Search
10 articles for “Synchronous references frame control”
-
Analysis of Three Phase AC-DC Front End Converter with Vector Control
Abstract: The revolution in power electronics has opened in last few years widespread use of power converters of different power rating from few Watts to Mega-Watts. 3 phase AC-DC converters (Controlled rectifier) are most widely used power converters as the distributed electric power is AC supply, while the applications based on DC supply as well as variable frequency AC supply, need conversion of AC supply into DC supply. Large current harmonics …
Published in Journal of VLSI Design Tools and Technology · Vol. 11, Issue 3, 2021 · pp. 19–30 Read article
-
Performance Comparison of Control Approaches for Improving Power Quality by DSTATCOM
Abstract: Power quality is very important consideration for electrical supply system. A number of methods like active-passive filters, dynamic voltage restorer, distribution static compensator (DSTATCOM) etc; are used to compensate the power quality problems like harmonics, voltage sag and swell, load balancing and others. This paper presents performance comparison of two control strategies used for DSTATCOM to mitigate the problems of harmonics in distribution network. The DSTATCOM, a shunt connected device …
Published in Journal of Power Electronics and Power Systems · Vol. 6, Issue 1, 2016 · pp. 26–33 Read article
-
Simulation and Performance Based Comparison of Artificial Intelligence Based Shunt Active Power Filter in High Frequency Aircraft System for Power Quality Improvement
Abstract: Synchronous reference frame strategy for extracting reference currents for shunt active power filters have been optimized by using fuzzy logic control and adaptive tabu search algorithm respectively; their performances have been compared. The acute analysis of comparison of the compensation capability based on THD and speed will be done and recommendations will be given for the choice of technique to be used. The simulated results using MATLAB model are shown …
Published in Trends in Electrical Engineering · Vol. 6, Issue 1, 2016 · pp. 32–41 Read article
-
ANN-Based Adaptive Rotor Current Control for DFIG Wind Systems: A Comparative Dynamic Analysis
Abstract: The variability of rotor current management in Doubly Fed Induction Generator (DFIG)-based wind energy conversion systems is crucial for maintaining stability in power extraction under fluctuating wind and grid circumstances. Traditional proportional-integral (PI) controllers, despite their ease of use, frequently exhibit diminished performance when faced with parameter uncertainty, nonlinear behaviors, and rapid wind fluctuations.This paper presents an adaptive rotor current control strategy, which is an Artificial Neural Network (ANN)-based approach …
Published in Journal of Power Electronics and Power Systems · Vol. 16, Issue 1, 2026 · pp. 41–53 Read article
-
Harmonic Mitigation in Shunt Active Power Filter Regulation Approaches with Synchronous Reference Frame: An Extensive Analysis
Abstract: The Shunt Active Power Filter (SAPF) is discussed in this work as a means of removing line-side current harmonics. The Voltage Source Inverter (VSI) topology serves as the foundation for the Active Power Filter. It resolves the power system's harmonic current issue. Additionally, it balances the load on three phases and compensates for reactive power (if load is unbalanced). After measuring load current, it switches to the dq0 coordinate system. …
Published in Journal of Microcontroller Engineering and Applications · Vol. 10, Issue 3, 2023 · pp. 6–15 Read article
-
Adaptive Hysteresis Band Current Controller for the Shunt Active Power Filter Using the d-q0 Reference Frame Theory
Abstract: Recent wide spread applications of power electronic equipment has caused an increase of the harmonic disturbances in the power systems. The nonlinear loads draw harmonic and reactive power components of current from AC mains. Here an adaptive hysteresis band current controlled shunt active power filter is presented to eliminate harmonics and to compensate the reactive power of three-phase rectifier. This current controller changes the hysteresis bandwidth according to modulation frequency, …
Published in Journal of VLSI Design Tools and Technology · Vol. 10, Issue 2, 2020 · pp. 1–7 Read article
-
Design and Control of Three Phase Grid Connected Solar PhotoVoltaic Power System
Abstract: As the world power utilization quickly increments with populace development, new power era limits are obliged to cover that request. So there is requirement for force era utilizing renewable sources. Henceforth photovoltaic system is actualized to tie with the force framework. Keeping in mind the end goal to concentrate greatest force yield from PV framework proficiently, MPPT system is used. A DC-DC converter utilizes voltage source inverter which is controlled …
Published in Journal of Power Electronics and Power Systems · Vol. 5, Issue 1, 2015 · pp. 20–32 Read article
-
Developing a Model in Matlab/Simulink Environment for Induction Motor Considering Core Loss and Stray Load Loss
Abstract: This paper focuses on a Matlab/Simulink model of a squirrel-cage induction motor with consideration of core loss and stray load loss. This model is based on some mathematical expressions and also described through an equivalent circuit including core loss and stray load loss. The model of induction motor has been developed based on the state space equations in a synchronously rotating reference frame, where core loss and stray load losses …
Published in Trends in Electrical Engineering · Vol. 4, Issue 2, 2014 · pp. 1–12 Read article
-
Strengthening Low Voltage Ride-Through in Wind Energy Systems: A Comparative Study of DVR and STATCOM
Abstract: This study looks at the various methods used to improve the low-voltage ride-through (LVRT) capabilities of wind turbine systems (WT) that are based on double-fed induction generators (DFIG). The Type-III WT machine, which is mostly based on DFIG, is instantly connected to the grid without the digital power interface, making the terminal voltage or reactive electricity output unmanageable. This is because the world utilizes between 20% and 25% of renewable …
Published in Journal of Power Electronics and Power Systems · Vol. 14, Issue 3, 2024 · pp. 47–62 Read article
-
Power Quality Enhancement in Distribution System using D-STATCOM
Abstract: New solutions based on power electronics have been developed to safeguard commercial and industrial clients against power quality issues on the electrical distribution system, referred to as Custom Power Products. Custom power devices are classified into three categories by their structures such as dynamic voltage regulator (DVR), distribution static compensator (STATCOM) and unified power quality compensator (UPQC).The Distribution Static Compensator (D-STATCOM), one of the custom power product, is a shunt-connected …
Published in Recent Trends in Electronics Communication Systems · Vol. 8, Issue 2, 2021 · pp. 17–22 Read article