Magnetorheological Composite Dampers for Railway Wagon Suspension: Modelling Validation and Performance Analysis
Abstract: Railway wagons encounter continuous vibrations due to track irregularities, resulting in reduced ride comfort and higher dynamic loads. Conventional suspension systems based on springs, hydraulic dampers, or air suspensions provide only limited vibration mitigation. This work investigates the application of magnetorheological (MR) fluid-based dampers, where a polymeric carrier oil (silicone oil) reinforced with carbonyl iron particles serves as a smart composite suspension medium. The MR fluid is synthesized and characterized …
Published in Journal of Polymer & Composites · Vol. 14, Issue 2, 2026 · pp. 43–63 Read article
-
A Seismic Analysis of R.C. Structures Under Tuned Mass Damper System.
Abstract: A Seismic Analysis of R.C. Structures Under Tuned Mass Damper System treats seismic force reduction of multi-storey buildings using embedded dampers. tuned mass damper is investigated. Dynamic analysis was carried out using Etabs to obtain the damped and undamped responses of the structure in terms of deflections at all storeys in order to evaluate the effectiveness of the damping system to reduce the seismic response. The earthquake zone v used …
Published in Journal of Structural Engineering and Management · Vol. 6, Issue 1, 2019 · pp. 28–36 Read article
-
Analytical Study on Optimum Placement and Sizing of X-Plate Metallic Dampers for Seismic Response Control of Multistoried RC Building Frame
Abstract: X-plate metallic damper (XPD) is one device that is capable of sustaining many cycles of stable yielding deformation resulting in a high level of energy dissipation or damping. For quantification of effectiveness of XPD, optimum placement and sizing of XPD are one of the practical interest. This paper investigates effect of placement and sizing of X-Plate damper on a G+3 square shaped building. The most optimal damper placement location pattern …
Published in Journal of Structural Engineering and Management · Vol. 4, Issue 2, 2017 · pp. 6–12 Read article
-
Comparative Study of Seismic Performance of Multistory Symmetrical RC Frame Structure with and Without Dampers
Abstract: This paper investigates the influence of friction dampers on the nonlinear seismic performance of multistory structure. The operational mechanism of these devices is that a large amount of energy inputting to the structure could be absorbed and the displacement of the structure is reduced. For this purpose, four types of frames are investigated with dampers at different locations. Three types of natural time histories are used for the nonlinear seismic …
Published in Journal of Structural Engineering and Management · Vol. 4, Issue 2, 2017 · pp. 1–5 Read article
-
Parametric Study of Tuned Liquid Damper on Multistorey Frame Unit
Abstract: Swimming pools in a skyscraper are not only an entertainment facility but also a boon of a structural design engineer to curb the impact of lateral forces such as wind, earthquake, etc. The usage of swimming pools as liquid tuned damper is a cost effective alternative without having any additional component within the structure. Much of the research to damp the vibration of the structure like base isolation, bracing, in-fills …
Published in Journal of Structural Engineering and Management · Vol. 3, Issue 3, 2016 · pp. 46–54 Read article
-
Analysis of Multistoried RCC Building with Dampers as Energy Dissipation System using ETABS
Abstract: In order to have earthquake resistant structures, fluid viscous dampers have been used.In present study G+7 Story buildings is compared with the seismic effect of structure with dampers and without dampers. In the present study the software ETABS 2017 have been used. Using response spectrum analyses the response of the RC building considered in the present study is evaluated and compared with and without FVD. This study investigates the influence …
Published in Recent Trends in Civil Engineering & Technology · Vol. 10, Issue 2, 2020 · pp. 1–5 Read article
-
Seismic Retrofitting of Floating Column Building with Fluid Viscous Dampers and Structural Bracings by using Fast Non-linear Time History Analysis
Abstract: In some of the building structures, even in the newly constructed one, floating columns are used to achieve an aesthetic view or to satisfy the space requirement criteria of building areas like reception lobbies, parking spaces, conference rooms in malls etc. With the use of proper design considerations, buildings built with floating columns, which otherwise are not advised by the codes, can withstand vertical loads, i.e., gravity loads and live …
Published in Journal of Offshore Structure and Technology Read article
-
Effect of Viscoelastic Dampers on Progressive Collapse Resistance of RC Building
Abstract: Natural as well as man-made hazards may cause the failure of the primary load bearing members of buildings. The spread of an initial local failure from element to element, eventually result into the collapse of an entire structure or a large part of it, which is known as Progressive Collapse. Progressive collapse initiates when one or more primary load bearing elements get fails causing failure of the entire structure. It …
Published in Journal of Structural Engineering and Management · Vol. 4, Issue 1, 2017 · pp. 27–34 Read article
-
Parameter Identification of Vibrating MIMO Mass-Spring-Damper Mechanical Systems with Coulomb Friction
Abstract: This study presents a time-domain method for identifying parameters in multi-degree-of-freedom (DOF) linear mass-spring-damper systems that include Coulomb friction, where the friction coefficient varies within a limited range, using measurements of position and control force. For mass identification in single-degree-of-freedom (DOF) vibrating mechanical systems with stiffness and no damping but Coulomb friction, the friction term is eliminated by first derivative processing. In addition, the identification of the coefficient of friction …
Published in International Journal of Mechanical Dynamics and Systems Analysis · Vol. 3, Issue 1, 2025 · pp. 20–34 Read article
-
Effectiveness of Semi-Active Variable Stiffness Tuned Mass Damper for Seismic Load Using LQR Control
Abstract: In this study, effectiveness of semi-active variable stiffness tuned mass damper in reducing seismic response of 10-story frame structure is evaluated. The variable stiffness device, comprising four spring, having rhombus configuration, adapted from literature is attached to the tuned mass damper. A control algorithm using state space form of governing equation of motion is developed. LQR controller is employed to obtain control force based on displacement and velocity response feedback. …
Published in Recent Trends in Civil Engineering & Technology · Vol. 10, Issue 1, 2020 · pp. 11–11 Read article
-
Comparative Study on Damper and Shear Wall in Earthquake Analysis for Multi-storey Structure
Abstract: The earthquake is the one of the most devastating natural hazards that causes serious Structural damage and also great loss of life. Structural irregularities or asymmetrical plan are commonly found in constructions and structure due to the architectural demand .this research work focused on symmetric and asymmetric multi-storey building under the action of earthquake with and without damper and shear wall. The load combination given in IS-1893-2002 (Part-1.). The performance …
Published in Journal of Structural Engineering and Management · Vol. 4, Issue 2, 2017 · pp. 13–21 Read article
-
X Plate Damper for Seismic Response Control of the Building
Abstract: The building system causes excessive vibrations during the seismic event which can lead to the complete collapse of a building, bridges etc. resulting in damage to the structure. Hence, the safety of the structures is essential to keep the building functional during and after the effects of the earthquake. To overcome these damages, additional energy dissipation systems are considered for the seismic protection of the building. The aim of the …
Published in Journal of Water Resource Engineering and Management · Vol. 6, Issue 1, 2019 · pp. 19–23 Read article
-
Wind and Earthquake Mitigation: The Impact of Dampers on Tall Structures
Abstract: This paper provides an in-depth examination of the effects of both earthquake and wind loading on high-rise buildings situated across various terrain categories and seismic zones. The research underscores the critical importance of accounting for lateral loads in the design of reinforced concrete structures, as this consideration is essential for maintaining structural stability and ensuring the safety of occupants. The study focuses on identifying the critical design loads for multistory …
Published in Journal of Structural Engineering and Management · Vol. 11, Issue 2, 2024 · pp. 75–83 Read article
-
Electromagnetic Damping in Shock Absorbers
Abstract: In the shock absorber, springs are used as dampers which hold the weight of vehicle, rider(s), and cargo. After certain interval of time, the stiffness of the spring gets reduced due to some parameters e.g. load, oscillation, etc.; because of that, there will be imbalance in the vehicle, which would lead to loss of control and hence major accident. In order to prevent such untorn events, I will present some …
Published in Journal of Microcontroller Engineering and Applications · Vol. 4, Issue 1, 2017 · pp. 12–16 Read article
-
Vibration control of a Plan irregular RC framed structure under seismic excitations with the help of TMD along with bracings
Abstract: The study of dynamic behavior of high-rise structures is immensely important as the dynamic response of the structures due to natural forces like seismic forces, wind forces etc. may result in structural failure. An unsymmetrically located shear wall or similar kind of stiff element may cause the structure to have plan irregularity. Such type of plan irregularity in high rise structure can induce the torsional displacements in the structure subjected …
Published in Journal of Structural Engineering and Management · Vol. 9, Issue 3, 2022 · pp. 1–8 Read article
-
Experimental Study on Effectiveness of TMD in Reducing Torsional Motion under Harmonic Base Motion
Abstract: AbstractAsymmetry in the building could arise due to unsymmetrical distribution of mass, stiffness, damping and/or strength characteristics. The earthquake response of asymmetric buildings is characterized by coupling between translational and rotational degrees of freedom (dofs). This paper includes an experimental analysis of one storied asymmetrical building frame subjected to harmonic motion with and without tuned mass damper (TMD). Experimentation is done on a shake table and readings were recorded. The …
Published in Journal of Structural Engineering and Management · Vol. 4, Issue 3, 2017 · pp. 13–16 Read article
-
Differential Model of Wave Vibration on Strings and Rods
Abstract: Vibration, as a physical phenomenon, plays a multifaceted role in both natural and engineered systems. Beyond its essential contribution to communication through sound and speech, it finds critical application in various technological domains. For instance, in the design of stringed musical instruments such as violins and guitars, precise manipulation of string vibrations defines tonal quality and musical resonance. Similarly, metal rods in tuning forks exhibit vibrational properties that are finely …
Published in Research & Reviews : Journal of Physics · Vol. 14, Issue 1, 2025 · pp. 17–21 Read article
-
Comparative Seismic Analysis of Multistorey Core in Core Structure Using Beam, Fluid
Abstract: The main objective of this paper is to analyze and study the comparative analysis of multistorey core in core structure with beam, Fluid viscous dampers and bracings using Etabs. Core in core structures, also known as dual core structures, are a structural design concept employed in high-rise buildings to enhance their structural performance and increase resistance to lateral loads such as wind and earthquakes. The concept of core in core …
Published in Journal of Polymer & Composites · Vol. 12, Issue 2, 2024 · pp. 212–223 Read article
-
Enhancing Chatter Resistance in Deep Hole Boring Through Modified Tool Design: A Study on Impact of Length-To-Diameter (L/D) Ratio
Abstract: Deep hole boring is a specialized machining process crucial for creating precise bores with high length-to-diameter (L/D) ratios, particularly vital in aerospace, automotive, and oil and gas industries. The L/D ratio is pivotal for stability and performance. Chatter, a detrimental vibration phenomenon, is a significant concern in deep hole boring, influenced by the L/D ratio. Higher L/D ratios increase chatter, leading to poor surface finish and reduced tool life. Longer …
Published in International Journal of Machine Systems and Manufacturing Technology · Vol. 2, Issue 2, 2024 · pp. 24–33 Read article
-
Effect of Carbonyl Iron Particle Concentration on The Printability and Stiffness of Magnetorheological Elastomer Filaments
Abstract: Magnetorheological elastomer (MRE) are increasingly valued for their field-responsive mechanical properties, making them ideal for adaptive components in automotive, aerospace, and vibration control systems. However, conventional mould-based fabrication methods limit design flexibility, produce excess material waste, and are unsuitable for complex or customized geometries caused challenges that have hindered broader industrial adoption. Although 3D printing offers a compelling alternative, research on printable MRE filaments remains limited, particularly regarding how carbonyl …
Published in Journal of Polymer & Composites · Vol. 13, Issue 5, 2025 · pp. 310–317 Read article