Search
16 articles for “Stent”
-
Complications and Management of Forgotten Ureteral Stent: A Case Report
Abstract: Double J Ureteric stents are the most used devices in the field of the urology for the purpose of establishing and maintaining the patency of ureter. They are also associated with a number of complications including infection, migration of the stent and encrustation leading to the formation of stone. Indwelling of stent for longer duration is associated with greater degree of these complications. We present a case of 55 years …
Published in Research and Reviews : A Journal of Medical Science and Technology · Vol. 11, Issue 2, 2022 · pp. 30–35 Read article
-
Drug Eluting Stents Alter the Inflammatory Biomarkers after One Week of Stent Implantation in Patients with Ischemic Heart Disease: Gender-Based Study
Abstract: Angioplasty is a successful antianginal therapy. Drugs coated on the surface of drug eluting stents (DESs) are potent antimitotic agents that strongly inhibit smooth muscle proliferation and inflammatory process. This study aimed to prove that DES are released into the circulation and induced anti-inflammatory effect which is gender based beyond the local effect on the coronary artery via determination of the circulating levels of interleukin-6 (IL-6) and high sensitivity C-reactive …
Published in Research and Reviews: A Journal of Medicine · Vol. 6, Issue 2, 2016 · pp. 1–8 Read article
-
Design and Analysis of Smart Stents Using MEMS Pressure Sensors
Abstract: In modern day medicine, stents are a commonly used device for patients with cardiovascular diseases.There is however no accurate method of monitoring its working and ensuring that the stent is able to prevent any further blockages. Stents can also cause issues like restenosis and thrombosis, which if not treated immediately can have serious repercussions for the patient. This project aims at understanding,modelling and developing a smart stent which can resolve …
Published in Journal of Mechatronics and Automation · Vol. 9, Issue 2, 2022 · pp. 31–45 Read article
-
Development of Biodegradable Stents from Polymeric Composites for Cardiovascular Applications
Abstract: Cardiovascular diseases are still one of the leading health complications in the world, and coronary artery disease remains one of the toughest ones to crack. The introduction of stent implantation in interventional cardiology is a breakthrough concept which helps to restore blood flow and maintain patency of the arteries. On the other hand, long-term results of bare-metal stents and drug-eluting stents indicate the presence of complications, such as in-stent restenosis, …
Published in Journal of Polymer & Composites · Vol. 14, Issue 4, 2026 · pp. 181–191 Read article
-
Randomized Clinical Study on Dissolution of Urinary Catheters and Stents Encrustation by an Ayurvedic Compound
Abstract: Encrustation, a crust or hard coating on the surface of urinary catheter and stents, is developed due to the formation of biofilm. Encrustation causes blockage of urinary catheter and leads to reflux of urine, increases renal pressure and ultimately damages renal parenchyma tissues. Present clinical study was designed to evaluate the dissolution activity of an Ayurvedic compound on catheter and stent encrustation and to study the changes seen in serum …
Published in Research and Reviews : A Journal of Medical Science and Technology · Vol. 2, Issue 3, 2013 · pp. 12–24 Read article
-
Achieving Surgical Accuracy in Implant Dentistry Using a CAD/CAM Stent: A Case Report
Abstract: Surgical accuracy is of utmost importance in implant dentistry as one of the most common aetiology of implant failure is related to incorrect placement. The surgical aspect of implant placement is vital to the stability, support and retention of the prosthesis to be placed later. CAD/CAM in dentistry has established strong footing in the field of Oral Implantology. The fabrication of a stent to guide the implant drill using CAD/CAM …
Published in Research and Reviews: A Journal of Dentistry · Vol. 8, Issue 1, 2017 · pp. 1–4 Read article
-
Overview of Recent Advancement of Nano Stent in Pharmaceutical Application
Abstract: Interventional cardiology has witnessed remarkable progress with the evolution of nanotechnology, leading to the development of nanostents. Nanostents, characterized by their nanoscale features and innovative materials, have emerged as a cutting-edge solution for addressing the limitations associated with traditional stent technologies. This thorough analysis examines the most recent developments in the design, manufacture, and use of nanostents, emphasizing how they may completely transform vascular interventions. The first section of the …
Published in Trends in Drug Delivery · Vol. 11, Issue 1, 2024 · pp. 22–43 Read article
-
Advances in Polymer Chemistry for Coronary Artery Disease
Abstract: Coronary artery disease (CAD) remains the leading cause of morbidity and mortality worldwide, driving ongoing innovation in therapeutic materials and device design. Polymer chemistry has emerged as a cornerstone in the development of advanced cardiovascular interventions, offering versatile platforms to improve the safety, efficacy, and functionality of implantable devices. This review explores recent advances in the synthesis and application of biodegradable and biostable polymers, focusing on their roles in drug-eluting …
Published in Journal of Polymer & Composites · Vol. 13, Issue 6, 2025 · pp. 710–716 Read article
-
A Case Report of Advanced Periampullary Carcinoma: Palliative Chemotherapy Following Whipple’s Surgery
Abstract: This case report delves into the complex management of a 60-year-old female patient diagnosed with Stage 4 periampullary carcinoma, encompassing the pancreatic head. Presenting with difficulty in eating, diagnostic investigations, including ERCP, confirmed the diagnosis, leading to Whipple's surgery. Postoperatively, liver metastasis was identified, prompting palliative intervention through stenting and the initiation of a GEMOX chemotherapy regimen. The patient responded favorably to the initial chemotherapy cycle, leading to a planned …
Published in Research and Reviews: Journal of Oncology and Hematology · Vol. 13, Issue 1, 2024 · pp. 1–6 Read article
-
Comprehensive Perspective on Coronary Heart Disease: A Review
Abstract: The study explores intricate links between infections, inflammation, and coronary heart disease (CHD), emphasizing their multifaceted contributions to cardiovascular complications. It identifies infections as key players in atherosclerosis, a pivotal element in CHD development, with high antibody levels to specific pathogens as potential risk factors. The article highlights the role of the immune response and elevated C reactive protein (CRP) levels in amplifying infection-related CHD risks and recognizes smoking as …
Published in Research and Reviews: A Journal of Neuroscience · Vol. 14, Issue 1, 2024 · pp. 26–40 Read article
-
Clinical experience with Ayurvedic Treatment in Case of Rheumatoid Arthritis – Ayurvedic review and Case study
Abstract: Rheumatoid arthritis is the most found inflammatory auto immune disease with unknown etiology. Many clinical features and treatment strategies of RA are associated with multiple joint diseases. The clinical phenotype of Rhematoid arthritis is a symmetrical, deformed polyarthritis of small and large joints, which is often associated with features of the disease. The treatment typically involves ongoing management with periods of worsening symptoms followed by periods of improvement. Features of …
Published in Research and Reviews : A Journal of Ayurvedic Science, Yoga and Naturopathy · Vol. 11, Issue 2, 2024 · pp. 1–8 Read article
-
How do Polymer-derived Implants Influence Patient-Reported Outcomes (PRO) in Cardiovascular and Orthopaedic Procedures
Abstract: Implants derived from polymers have surfaced as adaptable substitutes for conventional metallic devices in cardiovascular and orthopedic treatments because of their adjustable mechanical characteristics, biocompatibility, radiolucency, and ability for surface alteration. This systematic review assesses the impact of polymer-based implants such as PEEK, UHMWPE, bioresorbable polymer scaffolds, and drug-eluting systems on outcomes reported by patients (PROs). Findings from 42 qualifying studies show overall positive impacts on pain alleviation, functional recovery, …
Published in Journal of Polymer & Composites · Vol. 14, Issue 1, 2026 · pp. 1821–1834 Read article
-
Polymers and others Advance Materials: A State-of-the-Art Review
Abstract: Developing emerging technologies requires pushing the boundaries of material science. Right now, conventional neat polymers simply do not last long enough in the field. They suffer from sudden mechanical failure, struggle with thermal instability, and throwaway disposal methods have created a massive environmental crisis. To tackle these exact issues, this review provides a critical evaluation of two rapidly growing solutions: sustainable bio-composites and self-healing polymer systems. Rather than offering a …
Published in Journal of Polymer & Composites · Vol. 14, Issue 3, 2026 · pp. 108–119 Read article
-
A Review on Current Status of Biodegradable Surgical Implant Materials
Abstract: Since many years, inert metals such as stainless steel, cobalt-chromium and titanium alloys have been the primary biomaterials used for load bearing applications. In order to these metallic implants such as pins, screws and plates for repairing the defects have to be removed by secondary surgery once the bone tissue is healed, which will increase the morbidity, pain and cost. Hence conventional metallic biomaterials are biocompatible but not biodegradable. At …
Published in Journal of Instrumentation Technology & Innovations · Vol. 10, Issue 3, 2020 · pp. 5–15 Read article
-
Ileal Ureteral Substitution for Long Ureteric Structure/Segment Loss by Yang-Monti Technique. A Single Centre Experience
Abstract: A new technique for replacing the ureter based on the Yang-Monti principle is introduced to overcome the drawbacks of the classic ileal ureter. Between January 2007 and January 2014, ureteral replacement by ileum was indicated in nine patients, long or multiple strictures due to tuberculosis (6), retroperitoneal tumor (1) and iatriagenic ureteric injury during ureteroscopic (2). Exclusion criteria included patients with inflammatory bowel syndrome or irradiated bowel or a non-functioning …
Published in Research and Reviews: A Journal of Medicine · Vol. 5, Issue 3, 2015 · pp. 6–11 Read article
-
Thermo-Responsive Polymer Blends for Minimally Invasive Medical Procedures
Abstract: Thermo-responsive polymer blends have become a key new class of biomaterials for the minimally invasive medical procedure. They offer precision, flexibility and greater patient safety. These smart materials undergo a change of physical/ mechanical properties relative to temperature difference in the body, limiting tissue trauma and increasing effectiveness of the procedure. Their adjustable sol-gel behavior, shape-memory effects and reversible volume change provides an opportunity for their precise delivery through catheters, …
Published in Journal of Polymer & Composites · Vol. 14, Issue 4, 2026 Read article