SU-8
22 articles · search the full text for this term
-
Short Report to Describe the Surface-driven Microfluidic Flow in Fluid Mechanics
Abstract: In this short report, a brief review on surface-driven microfluidic flow is provided. Also, the maskless lithography and indirect bonding technique are used to fabricate a single SU-8 based glass microfluidic device. Dyed ethylene glycol is prepared as working liquid to test the fabricated device. The surface-driven microfluidic flow of dyed ethylene glycol is recorded by a CMOS camera catching 25 frames per second with a corresponding time-scale resolution of …
Published in Recent Trends in Fluid Mechanics · Vol. 9, Issue 4, 2022 · pp. 1–5 Read article
-
Surface-Driven Microfluidic Flow in Fluid Mechanics
Abstract: In this short report, a brief review on surface-driven microfluidic flow is provided. Also, the maskless lithography and indirect bonding technique are used to fabricate a single SU-8 based glass microfluidic device. Dyed ethylene glycol is prepared as working liquid to test the fabricated device. The surface-driven microfluidic flow of dyed ethylene glycol is recorded by a CMOS camera catching 25 frames per second with a corresponding time-scale resolution of …
Published in Recent Trends in Fluid Mechanics · Vol. 8, Issue 3, 2021 · pp. 1–5 Read article
-
Short Experimental Report on Lithographic Technique in Microfluidics
Abstract: In this experimental work, a single SU-8 based glass microfluidic device is fabricated by the maskless lithography and indirect bonding technique. The sealing by indirect bonding technique is perform during the hard baking in maskless lithography. Dyed ethylene glycol is prepared as the working liquid. A CMOS camera catching 25 frames per second with a corresponding time-scale resolution of 0.04 second is used to record the surface-driven microfluidic flow of …
Published in Journal of Microwave Engineering and Technologies · Vol. 8, Issue 3, 2021 · pp. 1–5 Read article
-
Microfluidic Features in Fluid Mechanics for Bioengineering Applications
Abstract: In this work, a single SU-8 based glass microfluidic device is fabricated by the mask less lithography and indirect bonding technique. The sealing is performed by author during the hard baking in maskless lithography. Dyed water is prepared as working liquid in this work. A CMOS camera catching 25 frames per second with a corresponding time-scale resolution of 0.04 second is used by the author to record the surface-driven capillary …
Published in Research and Reviews : A Journal of Biotechnology · Vol. 11, Issue 3, 2021 · pp. 1–4 Read article
-
Polymer Processing in Microfluidics towards the Fabrication of Nanofluidic Systems in Nanotechnology
Abstract: This experimental work reports two individual SU-8 based glass microfluidic devices to be fabricated by maskless lithography along with indirect bonding technique using the steps of SU-8 processing. Dyed water is the selected and prepared working liquid for this work. The CMOS camera is used to record the passive microfluidic flow of dyed water in fabricated devices. In future, this report may be suitable to investigate the nanofluidic flow phenomena …
Published in Journal of Nanoscience, NanoEngineering & Applications · Vol. 11, Issue 2, 2021 · pp. 27–31 Read article
-
Short Review on Fluid Mechanics with the Domain of Nanotechnology for Applications in Nuclear-Reactors
Abstract: In this work, a brief review on microfluidic flow is provided. Also, the brief ideas on very large scale integration (VLSI) circuits are provided. A single polymethylmethacrylate (PMMA) based gradual expansion microchannel is fabricated by the maskless lithography, hot embossing lithography and direct bonding technique. Surface-driven microfluidic flow of dyed water is recorded in the fabricated device using a CMOS camera catching 25 frames per second with a corresponding time-scale …
Published in Nano Trends – A Journal of Nano Technology & Its Applications · Vol. 23, Issue 2, 2021 · pp. 45–50 Read article
-
Chemical Processing of SU-8 Photoresist to Record the Surface-Driven Microfluidic Flow of Dyed Working Liquid in the Regime of Fluid Mechanics
Abstract: Chemical processing of negative photoresist SU-8 is performed to fabricate a set of three individualSU-8 based glass microfluidic devices inside the cleanroom laboratory. The major steps of SU-8processing are spin coating using a spin coater, soft baking, ultra-violet (UV) exposure, post exposurebaking, development by SU-8 developer, and hard baking. The indirect bonding for leakage-freesealing is used during hard baking to fabricate the microfluidic devices. Author has prepared thedyed water to …
Published in Emerging Trends in Chemical Engineering · Vol. 8, Issue 1, 2021 · pp. 53–57 Read article
-
Short Review on Microfluidic Lab-on-a-Chip Systems for Future Applications in Space Technology
Abstract: The brief description on laboratory-on-a-chip systems for microfluidic applications is provided in this short review. The fabrication of polymethylmethacrylate (PMMA) based microfluidic device is briefly described by providing recorded snap-shot images of surface-driven capillary flow in PMMA microchannel bend. Microfluidic lab-on-a-chip systems are already useful in bioengineering and materials-science. A brief attempt has been made to establish the probable applications of microfluidic lab-on-a-chip systems in space technology. Concept theory is …
Published in Journal of Nanoscience, NanoEngineering & Applications · Vol. 10, Issue 1, 2020 · pp. 26–30 Read article
-
Experimental Demonstration on Microfluidic Capillary Flow of Red Dye in Photoresist based Glass Microfluidic Devices
Abstract: In this experimental work, a set of three individual SU-8 based glass microfluidic devices are fabricated by maskless lithography and indirect bonding technique in leakage-free conditions. Commercially available red coloured food dye is used as the selected working liquid. The microfluidic leakage in other set of two leaky microfluidic devices is experimentally demonstrated. Microfluidic devices should be fabricated at leakage-free conditions to achieve exact fluid flow characteristics. The effect of …
Published in Journal of Thin Films, Coating Science Technology & Application · Vol. 7, Issue 1, 2020 · pp. 1–7 Read article
-
Microfluidic Flow of the Dyed Aqueous Isopropyl Alcohol in a single SU-8 based Glass Microfluidic Device Fabricated inside the Cleanroom Laboratory
Abstract: A single SU-8 based glass microfluidic device is fabricated by maskless lithography and indirect bonding technique, using author’s own hands-on completely inside the cleanroom laboratory. Dyed aqueous isopropyl alcohol (90% dyed water, 10% isopropyl alcohol) is the prepared working liquid in this work. The surface-driven microfluidic flow of working liquid is recorded by a CMOS camera catching 25 frames per second with a corresponding time-scale resolution of 0.04 second. The …
Published in Journal of Catalyst & Catalysis · Vol. 6, Issue 1, 2019 · pp. 10–13 Read article
-
Short Review on Maskless Lithography in Microfluidics
Abstract: Maskless lithography is a part of the overall microfabrication technique to fabricate the polymer based microfluidic devices. Polymer based microfluidic devices are fabricated using the polymethylmethacrylate (PMMA) and SU-8 as two commonly used polymers. PMMA microfluidic devices are fabricated by the maskless lithography, hot embossing lithography and direct bonding technique. SU-8 based glass microfluidic devices are fabricated by the maskless lithography, and indirect bonding technique. Therefore, maskless lithography is proved …
Published in Emerging Trends in Chemical Engineering · Vol. 6, Issue 1, 2019 · pp. 32–34 Read article
-
Surface-Driven Capillary Flow of the Dyed Aqueous Ethanol in a single SU-8 based Glass Microfluidic Device integrated with the Arrays of Square Polyimide Micropillars
Abstract: In this work, a single SU-8 based glass microfluidic device is fabricated by the maskless lithography and indirect bonding technique. A particular polyimide layer at the selected portions and the arrays of square polyimide micropillars at the other portions are integrated on the microchannel bottom wall by the maskless lithography. Dyed aqueous ethanol (70% dyed water, 30% ethanol) is prepared as the working liquid in this work. A CMOS camera …
Published in Journal of Thin Films, Coating Science Technology & Application · Vol. 6, Issue 1, 2019 · pp. 33–37 Read article
-
Fabrication of the SU-8 based Glass Microfluidic Devices to Record the Surface-Driven Capillary Flow of Water
Abstract: Total 12 individual leakage-free SU-8 based glass microfluidic devices are fabricated by the maskless lithography and indirect bonding technique. The surface-driven capillary flow of dyed water is successfully recorded inside these microfluidic devices. Total 12 individual audio video interleave files as ‘FileName.avi’ are recorded and analyzed in this research paper. This study may be useful for different microfluidic applications.
Published in Journal of Thin Films, Coating Science Technology & Application · Vol. 3, Issue 3, 2016 · pp. 9–12 Read article
-
Experimental Demonstration on the Leakage-Free Surface-Driven Capillary Flow of Red Dye
Abstract: In this work, two individual SU-8 based glass microfluidic devices are fabricated by the maskless lithography and indirect bonding technique. Commercially available red-colored food dye is used as the working liquid. Microfluidic leakage is observed between the glass lid and SU-8 based microchannel substrate due to the improper indirect bonding technique. Leakage-free surface-driven capillary flow is observed due to the proper indirect bonding technique. CMOS camera is used to capture …
Published in Journal of Catalyst & Catalysis · Vol. 5, Issue 3, 2018 · pp. 8–11 Read article
-
Passive Capillary Flow of Red Dye in the SU-8 based Glass Microfluidic Devices
Abstract: In this work, total three individual SU-8 based glass microfluidic devices are fabricated by the maskless lithography and indirect bonding technique. Commercially available red coloured food dye is used as working liquid. Individual surface-driven capillary flows of red dye are recorded by the CMOS camera. This work will be useful in bioengineering applications.
Published in Trends in Mechanical Engineering & Technology · Vol. 8, Issue 3, 2018 · pp. 59–61 Read article
-
Passive Capillary Flow of Aqueous Working Liquids in the SU-8 based Microchannel Bends
Abstract: In this work, total 4 individual SU-8 based microchannel bends are fabricated by maskless lithography and indirect bonding technique. The leakage-free surface-driven capillary flow of aqueous ethanol is recorded by a CMOS camera. Also, the leakage-free surface-driven capillary flow of aqueous isopropyl alcohol (IPA) is recorded by the CMOS camera. This work will be useful in bioengineering applications.
Published in Emerging Trends in Chemical Engineering · Vol. 5, Issue 1, 2018 · pp. 20–22 Read article
-
Aesthetic Values of the Surface-Driven Capillary Flow in SU-8 based Glass Microfluidic Devices
Abstract: In this research paper, author has fabricated total 422 individual SU-8 based glass microfluidic devices by the maskless lithography, clamping, and diamond-like carbon (DLC) coating using his own hands-on completely. Also, total 422 individual Audio-Video- Interleave-Files as ‘FileName.avi’ related to these microfluidic devices have been recorded and analysed by the author completely. The influence of effective viscosity on the surface- driven capillary flow of aqueous microparticle suspensions has been experimentally …
Published in Journal of Nuclear Engineering & Technology · Vol. 6, Issue 3, 2016 Read article
-
Microfluidic Flow of Dyed Water in the SU-8 based Glass Devices
Abstract: Two individual SU-8 based glass microfluidic devices are fabricated by the maskless lithography and indirect bonding technique. Dyed water is used as working liquid to record the surface-driven capillary flow in each microfluidic device. In the indirect bonding technique, polymethylmethacrylate (PMMA) dissolved in EC solvent is used as the adhesive material to fabricate the leakage-free microfluidic device. CMOS camera is used as the recording tool in this work. This work …
Published in Research & Reviews : Journal of Physics · Vol. 6, Issue 3, 2017 · pp. 14–17 Read article
-
Passive Capillary Flow of Aqueous Microparticle Suspensions in the Straight Microchannels fabricated by the Negative Photoresist SU-8
Abstract: A group of microfluidic devices are fabricated by the SU-8 negative photoresist using the standard SU-8 processing techniques. The influences of effective viscosity, channel aspect ratio and surface wettability on the surface-driven capillary flow of aqueous microparticle suspensions are individually studied in straight microchannels. Nano-films of diamond like carbon (DLC) are used to vary the surface wettability on SU-8 based microchannel structures. The number densities of suspended polystyrene microparticles in …
Published in Journal of Modern Chemistry & Chemical Technology · Vol. 8, Issue 3, 2017 · pp. 37–39 Read article
-
Experimental Studies on the Capillary Flow Phenomena in Polyimide Based Glass Microfluidic Devices
Abstract: The polyimide based glass microfluidic devices are fabricated using the maskless lithography. Water is the only working liquid in this work. The effects of micropillar side length, microfluidic friction and surface area to volume ratio on the surface-driven capillary flow of water are studied experimentally. The surface-driven capillary flow of water is slower due to higher microfluidic friction. This work will be useful to control the water inside the microfluidic …
Published in Emerging Trends in Chemical Engineering · Vol. 4, Issue 3, 2017 · pp. 22–26 Read article