Shear wall
12 articles · search the full text for this term
-
Review on Comparative Analysis of Lateral Load Response of UG+G+7 Building Using Shear Wall, Bracing and Moment Resisting Frame Systems
Abstract: This review paper provides a relative analysis of lateral load-resisting systems in multi-storey buildings, specifically focusing on high-rise structural configuration. The study synthesizes findings from research Papers to evaluate the performance of shear wall systems, bracing systems, and moment-resisting frame systems under seismic and wind loading conditions. With the rising requirement for safe and efficient urban structures, understanding the behavior of different structural systems under lateral loads has become essential.The …
Published in Journal of Structural Engineering and Management · Vol. 13, Issue 2, 2026 · pp. 61–77 Read article
-
Performance Based Seismic Evaluation of G+12 RCC Structures in Seismic Zone IV with and without Corner Shear Walls Considering Soil Types I, II, and III
Abstract: Seismic behavior of multi-storey buildings is significantly influenced by structural stiffness and supporting soil conditions. This study investigates the seismic response of a G+12 reinforced concrete building by comparing two structural configurations, namely buildings with shear walls and buildings without shear walls, under three soil conditions: Type I, Type II, and Type III soils. The analysis is carried out using the response spectrum method in accordance with IS 1893 (Part …
Published in Recent Trends in Civil Engineering & Technology · Vol. 16, Issue 2, 2026 · pp. 1–14 Read article
-
Comparative Performance Assessment of Shear Wall and Diagrid Systems in an Octagonal Tall High-Rise Building under Seismic and Wind Loads
Abstract: The increasing demand for high-rise structures due to rapid urbanization necessitates the adoption of efficient lateral load-resisting systems to ensure structural safety, stability, and serviceability. This study presents a comparative evaluation of the seismic and wind performance of a Ground plus Fiftystorey high-rise building with an octagonal plan, incorporating different structural configurations such as shear wall arrangements and a diagrid system. A total of six analytical models, including a conventional …
Published in Journal of Structural Engineering and Management · Vol. 13, Issue 2, 2026 · pp. 42–60 Read article
-
COMPARATIVE SEISMIC RESPONSE OF IRREGULAR HIGH-RISE RCC 25 STOREY BUILDINGS WITH AND WITHOUT SHEAR WALLS CONSIDERING P–DELTA EFFECT
Abstract: The seismic performance of high-rise reinforced concrete (RCC) buildings is significantly affected by plan irregularity, lateral stiffness distribution, and second-order (P–Delta) effects. Irregular structural configurations may generate torsional response and increased deformation demand under seismic excitation while geometric nonlinearity further amplifies displacement and internal forces in tall structures . This study presents a comparative seismic assessment of a G+24 storey RCC building having overall plan dimensions of 30,000 mm × …
Published in Journal of Structural Engineering and Management · Vol. 13, Issue 2, 2026 Read article
-
Evaluation of Shear Walls and Bracings in Irregular Buildings Under Seismic Load
Abstract: The structural integrity and stability of irregular buildings under lateral forces such as wind and seismic loads pose significant challenges in modern construction practices. Irregularities in a building & geometry and mass distribution can lead to uneven force distribution, making the structure more vulnerable to lateral displacement and potential failure. To enhance the resilience of such structures, shear walls and bracing systems are commonly employed to improve lateral load resistance. …
Published in Journal of Structural Engineering and Management · Vol. 12, Issue 2, 2025 · pp. 22–28 Read article
-
Analytical and Statistical Analysis of Reinforced Concrete Frame Structure Subjected to Blast Loading
Abstract: Blast loading represents one of the most hazardous and destructive forces that structures may encounter throughout their life span. Understanding and mitigating the effects of such loading is crucial for ensuring the safety and resilience of buildings. This study focuses on analyzing the behavior of reinforced concrete (RC) frame structures when subjected to blast loading, with the aim of informing more robust and resilient building designs. The research specifically examines …
Published in Journal of Structural Engineering and Management · Vol. 11, Issue 2, 2024 · pp. 84–91 Read article
-
Erthquake Response of Shear Wall Integrated Step-Back Set-Back Structures on Sloped Ground
Abstract: The study examines how well step-back set-back structures perform seismically when they are resting on a 27° slope in terms of base shear, maximum story displacement, story drift, and time period. Shear walls 200 mm thick are positioned at various points. The seismic performance of the square plan structure having shear wall at corner locations is presented in this study. The study's findings indicate that the shear wall's position affects …
Published in Journal of Geotechnical Engineering · Vol. 11, Issue 2, 2024 · pp. 22–31 Read article
-
INFLUENCE OF ASPECT RATIO, GEOMETRIC CONFIGRATION AND CONTINUTY ON SHEAR WALL PERFORMANCE
Abstract: This study investigates the dynamic behavior of shear walls in high-rise buildings, focusing on the impact of varying parameters like aspect ratio, geometry, and continuous-discontinuous structures. By accurately identifying and quantifying various loads and conducting comprehensive structural analysis. The high-rise complex features reinforced concrete shear walls designed to resist lateral forces, ensuring safety and stability.This topic is chosen because the dynamic behavior of shear walls in high-rise buildings is critical …
Published in Recent Trends in Civil Engineering & Technology · Vol. 14, Issue 2, 2024 · pp. 26–40 Read article
-
Advancements in Seismic Analysis Based on Shear Walls Composite Materials
Abstract: In this study more than 30 research papers are thoroughly reviewed in the area of Seismic Analysis based on Shear Walls. Seismic performance evaluation is used to assess a construction's seismic behavior in accordance with predetermined performance criteria. These methods have been applied in a number of assessment studies to investigate the seismic behavior of shear wall designs, and their findings have advanced the field overall. Shear wall is works …
Published in Journal of Polymer & Composites · Vol. 12, Issue 5, 2024 · pp. 235–243 Read article
-
A Comparative Evaluation of a 13-story G+ Building with a Soft Storey, Using Pushover Analysis, with a Focus on the Impact of Different Placement of Shear Walls
Abstract: Asymmetrical structures with varying degrees of irregularity have proven to be a significant factor in causing collapses, damage to property, and injury during earthquakes. Despite extensive research on asymmetric buildings, there are currently no established guidelines for multi-story structures of this type. A soft storey, also known as a weak storey, is a level in a structure with insufficient rigidity or ductility to sustain earthquake-induced damage Pushover analysis has been …
Published in Recent Trends in Civil Engineering & Technology · Vol. 12, Issue 3, 2022 · pp. 1–9 Read article
-
Non-Linear Dynamic Analysis of High-Rise Flat Slab Structure with Various Lateral Load Resisting System: Indian Scenario
Abstract: In this technological era, the construction of high-rise flat slab structure is increasing everywhere, due to its major advantages over a conventional beam slab structure. Due to the poor performance of high-rise flat slab structure in higher seismic zones, IS 1893 (Part 1): 2016 discourages the use of flat slab structure in higher seismic zones. The use of high-rise flat slab structure in high seismic region is a risk, because …
Published in Journal of Structural Engineering and Management · Vol. 9, Issue 2, 2022 · pp. 1–12 Read article
-
Analysis of RCC Building with and Without Shear Wall Subjected to Blast Load
Abstract: In recent time we have witnessed number of terrorist activities around the world. In this era of technology, it is easy to target structures such as public building, bridges etc. by blasting them. Sometimes accidental blast during handling or storage may also cause huge damage to the structures. It is need of this time to make structures safe against such loads. Experimental methods are not always feasible hence in this …
Published in Recent Trends in Civil Engineering & Technology · Vol. 11, Issue 3, 2021 · pp. 16–22 Read article