Search
7 articles for “Polyimide”
-
Thermo-Mechanical and Electrical Properties of Multi-Walled Carbon Nanotube-Enhanced Polyimide Composites for Aerospace Thermal Protection Systems
Abstract: Advanced aerospace thermal protection systems (TPS) require multifunctional materials that simultaneously provide high thermal stability, mechanical strength, and reliable electrical performance. Polyimide (PI) is widely used in aerospace structures due to its lightweight design and exceptional thermal durability, yet its low thermal conductivity and insulating behavior limit its effectiveness in heat dissipation and electromagnetic interference (EMI) shielding applications. This study addresses these limitations by developing multi-walled carbon nanotube (MWCNT)-reinforced polyimide …
Published in Journal of Polymer & Composites · Vol. 13, Issue 6, 2025 · pp. 966–982 Read article
-
Surface-Driven Capillary Flow of the Dyed Aqueous Ethanol in a single SU-8 based Glass Microfluidic Device integrated with the Arrays of Square Polyimide Micropillars
Abstract: In this work, a single SU-8 based glass microfluidic device is fabricated by the maskless lithography and indirect bonding technique. A particular polyimide layer at the selected portions and the arrays of square polyimide micropillars at the other portions are integrated on the microchannel bottom wall by the maskless lithography. Dyed aqueous ethanol (70% dyed water, 30% ethanol) is prepared as the working liquid in this work. A CMOS camera …
Published in Journal of Thin Films, Coating Science Technology & Application · Vol. 6, Issue 1, 2019 · pp. 33–37 Read article
-
Experimental Studies on the Capillary Flow Phenomena in Polyimide Based Glass Microfluidic Devices
Abstract: The polyimide based glass microfluidic devices are fabricated using the maskless lithography. Water is the only working liquid in this work. The effects of micropillar side length, microfluidic friction and surface area to volume ratio on the surface-driven capillary flow of water are studied experimentally. The surface-driven capillary flow of water is slower due to higher microfluidic friction. This work will be useful to control the water inside the microfluidic …
Published in Emerging Trends in Chemical Engineering · Vol. 4, Issue 3, 2017 · pp. 22–26 Read article
-
Thermal Stability and Impact Performance of Basalt–Carbon Hybrid Laminates in Polyimide–Phenolic Matrices
Abstract: The impact resistance and thermal stability of the advanced polymer composites are properties that are necessary for the components that are subjected to dynamic conditions, which show the overall reliability and service performance of the laminates applied in automotive structures, protective casings, etc. These properties prevent premature softening or breakdown during long-term exposure to heat. Impact resistance and thermal stability of composite laminates are studied based on fiber orientation and …
Published in Journal of Polymer & Composites · Vol. 14, Issue 1, 2026 · pp. 247–260 Read article
-
Comparison Analysis of Transformer Boosting and Induced Degeneration Topology Design of LNA for Millimeter Wave Frequency Range Using Polymeric Substrates
Abstract: In this study, a comparison between transformer boosting and source degeneration LNA topologies is conducted using two polymeric substrates—Polyimide (PI) and Liquid Crystal Polymer (LCP)—for millimeter-wave (mmWave) applications. With growing interest in flexible and high-frequency electronics, polymeric materials offer unique advantages such as low dielectric constants, mechanical flexibility, and thermal stability. The analysis explores gain, return loss, and noise figure performance while evaluating the influence of dielectric properties on the …
Published in International Journal of Electrical and Communication Engineering Technology · Vol. 3, Issue 2, 2025 · pp. 1–24 Read article
-
Optimisation of the Experimental Methods for the Fabrication of Polymer Microstructures and Polymer Microfluidic Devices for Bioengineering Applications
Abstract: In this research paper, total 2278 individual polymer microstructures have been fabricated, measured and analyzed. Also, in this research paper, total 216 individual polymer microfluidic devices have been fabricated by the maskless lithography, hot embossing lithography, direct bonding technique, and indirect bonding technique, to record and analyze the surface-driven (passive) capillary flow individually in each microfluidic device. Total three individual polymers as SU8, polymethylmethacrylate (PMMA), and polyimide have been used …
Published in Journal of Polymer & Composites · Vol. 4, Issue 3, 2016 · pp. 8–26 Read article
-
Effect of Surface Free Energy on the Surface-Driven Capillary Flow in SU-8 based Glass Microfluidic Devices
Abstract: Surface-driven capillary flow of dyed water is recorded in the SU8 based glass microfluidic devices fabricated by the standard cleanroom processes. The effect of surface wettability on the surface-driven capillary flow is studied in the individual SU8 based microfluidic devices of glass bottom wall and polyimide bottom wall. The surface-driven capillary flow is faster on the glass bottom wall surface due to the higher polar component of solid surface free …
Published in Journal of Polymer & Composites · Vol. 4, Issue 3, 2016 · pp. 1–7 Read article