Search
26 articles for “retrofit analysis”
-
Seismic Response for RC Frames on Sloping Ground using Pushover Analysis
Abstract: Open story structures are to be mainly susceptible to collapse and severe damage under earthquake excitation in hill areas. Nowadays many buildings constructed have soft ground story for various purposes, for example, multipurpose hall, parking etc. The examination has been led to get the reaction of RC open story building exposed to seismic tremor loads. In present work, twelve storied structure on inclined ground (150 with horizontal) are considered. The …
Published in Journal of Structural Engineering and Management · Vol. 7, Issue 2, 2020 · pp. 36–46 Read article
-
Limestone Calcined Clay Cement (LC3) as a Sustainable Cementitious Composite for Retrofitting Concrete Structures: A Systematic Review
Abstract: This systematic review evaluates the effectiveness of Limestone Calcined Clay Cement (LC3) as a sustainable material for repairing and retrofitting damaged concrete structures. LC3 is highlighted as a low-carbon alternative to Ordinary Portland Cement (OPC), offering improved strength, bonding, and long-term durability. The review compiles and analyzes data from peer-reviewed experimental studies focusing on LC3’s mechanical performance, interface bonding, and durability parameters. Results consistently show higher bond strength, reduced shrinkage, …
Published in Journal of Polymer & Composites · Vol. 13, Issue 6, 2025 · pp. 163–174 Read article
-
Comparative Seismic Analysis of Composite Building Frames Considering Wind Pressure per I.S. 875-III: An ETABS-Based Review
Abstract: The seismic analysis of composite building frames, while factoring in wind pressure in accordance with the I.S. 875-III standards, stands as a pivotal imperative. It serves as the linchpin in guaranteeing not only the structural robustness but also the optimal performance of these edifices, ensuring they can withstand the formidable forces of nature with unwavering resilience.This study provides an in-depth and thorough analysis of past research endeavors that have delved …
Published in Journal of Construction Engineering, Technology & Management · Vol. 13, Issue 3, 2023 · pp. 1–8 Read article
-
IS-Aligned Strategic Evaluation of Fire Protection Systems for Improving Fire Safety in Mixed-Occupancy High-Rise Buildings
Abstract: This paper presents a substantially reworked Indian-context evaluation of fire protection systems in a 14-building high-rise sample from Indore. The study reuses the original field dataset but replaces the earlier code mix with an explicitly IS-aligned and NBC-oriented analytical framework. Physical observation, document review and interview inputs were screened against requirements related to means of egress, compartmentation, fire detection and alarm, hydrants and hose reels, extinguishers, emergency lighting, smoke control, …
Published in Journal of Structural Engineering and Management · Vol. 13, Issue 2, 2026 Read article
-
IS-Aligned Strategic Evaluation of Fire Protection Systems for Improving Fire Safety in Mixed-Occupancy High-Rise Buildings
Abstract: This paper presents a substantially reworked Indian-context evaluation of fire protection systems in a 14-building high-rise sample from Indore. The study reuses the original field dataset but replaces the earlier code mix with an explicitly IS-aligned and NBC-oriented analytical framework. Physical observation, document review and interview inputs were screened against requirements related to means of egress, compartmentation, fire detection and alarm, hydrants and hose reels, extinguishers, emergency lighting, smoke control, …
Published in Journal of Structural Engineering and Management · Vol. 13, Issue 2, 2026 · pp. 15–26 Read article
-
A Study on Determination of Seismic Susceptibility in Existing Buildings in Ward No-18 of Dhaka North Using Rapid Visual Screening (RVS) Method
Abstract: The research work presents a comprehensive analysis of the Rapid Visual Screening (RVS) method applied to 200 buildings in Ward No. 18 of Dhaka North City. The study focused on assessing the seismic vulnerability of these structures, categorizing them into damage grades based on the RVS evaluation. Strikingly, the findings revealed that 191 out of the 200 buildings were classified as damage grade 5, signifying severe structural deficiencies. In contrast, …
Published in International Journal of Climate Conditions · Vol. 1, Issue 1, 2024 · pp. 28–37 Read article