Indirect bonding
9 articles · search the full text for this term
-
Short Report to Describe the Surface-driven Microfluidic Flow in Fluid Mechanics
Abstract: In this short report, a brief review on surface-driven microfluidic flow is provided. Also, the maskless lithography and indirect bonding technique are used to fabricate a single SU-8 based glass microfluidic device. Dyed ethylene glycol is prepared as working liquid to test the fabricated device. The surface-driven microfluidic flow of dyed ethylene glycol is recorded by a CMOS camera catching 25 frames per second with a corresponding time-scale resolution of …
Published in Recent Trends in Fluid Mechanics · Vol. 9, Issue 4, 2022 · pp. 1–5 Read article
-
Surface-Driven Microfluidic Flow in Fluid Mechanics
Abstract: In this short report, a brief review on surface-driven microfluidic flow is provided. Also, the maskless lithography and indirect bonding technique are used to fabricate a single SU-8 based glass microfluidic device. Dyed ethylene glycol is prepared as working liquid to test the fabricated device. The surface-driven microfluidic flow of dyed ethylene glycol is recorded by a CMOS camera catching 25 frames per second with a corresponding time-scale resolution of …
Published in Recent Trends in Fluid Mechanics · Vol. 8, Issue 3, 2021 · pp. 1–5 Read article
-
Short Experimental Report on Lithographic Technique in Microfluidics
Abstract: In this experimental work, a single SU-8 based glass microfluidic device is fabricated by the maskless lithography and indirect bonding technique. The sealing by indirect bonding technique is perform during the hard baking in maskless lithography. Dyed ethylene glycol is prepared as the working liquid. A CMOS camera catching 25 frames per second with a corresponding time-scale resolution of 0.04 second is used to record the surface-driven microfluidic flow of …
Published in Journal of Microwave Engineering and Technologies · Vol. 8, Issue 3, 2021 · pp. 1–5 Read article
-
Microfluidic Features in Fluid Mechanics for Bioengineering Applications
Abstract: In this work, a single SU-8 based glass microfluidic device is fabricated by the mask less lithography and indirect bonding technique. The sealing is performed by author during the hard baking in maskless lithography. Dyed water is prepared as working liquid in this work. A CMOS camera catching 25 frames per second with a corresponding time-scale resolution of 0.04 second is used by the author to record the surface-driven capillary …
Published in Research and Reviews : A Journal of Biotechnology · Vol. 11, Issue 3, 2021 · pp. 1–4 Read article
-
Polymer Processing in Microfluidics towards the Fabrication of Nanofluidic Systems in Nanotechnology
Abstract: This experimental work reports two individual SU-8 based glass microfluidic devices to be fabricated by maskless lithography along with indirect bonding technique using the steps of SU-8 processing. Dyed water is the selected and prepared working liquid for this work. The CMOS camera is used to record the passive microfluidic flow of dyed water in fabricated devices. In future, this report may be suitable to investigate the nanofluidic flow phenomena …
Published in Journal of Nanoscience, NanoEngineering & Applications · Vol. 11, Issue 2, 2021 · pp. 27–31 Read article
-
Chemical Processing of SU-8 Photoresist to Record the Surface-Driven Microfluidic Flow of Dyed Working Liquid in the Regime of Fluid Mechanics
Abstract: Chemical processing of negative photoresist SU-8 is performed to fabricate a set of three individualSU-8 based glass microfluidic devices inside the cleanroom laboratory. The major steps of SU-8processing are spin coating using a spin coater, soft baking, ultra-violet (UV) exposure, post exposurebaking, development by SU-8 developer, and hard baking. The indirect bonding for leakage-freesealing is used during hard baking to fabricate the microfluidic devices. Author has prepared thedyed water to …
Published in Emerging Trends in Chemical Engineering · Vol. 8, Issue 1, 2021 · pp. 53–57 Read article
-
Experimental Demonstration on Microfluidic Capillary Flow of Red Dye in Photoresist based Glass Microfluidic Devices
Abstract: In this experimental work, a set of three individual SU-8 based glass microfluidic devices are fabricated by maskless lithography and indirect bonding technique in leakage-free conditions. Commercially available red coloured food dye is used as the selected working liquid. The microfluidic leakage in other set of two leaky microfluidic devices is experimentally demonstrated. Microfluidic devices should be fabricated at leakage-free conditions to achieve exact fluid flow characteristics. The effect of …
Published in Journal of Thin Films, Coating Science Technology & Application · Vol. 7, Issue 1, 2020 · pp. 1–7 Read article
-
Microfluidic Flow of the Dyed Aqueous Isopropyl Alcohol in a single SU-8 based Glass Microfluidic Device Fabricated inside the Cleanroom Laboratory
Abstract: A single SU-8 based glass microfluidic device is fabricated by maskless lithography and indirect bonding technique, using author’s own hands-on completely inside the cleanroom laboratory. Dyed aqueous isopropyl alcohol (90% dyed water, 10% isopropyl alcohol) is the prepared working liquid in this work. The surface-driven microfluidic flow of working liquid is recorded by a CMOS camera catching 25 frames per second with a corresponding time-scale resolution of 0.04 second. The …
Published in Journal of Catalyst & Catalysis · Vol. 6, Issue 1, 2019 · pp. 10–13 Read article
-
Experimental Demonstration on the Leakage-Free Surface-Driven Capillary Flow of Red Dye
Abstract: In this work, two individual SU-8 based glass microfluidic devices are fabricated by the maskless lithography and indirect bonding technique. Commercially available red-colored food dye is used as the working liquid. Microfluidic leakage is observed between the glass lid and SU-8 based microchannel substrate due to the improper indirect bonding technique. Leakage-free surface-driven capillary flow is observed due to the proper indirect bonding technique. CMOS camera is used to capture …
Published in Journal of Catalyst & Catalysis · Vol. 5, Issue 3, 2018 · pp. 8–11 Read article