Short Report on Capillary Flow in Microfluidics
Abstract: In this experimental work, a single SU-8 based glass microfluidic device is fabricated by masklesslithography and indirect bonding technique. The sealing between glass lid and SU-8 basedmicrochannel structure is performed by indirect bonding technique during the hard baking. Dyed wateris prepared as working liquid to record the surface-driven capillary flow in microfluidics using a CMOScamera catching 25 frames per second with a corresponding time-scale resolution of 0.04 second. Thiswork may …
Published in Journal of Materials & Metallurgical Engineering · Vol. 11, Issue 1, 2021 · pp. 34–37 Read article
-
Experimental Demonstration on the Leakage-Free Surface-Driven Capillary Flow of Red Dye
Abstract: In this work, two individual SU-8 based glass microfluidic devices are fabricated by the maskless lithography and indirect bonding technique. Commercially available red-colored food dye is used as the working liquid. Microfluidic leakage is observed between the glass lid and SU-8 based microchannel substrate due to the improper indirect bonding technique. Leakage-free surface-driven capillary flow is observed due to the proper indirect bonding technique. CMOS camera is used to capture …
Published in Journal of Catalyst & Catalysis · Vol. 5, Issue 3, 2018 · pp. 8–11 Read article
-
Short Experimental Report on Lithographic Technique in Microfluidics
Abstract: In this experimental work, a single SU-8 based glass microfluidic device is fabricated by the maskless lithography and indirect bonding technique. The sealing by indirect bonding technique is perform during the hard baking in maskless lithography. Dyed ethylene glycol is prepared as the working liquid. A CMOS camera catching 25 frames per second with a corresponding time-scale resolution of 0.04 second is used to record the surface-driven microfluidic flow of …
Published in Journal of Microwave Engineering and Technologies · Vol. 8, Issue 3, 2021 · pp. 1–5 Read article
-
Optical Recording of Flow Phenomena in Photoresist based Microfluidic Devices
Abstract: AbstractIn this experimental work, a set of three individual SU-8 based glass microfluidic devices are fabricated by maskless lithography and indirect bonding technique without having any microfluidic leakage. Dyed ethanol (10% ethanol, 90% red dye) is prepared and used as dyed working liquid. The microfluidic leakage is observed in other set of two leaky microfluidic devices due to improper indirect bonding technique. The effect of surface-to-volume ratio on surface-driven capillary …
Published in Trends in Opto-electro & Optical Communication · Vol. 10, Issue 1, 2020 · pp. 36–42 Read article
-
Optimisation of the Experimental Methods for the Fabrication of Polymer Microstructures and Polymer Microfluidic Devices for Bioengineering Applications
Abstract: In this research paper, total 2278 individual polymer microstructures have been fabricated, measured and analyzed. Also, in this research paper, total 216 individual polymer microfluidic devices have been fabricated by the maskless lithography, hot embossing lithography, direct bonding technique, and indirect bonding technique, to record and analyze the surface-driven (passive) capillary flow individually in each microfluidic device. Total three individual polymers as SU8, polymethylmethacrylate (PMMA), and polyimide have been used …
Published in Journal of Polymer & Composites · Vol. 4, Issue 3, 2016 · pp. 8–26 Read article
-
Short Review on the Flow and Filtration of Polystyrene Microparticles in Micron-Scale Fluid Mechanics towards the Applications related to fluidic Microelectromechanical Systems
Abstract: Maskless lithography, hot embossing lithography and direct bonding technique are useful to fabricate the polymethylmethacrylate (PMMA) microfluidic devices. Also, maskless lithography and indirect bonding technique are useful to fabricate the SU-8 based glass microfluidic devices. In this work, a short review on microfluidic flow and microfluidic filtration of microparticles is provided by author related to the micron-scale fluid mechanics. This review may be useful to perform the blood filtration in …
Published in Journal of Microelectronics and Solid State Devices Read article
-
Short Review on Maskless Lithography in Microfluidics
Abstract: Maskless lithography is a part of the overall microfabrication technique to fabricate the polymer based microfluidic devices. Polymer based microfluidic devices are fabricated using the polymethylmethacrylate (PMMA) and SU-8 as two commonly used polymers. PMMA microfluidic devices are fabricated by the maskless lithography, hot embossing lithography and direct bonding technique. SU-8 based glass microfluidic devices are fabricated by the maskless lithography, and indirect bonding technique. Therefore, maskless lithography is proved …
Published in Emerging Trends in Chemical Engineering · Vol. 6, Issue 1, 2019 · pp. 32–34 Read article
-
Flow and Filtration of Polystyrene Microparticles in Micron-Scale Fluid Mechanics towards the Applications related to fluidic Microelectromechanical Systems
Abstract: Maskless lithography, hot embossing lithography and direct bonding technique are useful to fabricate the polymethylmethacrylate (PMMA) microfluidic devices. Also, maskless lithography and indirect bonding technique are useful to fabricate the SU-8 based glass microfluidic devices. In this work, a short review on microfluidic flow and microfluidic filtration of microparticles is provided by author related to the micron-scale fluid mechanics. This review may be useful to perform the blood filtration in …
Published in Journal of Microelectronics and Solid State Devices · Vol. 8, Issue 3, 2021 · pp. 36–41 Read article
-
Microfluidic Flow of the Dyed Aqueous Isopropyl Alcohol in a single SU-8 based Glass Microfluidic Device Fabricated inside the Cleanroom Laboratory
Abstract: A single SU-8 based glass microfluidic device is fabricated by maskless lithography and indirect bonding technique, using author’s own hands-on completely inside the cleanroom laboratory. Dyed aqueous isopropyl alcohol (90% dyed water, 10% isopropyl alcohol) is the prepared working liquid in this work. The surface-driven microfluidic flow of working liquid is recorded by a CMOS camera catching 25 frames per second with a corresponding time-scale resolution of 0.04 second. The …
Published in Journal of Catalyst & Catalysis · Vol. 6, Issue 1, 2019 · pp. 10–13 Read article
-
Experimental Demonstration on Microfluidic Capillary Flow of Red Dye in Photoresist based Glass Microfluidic Devices
Abstract: In this experimental work, a set of three individual SU-8 based glass microfluidic devices are fabricated by maskless lithography and indirect bonding technique in leakage-free conditions. Commercially available red coloured food dye is used as the selected working liquid. The microfluidic leakage in other set of two leaky microfluidic devices is experimentally demonstrated. Microfluidic devices should be fabricated at leakage-free conditions to achieve exact fluid flow characteristics. The effect of …
Published in Journal of Thin Films, Coating Science Technology & Application · Vol. 7, Issue 1, 2020 · pp. 1–7 Read article
-
Surface-Driven Microfluidic Flow in Fluid Mechanics
Abstract: In this short report, a brief review on surface-driven microfluidic flow is provided. Also, the maskless lithography and indirect bonding technique are used to fabricate a single SU-8 based glass microfluidic device. Dyed ethylene glycol is prepared as working liquid to test the fabricated device. The surface-driven microfluidic flow of dyed ethylene glycol is recorded by a CMOS camera catching 25 frames per second with a corresponding time-scale resolution of …
Published in Recent Trends in Fluid Mechanics · Vol. 8, Issue 3, 2021 · pp. 1–5 Read article
-
Short Report to Describe the Surface-driven Microfluidic Flow in Fluid Mechanics
Abstract: In this short report, a brief review on surface-driven microfluidic flow is provided. Also, the maskless lithography and indirect bonding technique are used to fabricate a single SU-8 based glass microfluidic device. Dyed ethylene glycol is prepared as working liquid to test the fabricated device. The surface-driven microfluidic flow of dyed ethylene glycol is recorded by a CMOS camera catching 25 frames per second with a corresponding time-scale resolution of …
Published in Recent Trends in Fluid Mechanics Read article
-
Passive Capillary Flow of Aqueous Working Liquids in the SU-8 based Microchannel Bends
Abstract: In this work, total 4 individual SU-8 based microchannel bends are fabricated by maskless lithography and indirect bonding technique. The leakage-free surface-driven capillary flow of aqueous ethanol is recorded by a CMOS camera. Also, the leakage-free surface-driven capillary flow of aqueous isopropyl alcohol (IPA) is recorded by the CMOS camera. This work will be useful in bioengineering applications.
Published in Emerging Trends in Chemical Engineering · Vol. 5, Issue 1, 2018 · pp. 20–22 Read article
-
Surface-Driven Capillary Flow of the Dyed Aqueous Ethanol in a single SU-8 based Glass Microfluidic Device integrated with the Arrays of Square Polyimide Micropillars
Abstract: In this work, a single SU-8 based glass microfluidic device is fabricated by the maskless lithography and indirect bonding technique. A particular polyimide layer at the selected portions and the arrays of square polyimide micropillars at the other portions are integrated on the microchannel bottom wall by the maskless lithography. Dyed aqueous ethanol (70% dyed water, 30% ethanol) is prepared as the working liquid in this work. A CMOS camera …
Published in Journal of Thin Films, Coating Science Technology & Application · Vol. 6, Issue 1, 2019 · pp. 33–37 Read article
-
Fabrication of the SU-8 based Glass Microfluidic Devices to Record the Surface-Driven Capillary Flow of Water
Abstract: Total 12 individual leakage-free SU-8 based glass microfluidic devices are fabricated by the maskless lithography and indirect bonding technique. The surface-driven capillary flow of dyed water is successfully recorded inside these microfluidic devices. Total 12 individual audio video interleave files as ‘FileName.avi’ are recorded and analyzed in this research paper. This study may be useful for different microfluidic applications.
Published in Journal of Thin Films, Coating Science Technology & Application · Vol. 3, Issue 3, 2016 · pp. 9–12 Read article
-
Report on Microfluidic Flow of Dyed Working Liquids inside the Polymeric Devices
Abstract: In this experimental work, a single SU-8 based glass microfluidic device is engineered by the maskless lithography and indirect bonding technique. Also, total nine individual polymethylmethacrylate (PMMA) based microfluidic devices are fabricated by maskless lithography, hot embossing lithography, and direct bonding technique. Dyed ethylene glycol, dyed ethanol, and dyed aqueous isopropyl alcohol (50% water, 50% IPA) are prepared and used as working liquids to record each surface-driven microfluidic flow. The …
Published in Journal of Thin Films, Coating Science Technology & Application · Vol. 8, Issue 1, 2021 · pp. 22–29 Read article
-
Recording of Surface-Driven Laminar Flow in Dual Sudden Expansion Microchannel of a Single SU-8 based Glass Microfluidic Device
Abstract: In this work, the SU-8 based glass microfluidic device is fabricated by maskless lithography and indirect bonding technique. A dual sudden expansion microchannel is designed and fabricated inside this fabricated glass microfluidic device. Dyed water is prepared as working liquid by mixing commercially available food dye with distilled water. The surface-driven laminar flow of dyed water inside the fabricated microchannel is recorded by a CMOS camera. This experimental work is …
Published in Recent Trends in Fluid Mechanics · Vol. 7, Issue 1, 2020 · pp. 24–27 Read article
-
Passive Capillary Flow of Red Dye in the SU-8 based Glass Microfluidic Devices
Abstract: In this work, total three individual SU-8 based glass microfluidic devices are fabricated by the maskless lithography and indirect bonding technique. Commercially available red coloured food dye is used as working liquid. Individual surface-driven capillary flows of red dye are recorded by the CMOS camera. This work will be useful in bioengineering applications.
Published in Trends in Mechanical Engineering & Technology · Vol. 8, Issue 3, 2018 · pp. 59–61 Read article
-
Real-Life Demonstration on the Surface-Driven Capillary Flow in Microfluidic Devices
Abstract: AbstractIn this research paper, glass and PMMA are chosen as materials to fabricate the microfluidic devices due to the optical transparency of these materials. The microfluidic devices are fabricated by the maskless lithography (non-contact lithography), hot embossing lithography (contact lithography), indirect bonding technique, and direct bonding technique. The surface-driven capillary flow is recorded corresponding to each microfluidic device by a CMOS camera. The colour-images are compared with the gray-scale-images for …
Published in Trends in Opto-electro & Optical Communication · Vol. 6, Issue 2, 2016 · pp. 8–17 Read article