Search
11 articles for “unbalanced operation”
-
Operating Limits of Three-phase Self-excited Induction Generator under Unbalanced Operations
Abstract: This paper presents a new GA based model to analyze the steady state performance of the self-excited induction generator (SEIG) under unbalanced load and excitation. The proposed model is based upon the load decoupled approach using symmetrical component theory. The simulated results as obtained using proposed model are compared with experimental results on a test machine. Close agreement with the experimental results proves the effectiveness of GA based model and …
Published in Journal of Alternate Energy Sources & Technologies · Vol. 4, Issue 3, 2013 · pp. 13–29 Read article
-
Design Parameters of Three-phase Self-excited Induction Generator for Desired Performance under Unbalanced Operations
Abstract: Self-excited induction generators are widely used for power generation using wind energy in remote and windy locations. However, the load in such generating units may become unbalance and sometimes the excitation capacitance may be unbalance due to aging effect or manufacturing tolerance. All this reflect a strong need for the analysis of such machines under unbalanced operations. In this paper, proposed model as presented has been framed in order to …
Published in Journal of Power Electronics and Power Systems · Vol. 4, Issue 1, 2014 · pp. 1–12 Read article
-
Performance Estimation of Self-Excited Induction Generator under Different Power Factor Loading
Abstract: The paper presents a model, which has been analyzed using genetic algorithm, in order to estimate the steady state performance of three-phase self-excited induction generator under unbalanced operation. The technique as proposed has been implemented on a 15 KW rating machine to see the effect of variation in load power factor of one phase and two phases simultaneously on phase voltages, phase currents, degree of unbalance, power output, power losses …
Published in Journal of Alternate Energy Sources & Technologies · Vol. 7, Issue 2, 2016 · pp. 12–16 Read article
-
Refractive-Type Fresnel Lens Concentrated Solar Water Heater-cum-Distillation Unit
Abstract: This paper presents a new GA based model to analyze the steady state performance of the self-excited induction generator (SEIG) under unbalanced load and excitation. The proposed model is based upon the load decoupled approach using symmetrical component theory. The simulated results as obtained using proposed model are compared with experimental results on a test machine. Close agreement with the experimental results proves the effectiveness of GA based model and …
Published in Journal of Alternate Energy Sources & Technologies · Vol. 4, Issue 3, 2013 · pp. 30–38 Read article
-
Mathematical Modelling of an Unbalanced Rotor Subjected to Transverse Vibrations
Abstract: The static and dynamic balancing of a rotor plays a very important role in deciding the life-span of any turbo-machinery which is running at a very high speed. The major problems which face during the running of turbo machineries are unbalancing of the rotor. Rotor unbalance may be due to wrong selection of the manufacturing process, method of manufacturing, wear and tear of rotating component, thermal deformations, deposition of material …
Published in Trends in Machine design · Vol. 7, Issue 1, 2020 · pp. 9–16 Read article
-
Operative Protection Fortitude for Agip 1x15 MVA, 33/11KV Injection Substation
Abstract: The Electrical Power System generally consist of the Generation, transmission and distribution and this system require an adequate protection in it layers of operation to help protect electrical loads and equipment from damaging as to ensure healthy and quality power supply in the power system. The fault associated with this substation are short circuits, overloads, phase unbalance/imbalance, poor usage of protection which in turns causes regular trips/damage on equipment at …
Published in Journal of Electronic Design Technology · Vol. 13, Issue 3, 2022 · pp. 1–8 Read article
-
Generation of Wind Power using Doubly Fed Induction Generator
Abstract: Due to independent controlling mechanism for the active and reactive power, doubly fed induction generator (DFIG) is still culled by the wind turbine companies. The control strategies are continuously advancing to manage the grid codes (i.e. reactive power compensation, low voltage ride-through operation). This paper focuses on the control strategies using combined reactive power compensation for power converters to maintain the optimized lifetime distribution under normal grid conditions. An advanced …
Published in Research & Reviews : Journal of Physics · Vol. 7, Issue 3, 2018 · pp. 73–78 Read article
-
Artificial Neural Network Based SVC Switching At Distribution System for Minimal Injected Harmonics
Abstract: Electrical distribution system grieves from various problems like reactive power burden, unbalanced loading, voltage regulation and harmonic distortion. However DSTATCOMS are ideal solutions for such systems, they are not popular because of the cost and complexity of control involved. Phase wise balanced reactive power compensations are essential for fast changing loads needing dynamic power factor correcting devices leading to terminal voltage stabilization. Static Var Compensators (SVCs) remain ideal choice for …
Published in Trends in Electrical Engineering · Vol. 9, Issue 1, 2019 · pp. 41–47 Read article
-
Ethical Consideration in the Use of Artificial Intelligence in Medicine and Healthcare
Abstract: Artificial Intelligence (AI) in medicine and healthcare offers tremendous potential for improving patient care, increasing the precision of diagnoses, and increasing operational efficiency. To ensure responsible application, however, the swift uptake of AI technologies also brings up important ethical concerns that need to be addressed. This article explores various ethical challenges in healthcare AI, including concerns about algorithmic bias, data privacy, informed consent, and accountability. Patients must be aware of …
Published in International Journal of Biomedical Innovations and Engineering · Vol. 3, Issue 1, 2025 · pp. 23–28 Read article
-
Reduction of Harmonics for Isolated Diesel Generation System with DSTATCOM Using Fuzzy
Abstract: This paper presents the compensation of reactive power, harmonics, and unbalanced load current of diesel generator set for an isolated system by controlling voltage source convertor (VSC) which is working as distribution static synchronous compensator (DSTATCOM). Here least mean square based adaptive linear element (ADALINE) is use to extract balanced positive sequence real fundamental frequency component of the load current for converter and used to control DSTATCOM. For fast dynamic …
Published in Journal of Automobile Engineering and Applications · Vol. 2, Issue 3, 2015 · pp. 12–22 Read article
-
Integration of Polymer and Composite Materials in Modern Culinary Practices: An Assessment of Innovation Gaps in Uttar Pradesh's Hospitality Sector
Abstract: The hospitality industry is experiencing a swift change owing to the material innovation, sustainability demands, and changing consumer expectations. Polymer and composite materials have become key facilitators of contemporary culinary life and as such, they possess the following benefits; lightweight design, durability, thermal resistance, hygiene, and design flexibility in kitchenware, food packages, service ware, and intelligent culinary devices. Nonetheless, the incorporation of high-quality polymer and composite materials into the local …
Published in Journal of Polymer & Composites · Vol. 14, Issue 2, 2026 · pp. 431–446 Read article