Search
33 articles for “Harmonic Reduction”
-
Quantum-Inspired Optimization of Multi-Level Power Converter Switching Sequences for Harmonic Reduction
Abstract: The increasing adoption of multilevel power converters in renewable energy systems, electric vehicles, and smart grid applications has created a growing demand for advanced switching optimization techniques capable of minimizing harmonic distortion while maintaining high conversion efficiency. This paper proposes a Quantum-Inspired Optimization (QIO)-based switching sequence generation framework for multilevel power converters to achieve superior harmonic reduction and enhanced power quality. The proposed approach utilizes quantum-inspired probability representation and evolutionary …
Published in Trends in Electrical Engineering · Vol. 16, Issue 3, 2025 Read article
-
A Novel Approach control based Multilevel Inverter Topology Using DC Sources for Harmonic Reduction, Leakage Current Mitigation, and Voltage Stress Minimization in Photovoltaic Applications
Abstract: Photovoltaic systems are becoming main renewable energy sources, but they may face several challenges such as harmonic distortion, leakage current and variable output voltage. Due to this efficiency of the system leads to reduction and also power quality. To overcome these issues the paper presents a novel control-based multi-level inverter(MLI) and it uses multiple DC sources. The main goal of study is to provide a clean, stable and efficient power …
Published in International Journal of Electrical Machine Analysis and Design · Vol. 4, Issue 2, 2026 Read article
-
Comparative Critical Analysis of Control Techniques Optimized using ATS Algorithm and Conventional Control Techniques Applied in Shunt Active Power Filter for Total Harmonic Reduction for Power Electronic Converters in High Frequency (400 Hz) Aircraft Sys
Abstract: Three different conventional control strategies used for extracting reference currents for shunt active power filter and optimization of these strategies using Adaptive Tabu Search have been compared and their performances have been evaluated under different balanced and unbalanced loads connected together. The compensation ability of different control strategies will be compared, and suggestion will be given for optimum. Simulation results using MATLAB have been included. Keywords: Active powers filter (APF), …
Published in Journal of Aerospace Engineering & Technology · Vol. 5, Issue 3, 2015 · pp. 44–52 Read article
-
Integrated Maximum Power Point Tracking and Harmonic Reduction in a Grid Interactive Solar PV Inverter
Abstract: Normal 0 false false false EN-US X-NONE X-NONE A solar photovoltaic (PV) cell exhibits a non-linear i-v characteristic and its maximum power point (MPP) varies with solar insolation and temperature. A dc-to-dc converter is generally employed along with inverter circuit to operate the solar PV system at maximum power point. This adds to the cost, which increases significantly with the size of the system. Moreover, grid-tie inverter employing thyristors has …
Published in Journal of Instrumentation Technology & Innovations · Vol. 4, Issue 1, 2014 · pp. 7–15 Read article
-
Control Strategies for Shunt Active Power Filters in Total Harmonic Distortion Reduction: A Comprehensive Review
Abstract: This paperwork presents a single-phase shunt active power filter to reduce total harmonic distortion.Harmonic pollution in the power system has increased significantly because of the widespread usage of nonlinearsingle phase power electronic equipment on the low voltage side. For electrical engineers, improving powerquality has emerged as their greatest obstacle. A single-phase shunt active power filter was constructed inMATLAB/SIMULINK using a voltage supply inverter and a hysteresis current regulator. The performance …
Published in Recent Trends in Electronics Communication Systems · Vol. 10, Issue 2, 2023 · pp. 30–42 Read article
-
Adaptive Neuro-Fuzzy Inference System (ANFIS) Control for Total Harmonic Distortions Reduction of Multi-Pulse STATCOM
Abstract: In this paper proposed ANFIS System is adapted for controllable mitigation of Total harmonic distortions of STATCOM with Multiple pulse technology. Integrated power electronics device, Gate Turn Off (GTO) is used in switching mode with Voltage source convertor during application of distinct load conditions. The proportional and integrated Controller is replaced by a smart fuzzy logic controller that offers great support for harmonic mitigation by redefining the electrical magnitudes of …
Published in Journal of Mechatronics and Automation · Vol. 9, Issue 2, 2022 · pp. 17–31` Read article
-
Reduction of Harmonics for Isolated Diesel Generation System with DSTATCOM Using Fuzzy
Abstract: This paper presents the compensation of reactive power, harmonics, and unbalanced load current of diesel generator set for an isolated system by controlling voltage source convertor (VSC) which is working as distribution static synchronous compensator (DSTATCOM). Here least mean square based adaptive linear element (ADALINE) is use to extract balanced positive sequence real fundamental frequency component of the load current for converter and used to control DSTATCOM. For fast dynamic …
Published in Journal of Automobile Engineering and Applications · Vol. 2, Issue 3, 2015 · pp. 12–22 Read article
-
A Review on Solar Multilevel Inverter for the Production of Free Energy Due to the Structure with Long-life Feature
Abstract: Multilevel inverters play a major role in medium voltage, high power and renewable applications. It is also used in certain applications where high switching frequency, and high output voltage gain are required. The switching transient period of a MOSFET should be minimal because a high dv/dt rate could result in permanent damage to the MOSFET. The harmonics present could cause many problems and so it has to be minimized. The …
Published in Journal of Nuclear Engineering & Technology · Vol. 14, Issue 1, 2024 · pp. 13–18 Read article
-
Harmony Search Algorithm For PAPR Reduction
Abstract: Normal 0 false false false EN-US X-NONE X-NONE Orthogonal frequency division multiplexing (OFDM) is just about the finest technology used not long ago within connection CPA networks. It offers a number of rewards which include excessive spectral effectiveness, improved funnel convenience of the actual given electrical power finances and the likes. Not-withstanding these kinds of rewards, OFDM owns particular negatives likewise, such as inter-block disturbance (IBI), inter-carrier disturbance (ICI) along …
Published in Recent Trends in Electronics Communication Systems · Vol. 3, Issue 1, 2016 · pp. 29–34 Read article
-
Design and Analysis of a Solar-Wind Hybrid System
Abstract: Renewable energy sources like wind and solar energies can be combined to increase the totalpower generation and thereby increase the efficiency of the system. The combination alsoprovides a means to overcome the intermittent nature of the solar and wind renewable energysources, since one source can be used for power generation when the other is not available.AC-DC converters are used to convert the alternating voltage of the wind generator to aconstant …
Published in Journal of Power Electronics and Power Systems · Vol. 10, Issue 1, 2020 · pp. 1–8 Read article
-
Simulation of Three Phase PWM Rectifier for Reduced Harmonics in Line Current using FOPID Controller
Abstract: Abstract: The proposed system is three phases PWM rectifier with current controlled loop which issued for harmonic reduction in A.C. current. The current controlled loop consists of FOPID controller which reduce peak overshoot FOPID controller has benefit in stabilizing DC voltage. The simulation confirms the effectiveness of the proposed method by giving low harmonics output and less amount of power loss in which switching time is controlled to increase energy …
Published in Journal of Instrumentation Technology & Innovations · Vol. 9, Issue 1, 2019 · pp. 29–35 Read article
-
Single-Phase Two-Stage Multi-Level Inverter Employing Low Number of Switching Devices
Abstract: In recent years, multilevel inverter (MLI) plays a significant role in low or medium voltage applications as a result of generating voltage with reduced harmonic contents. This paper proposes a new version of multi-level inverters (MLI) with reduced switching devices along with reduced harmonics content of output voltage, which results in low switching losses compared with conventional MLI topologies. In addition, the proposed inverter provides low total blocked voltage compared …
Published in Journal of Power Electronics and Power Systems · Vol. 9, Issue 2, 2019 · pp. 22–32 Read article
-
A Study of Cycloconverter Gating Sequence and Control Strategy for Various Conversion Topology
Abstract: This paper presents the topology of direct conversion of AC-AC with step down frequency operation. Due to the higher order harmonics, AC conversion always faces difficulty and complex calculation, which affects the output response. Precise controlling and harmonics reduction is much easier using frequency control strategy. In this regards cycloconverter has drawn higher attention in terms of frequency conversion. In this paper, an approach for designing of single phase and …
Published in Trends in Electrical Engineering · Vol. 6, Issue 3, 2016 · pp. 67–77 Read article
-
Harmonic Compensation in Grid Interconnected DG Units by Closed Loop Control
Abstract: This paper deals with improvement of power quality problem namely harmonic problem using distributed generation as their source of electricity. The harmonics occur in such a system because of the nature of loads connected. There are many power quality problems; out of which harmonics normally caused by nonlinear loads like variable frequency drives, fluorescent lightning, office computers etc. have adverse effects on the power quality. Also, harmonic detection and prediction …
Published in Journal of Power Electronics and Power Systems · Vol. 7, Issue 1, 2017 · pp. 9–17 Read article
-
An Extensive Review of different PWM Techniques
Abstract: In Alternating Current Power, the quantity of sinusoidal waveform is not matters.The important is quality of sine waveform than quantity so to improve the quality of waveform,the reduction in harmonic content is necessary.For this achievement, different PWM techniques is used.This paper includes four basic PWM techniques single PWM,multiple PWM ,sinusoidal PWM and Hysteresis PWM.
Published in Current Trends in Signal Processing · Vol. 11, Issue 1, 2021 · pp. 26–29 Read article
-
Investigation of FPGA based PWM Control Technique for AC Motors
Abstract: This paper proposes a Random Frequency PWM synchronized for a three phase inverter implemented with use of Field Programmable Gate Array (FPGA) and applied to a 1-hp induction motor drive system for the reduction of harmonics and improvement of fundamental peak voltage. For providing alternating output voltage with a specific magnitude and frequency to industrial applications, three-phase inverter is preferred. The gating signals to the inverter are produced by means …
Published in Journal of Power Electronics and Power Systems · Vol. 3, Issue 2, 2013 · pp. 16–22 Read article
-
Torque Ripple Minimization of High-Power Fed Induction Motor Drive Using Low Switching Frequency
Abstract: Multi-level inverter has emerged as an important topology in the area of high-power-medium voltage energycontrol applications due to its several advantages such as its good harmonic rejection capability, betteroutput voltage with reduced ripple, reduction of voltage ratings of the power semiconductor switchingdevices and also the reduced electro-magnetic interference problems, etc. This paper presents the torqueripple minimization and the performance under different operating conditions (dynamic and steady state) ofindirect vector-controlled high-power …
Published in Journal of Power Electronics and Power Systems · Vol. 1, Issue 1-2-3, 2011 · pp. 72–83 Read article
-
A Review On A Compact Dual Polarized Antenna Array
Abstract: A compact dual-polarized antenna array for low-cost millimeter-wave (mm Wave) applications is proposed in this article. Utilizing a patch antenna with two orthogonal feeds positioned horizontally and vertically, a dual linear polarization antenna can be created. Two ports—a vertical port and a horizontal port—make up the suggested design. The antenna produces horizontal polarization by stimulating the horizontal port. The antenna produces vertical polarization by stimulating vertical port. With the higher …
Published in Journal of Microwave Engineering and Technologies · Vol. 9, Issue 2, 2022 · pp. 46–50 Read article
-
Analysis and Design of Multi level Inverter
Abstract: Multilevel Inverter (MLI) has been accepted as an attractive topology for high voltage DC-AC conversion. This paper focuses on a reference modulation technique for a hybrid multilevel inverter technique based on reduced Total harmonic distortion and total number of used Power electronics Switches the results of reduction of total cost ,installation area and reduced circuit complexity due to gate driver circuit. Pulse width modulation technique to generate firing pluses. Over …
Published in Journal of Multimedia Technology & Recent Advancements · Vol. 3, Issue 2, 2016 · pp. 26–33 Read article
-
Reliability-Aware Multimodal Sentiment Analysis Using Speech, Visual and Textual Signals: A CMU-MOSEI Benchmark Re-analysis
Abstract: Multimodal sentiment analysis integrates linguistic, acoustic, and visual cues, but reported gains often assume that every modality is present and equally reliable. This study develops a reliability-aware multimodal sentiment-analysis framework and performs a quantitative re-analysis of verified CMU- MOSEI benchmark results to determine how modality availability changes predictive performance. The conceptual architecture combines text, acoustic, and visual encoders with quality-conditioned gated fusion. For the quantitative component, complete- and missing-modality results …
Published in Journal of Electronic Design Technology · Vol. 17, Issue 3, 2026 Read article