Dyed water
7 articles · search the full text for this term
-
Microfluidic Features in Fluid Mechanics for Bioengineering Applications
Abstract: In this work, a single SU-8 based glass microfluidic device is fabricated by the mask less lithography and indirect bonding technique. The sealing is performed by author during the hard baking in maskless lithography. Dyed water is prepared as working liquid in this work. A CMOS camera catching 25 frames per second with a corresponding time-scale resolution of 0.04 second is used by the author to record the surface-driven capillary …
Published in Research and Reviews : A Journal of Biotechnology · Vol. 11, Issue 3, 2021 · pp. 1–4 Read article
-
Nano-Scale Coating to Demonstrate the Capillary Motion of Dyed Water in a Single PMMA Microfluidic Device towards the Probable Fabrication of nanofluidic Engine-on-a-Chip
Abstract: A single microfluidic device is fabricated by polymethylmethacrylate (PMMA) using the maskless lithography, hot embossing lithography, nano-coating of diamond-like carbon (DLC), and direct bonding technique. A CMOS camera catching 25 frames per second with a corresponding time-scale resolution of 0.04 second is used to record the surface-driven microfluidic flow of dyed water. A comparison is made between the experimental results and analytical solution to determine the diffusion coefficient in this …
Published in Nano Trends – A Journal of Nano Technology & Its Applications · Vol. 22, Issue 3, 2020 · pp. 12–15 Read article
-
Effects of Channel Volume and Channel Aspect Ratio on the Surface-Driven Capillary Flow of Dyed Water in Sudden Expansion Microchannels Fabricated by Polymer
Abstract: In this experimental work, total three individual sudden expansion microchannels (microfluidic devices) are fabricated by polymethylmethacrylate (PMMA) using the maskless lithography, hot embossing lithography and direct bonding technique. Dyed water is prepared and used as the selected working liquid. Channel aspect ratio (channel height/channel width) is defined and used as the structural parameter in this work. Diffusion coefficient is used as the flow parameter. Effect of channel volume on the …
Published in Journal of Nanoscience, NanoEngineering & Applications · Vol. 10, Issue 2, 2020 · pp. 18–24 Read article
-
Experiments to Control the Surface-Driven Microfluidic Flow of Dyed Water in Straight PMMA Microchannels Fabricated by Maskless Lithography, Hot Embossing Lithography and Direct Bonding Technique
Abstract: Total six individual straight microchannels are fabricated by maskless lithography, hot embossing lithography and direct bonding technique using author’s own hands-on completely inside the cleanroom laboratory. Polymethylmethacrylate (PMMA) is the selected polymeric material to fabricate these straight microchannels. Dyed water is prepared as working liquid to record and study the microfluidic flow characteristics inside these fabricated microchannels. Air dielectric barrier discharge (DBD) plasma processing is the surface modification technique in …
Published in Journal of Thin Films, Coating Science Technology & Application · Vol. 7, Issue 1, 2020 · pp. 17–23 Read article
-
Recording of the Surface-Driven Microfluidic Flow of Aqueous Working Liquids in PMMA Microfluidic Devices
Abstract: In this work, the pristine polymethylmethacrylate (PMMA) microchannel surfaces are modified by the air dielectric barrier discharge (DBD) plasma processing, nitrogen plasma treatment, Undoped diamond-like carbon (DLC) coating, and Si-doped DLC coating, to produce the PMMA microfluidic devices having inner walls of different surface wettability. Dyed water and dyed aqueous ethanol (90% dyed water, 10% ethanol) are the selected two aqueous working liquids. The video recording of each surface-driven microfluidic …
Published in Emerging Trends in Chemical Engineering · Vol. 5, Issue 3, 2018 · pp. 24–31 Read article
-
Effect of Surface Modifications on the Meniscus Velocities of Dyed Water in PMMA Microchannels
Abstract: In this work, author has fabricated the polymethylmethacrylate (PMMA) microfluidic devices to study the effect of surface modification techniques on surface-driven capillary flow. Maskless lithography, hot embossing lithography and direct bonding technique are used to fabricate the PMMA microfluidic devices. The effect of static water contact angle on surface- driven capillary flow is studied in the fabricated devices. The effect of the arrays of square PMMA micropillars on surface-driven capillary …
Published in Emerging Trends in Chemical Engineering · Vol. 5, Issue 2, 2018 · pp. 1–4 Read article
-
Microfluidic Flow of Dyed Water in the SU-8 based Glass Devices
Abstract: Two individual SU-8 based glass microfluidic devices are fabricated by the maskless lithography and indirect bonding technique. Dyed water is used as working liquid to record the surface-driven capillary flow in each microfluidic device. In the indirect bonding technique, polymethylmethacrylate (PMMA) dissolved in EC solvent is used as the adhesive material to fabricate the leakage-free microfluidic device. CMOS camera is used as the recording tool in this work. This work …
Published in Research & Reviews : Journal of Physics · Vol. 6, Issue 3, 2017 · pp. 14–17 Read article