Search
8 articles for “copper tubes”
-
CFD Analysis of Electric Vehicles Battery Pack: A Research Study
Abstract: The goal of the project is to keep the battery temperature within the specified range and to improve the battery pack's performance under different temperature settings. To achieve these goals, we employ software to analyze the data and provide the necessary output. With model-based design, you can understand the dynamic behavior. For this project, a CAD model was produced with Creo Parametric. We used the STAR CCM+ Software for analysis …
Published in International Journal of Electrical Power and Machine Systems · Vol. 1, Issue 2, 2023 · pp. 28–32 Read article
-
Investigation of Forced Convection Heat Transfer Efficiency Using Cuo/Water Nanofluid in A Concentric Tube Heat Exchanger with Helical Coiled Insert
Abstract: An apparatus that uses nanofluid to transport heat is called a heat exchanger. This uses a nanofluid as the working fluid. One can make nanofluid hanging nanoparticles in liquids such as petroleum products, water, oil, ethylene glycol, fluorocarbons, etc. Forced convection heat transfer using CuO/water as a Nanofluid and distilled water as the base fluid has been examined in a concentric tube heat exchanger with helical coiled insert. Tests on …
Published in Journal of Experimental & Applied Mechanics · Vol. 15, Issue 2, 2024 · pp. 27–41 Read article
-
Enhancing the Performance of Evacuated Tube Heat Pipe Solar Collector Using CuO Nanofluid
Abstract: Renewable energy is an important component of sustainable development technologies that meet current demands without risking future generations' ability to meet their own. Due to fast expanding energy consumption and environmental concerns, many international scholars are seeking an alternate approach to fulfill future energy demand. Due to its abundance and pure nature, solar energy appears to be the most enticing option in this case. Because of their ease of use, …
Published in Journal of Polymer & Composites · Vol. 11, Issue 8, 2023 · pp. 393–407 Read article
-
Techno-economic Assessment of a Domestic Refrigerator with Aluminium-based Suction Line and Capillary Tube
Abstract: The present work reports the experimental performance evaluation of aluminum suction line-based domestic refrigerators. Furthermore, it compared domestic refrigerators with conventional copper capillary tubes and suction lines using R600a as a refrigerant. Performance parameters: energy consumption, ice-making time, and pull-down time was reduced significantly compared to conventional copper suction and capillary tube. Refrigerants having Ambient temperature for ice making test and pull down were initially set at 43°C and that …
Published in Journal of Polymer & Composites Read article
-
Thermo-hydraulic Performance of Annular-Finned Double-Pipe Heat Exchanger: Numerical and Experimental Investigation of Metallic and Polymer Composite Tube Wall Materials
Abstract: Double-pipe heat exchangers are central to the process industries — dependable, easily maintained, and straightforward to fabricate. Their conventional form relies on metallic tube materials, most often copper or stainless steel. Both metals conduct heat well, but they are dense, prone to corrosion in aggressive service environments, and increasingly at odds with the light-weighting goals that drive modern system design. Fibre-reinforced polymer composites, epoxy-based materials, and thermally enhanced thermoplastics such …
Published in Journal of Polymer & Composites · Vol. 14, Issue 3, 2026 · pp. 891–909 Read article
-
Optimization of An Intercooler Used in Multi Stage Compressor Using with and Without Baffels
Abstract: Thermal and CFD analysis is done on the intercooler. CFD analysis is done under different boundary conditions. The materials considered for shell and tube intercooler are Aluminum, Titanium and Copper for thermal analysis and compared for better material. The input of heat transfer coefficient for thermal analysis is taken from output of CFD analysis. The intercooler's pressure gradients, temperature distributions, and fluid flow patterns can all be understood using CFD …
Published in International Journal of Energy and Thermal Applications · Vol. 2, Issue 1, 2024 · pp. 1–8 Read article
-
Enhanced Heat Transfer in Double Pipe Heat Exchanger with Circular Fins Using Copper Nanofluid and Twisted Tape Inserts: A Computational Study
Abstract: The enhancement of convective heat transfer in a double-pipe heat exchanger utilizing circular finned twisted tape inserts and helical screw-tapes with centre rods, in conjunction with copper oxide nanofluid as the heat transfer medium was studied in this project. Computational Fluid Dynamics (CFD) simulations were conducted across Reynolds numbers ranging from 500 to 5000 to analyse heat transfer characteristics. The investigation focuses on Nusselt number improvement and friction factor analysis …
Published in Journal of Thermal Engineering and Applications · Vol. 12, Issue 1, 2025 · pp. 11–22 Read article
-
Investigation of Exergy and Energy with Fibre Reinforced Plastic Composite (FRP) Tube Based Solar Still using PCM material via Theoretical and Computational Approach
Abstract: A FRP (Fibre Reinforced Polymer) material-based solar still is an advanced design approach in solar desalination systems, where the traditional construction materials (like metal or concrete) are replaced or enhanced with FRP composites. A FRP composite material tubular solar still is a lightweight desalination equipment with a substantial condensing area in comparison to other types of solar stills. Nonetheless, their effectiveness is often limited by fluctuating climatic circumstances. This study …
Published in Journal of Polymer & Composites · Vol. 14, Issue 1, 2026 · pp. 66–78 Read article