural configurations may generate torsional response and increased deformation demand under seismic excitation while geometric nonlinearity further amplifies displacement and internal forces in tall structures . This study presents a comparative seismic assessment of a G+24 storey RCC building having overall plan dimensions of 30,000 mm × …
Published in Journal of Structural Engineering and Management · Vol. 13, Issue 2, 2026 Read article
-
Comparative Performance Assessment of Shear Wall and Diagrid Systems in an Octagonal Tall High-Rise Building under Seismic and Wind Loads
Abstract: The increasing demand for high-rise structures due to rapid urbanization necessitates the adoption of efficient lateral load-resisting systems to ensure structural safety, stability, and serviceability. This study presents a comparative evaluation of the seismic and wind performance of a Ground plus Fiftystorey high-rise building with an octagonal plan, incorporating different structural configurations such as shear wall arrangements and a diagrid system. A total of six analytical models, including a conventional …
Published in Journal of Structural Engineering and Management · Vol. 13, Issue 2, 2026 Read article
-
Group-Theoretic Symmetry Indices for Modular Building Layouts under Seismic Load Redistribution
Abstract: Symmetry in modular buildings operates simultaneously as an architectural language, a structural regularizer, and a computational design variable. This paper develops a group-theoretic framework for evaluating and optimizing plan symmetry in modular buildings subjected to seismic load redistribution. The building layout is modeled as a finite occupancy–stiffness field defined on a rectangular lattice, where each module encodes both mass and stiffness contributions. Planar reflections and quarter-turn rotations are represented as …
Published in Emerging Trends in Symmetry · Vol. 2, Issue 1, 2026 · pp. 01–07 Read article