Seismic analysis
8 articles · search the full text for this term
-
Review on Comparative Analysis of Lateral Load Response of UG+G+7 Building Using Shear Wall, Bracing and Moment Resisting Frame Systems
Abstract: This review paper provides a relative analysis of lateral load-resisting systems in multi-storey buildings, specifically focusing on high-rise structural configuration. The study synthesizes findings from research Papers to evaluate the performance of shear wall systems, bracing systems, and moment-resisting frame systems under seismic and wind loading conditions. With the rising requirement for safe and efficient urban structures, understanding the behavior of different structural systems under lateral loads has become essential.The …
Published in Journal of Structural Engineering and Management · Vol. 13, Issue 2, 2026 Read article
-
Performance Based Seismic Evaluation of G+12 RCC Structures in Seismic Zone IV with and without Corner Shear Walls Considering Soil Types I, II, and III
Abstract: Seismic behavior of multi-storey buildings is significantly influenced by structural stiffness and supporting soil conditions. This study investigates the seismic response of a G+12 reinforced concrete building by comparing two structural configurations, namely buildings with shear walls and buildings without shear walls, under three soil conditions: Type I, Type II, and Type III soils. The analysis is carried out using the response spectrum method in accordance with IS 1893 (Part …
Published in Recent Trends in Civil Engineering & Technology · Vol. 16, Issue 2, 2026 Read article
-
Comparative Performance Assessment of Shear Wall and Diagrid Systems in an Octagonal Tall High-Rise Building under Seismic and Wind Loads
Abstract: The increasing demand for high-rise structures due to rapid urbanization necessitates the adoption of efficient lateral load-resisting systems to ensure structural safety, stability, and serviceability. This study presents a comparative evaluation of the seismic and wind performance of a Ground plus Fiftystorey high-rise building with an octagonal plan, incorporating different structural configurations such as shear wall arrangements and a diagrid system. A total of six analytical models, including a conventional …
Published in Journal of Structural Engineering and Management · Vol. 13, Issue 2, 2026 Read article
-
Comparative Seismic Response of Irregular High-Rise RCC 25 Storey Buildings with and without Shear Walls Considering P–Delta Effect
Abstract: The seismic performance of high-rise reinforced concrete (RCC) buildings is significantly affected by plan irregularity, lateral stiffness distribution, and second-order (P–Delta) effects. Irregular structural configurations may generate torsional response and increased deformation demand under seismic excitation while geometric nonlinearity further amplifies displacement and internal forces in tall structures . This study presents a comparative seismic assessment of a G+24 storey RCC building having overall plan dimensions of 30,000 mm × …
Published in Journal of Structural Engineering and Management · Vol. 13, Issue 2, 2026 Read article
-
Analysis of Elevated Liquid Storage Tank on Sloping Ground with Variable Heights
Abstract: Past earthquake events have shown that even well-designed elevated water tanks can suffer severe damage or collapse. Much of this damage occurs due to a limited understanding of the behavior and appropriate selection of supporting systems during the design process. With a large mass concentrated at the top of slender supports, these tanks are especially vulnerable to horizontal seismic forces. Therefore, it is crucial to evaluate the strength and performance …
Published in Journal of Geotechnical Engineering · Vol. 12, Issue 3, 2025 · pp. 16–31 Read article
-
Static and Dynamic Analysis of Conventional, Diagrid and Hexagrid Systems Across Different Storey Heights
Abstract: In structural engineering, multi-storey buildings’ seismic resilience in earthquake-prone areas is crucial. The seismic performance of proposed multi-story buildings with different heights (G+13, G+19, and G+27) is thoroughly examined in this study using traditional structural systems that are octagrid and hexagrid. Under seismic zone III conditions, the study evaluates important parameters such as storey drifts and storey displacements using the Response Spectrum Method. Each structural system's seismic response is assessed …
Published in Journal of Offshore Structure and Technology · Vol. 12, Issue 2, 2025 · pp. 36–47 Read article
-
Advancements in Seismic Analysis Based on Shear Walls Composite Materials
Abstract: In this study more than 30 research papers are thoroughly reviewed in the area of Seismic Analysis based on Shear Walls. Seismic performance evaluation is used to assess a construction's seismic behavior in accordance with predetermined performance criteria. These methods have been applied in a number of assessment studies to investigate the seismic behavior of shear wall designs, and their findings have advanced the field overall. Shear wall is works …
Published in Journal of Polymer & Composites · Vol. 12, Issue 5, 2024 · pp. 235–243 Read article
-
Seismic Analysis of Conventional, Hexagrid and Octagrid Steel Structural Systems
Abstract: The seismic resilience of multi-story buildings in earthquake-prone regions is a critical consideration in structural engineering. This dissertation presents a comprehensive analysis of the seismic performance of proposed multi-story buildings with varying heights (G+10, G+15, and G+20) using conventional, hexagrid, and octagrid structural systems. The study utilizes the Response Spectrum Method under seismic zone Ⅴ conditions to assess key parameters including storey drift, storey displacement, base shear, and overturning moment. …
Published in Journal of Structural Engineering and Management · Vol. 11, Issue 1, 2024 · pp. 26–41 Read article