Search
186 articles for “detector”
-
Determination of RP-HPLC Method for Safinamide: Its Bulk and Tablet Dosage Form
Abstract: A new method was established for estimation of Safinamide by RP-HPLC method. The chromatographic conditions were successfully developed for the separation of Safinamide by using Agilent C18 column (4.6×150 mm, 5 µ); flow rate was 1 ml/min, mobile phase ratio was Methnol, Acetonitril (60:40), pH 3 (pH was adjusted with orthophosphoric acid), detection wavelength was 235 nm. The instrument used was WATERS HPLC Auto Sampler, Separation module 2695, photo diode …
Published in Research & Reviews: A Journal of Drug Formulation, Development and Production · Vol. 5, Issue 3, 2018 · pp. 1–6 Read article
-
Development and Validation of RP-HPLC Method for Determination of Thermal Degradation Impurity in Macrolide Immunosuppressant Substance and Drug Product
Abstract: The present study describes a simple and stability-indicating reverse phase high-performance liquid chromatography (RP-HPLC) method for the quantification of the thermal degradation impurities of Tacrolimus (FK506) namely Ally ester rearrangement impurity (Impurity R) in Tacrolimus capsules and drug substances. Successful separation of impurity R from Tacrolimus, its other related substances and its tautomers were achieved on a Zorbax XDB C8 (150×4.6 mm, 5 μm) and detector of UV at 210 …
Published in Research & Reviews: A Journal of Drug Formulation, Development and Production · Vol. 3, Issue 1, 2016 · pp. 14–19 Read article
-
A New RP-HPLC Method for Simultaneous Estimation of Atorvastatin and Fenofibrate in Its Bulk and Tablet Dosage Form
Abstract: Objective: A New method was established for simultaneous estimation of Atorvastatin and Fenofibrate by RP-HPLC method. Methods: Chromatographic separations were carried using Phenomenex C18 column (4.6 × 250 mm, 5 µm) column with a mobile phase composition of 0.1 M Ammonium acetate:acetonitrile (60:40) have been delivered at a flow rate of 1ml/min and the detection was carried out using waters HPLC auto sampler, separation module 2695 with PDA detector at …
Published in Research & Reviews: A Journal of Drug Design & Discovery · Vol. 8, Issue 3, 2023 · pp. 12–18 Read article
-
Development and Validation of RP-HPLC Method for Estimation Ertugliflozin in Its Bulk and Tablet Dosage Form
Abstract: Background: This study developed and validated a new, sensitive, appropriate, clear, accurate, and robust reversed-phase high-performance liquid chromatography (RP-HPLC) method for determining safinamide in bulk medication and tablet formulations. An HPLC procedure using a UV detector and the Openlab EZchrome workstation programme was used to separate the samples, as well as a Kromasil C18 (250 mm × 4.6 mm i.d.) 5 μm. At a flow rate of 1.0 mL/min, methanol …
Published in Research & Reviews: A Journal of Drug Design & Discovery · Vol. 9, Issue 1, 2022 · pp. 8–20 Read article
-
Spectroscopic and Chromatographic Methods for Estimation of Voriconazole in Bulk and Pharmaceutical Dosage Forms
Abstract: Rapid, accurate and precise methods have been developed for estimation of voriconazole in bulk and pharmaceutical dosage forms using Ultraviolet (UV) spectroscopy and reverse phase high performance chromatography (RP-HPLC). The λmax selected in UV spectroscopy method was 255 nm and the calibration curve was linear in the concentration range of 2-50 µg/mL with correlation coefficient (r2)>0.99. In RP-HPLC method, the separation was carried out on Kromasil C18 (250 x 4.6mm, …
Published in Research & Reviews: A Journal of Drug Formulation, Development and Production · Vol. 8, Issue 1, 2023 · pp. 33–39 Read article
-
New RP-HPLC Method Development and Validation for Simultanious Estimation and Forced Degradation Studies of Gallic acid and Curcumin in Solid Dosage Form
Abstract: Objective: A New method was established for simultaneous estimation of Gallic acid and curcumin by RP-HPLC method. Methods: Chromatographic separations were performed on an Inspire (4.6 x 150mm, 5m) column with a mobile phase composition of 0.1 percent OPA buffer and Acetonitrile (30:70) delivered at a flow rate of 1 ml/min, and detection was performed on a waters HPLC auto sampler, separation module 2695 with PDA detector 2996 at wavelength …
Published in Research and Reviews: A Journal of Pharmaceutical Science · Vol. 13, Issue 1, 2022 · pp. 7–15 Read article