Search
8 articles for “MVA”
-
Operative Protection Fortitude for Agip 1x15 MVA, 33/11KV Injection Substation
Abstract: The Electrical Power System generally consist of the Generation, transmission and distribution and this system require an adequate protection in it layers of operation to help protect electrical loads and equipment from damaging as to ensure healthy and quality power supply in the power system. The fault associated with this substation are short circuits, overloads, phase unbalance/imbalance, poor usage of protection which in turns causes regular trips/damage on equipment at …
Published in Journal of Electronic Design Technology · Vol. 13, Issue 3, 2022 · pp. 1–8 Read article
-
A Case Study: Diagnostic Testing of 16 MVA Power Transformer
Abstract: In this study describes the industrial research of tan delta test of power transformer (16 MVA 33/11 kV). In diagnostic test measurement, we check the insulation quality of power transformer. Transformer insulation quality is tested by insulation resistance test, tan delta and dissipation factor testing. In this article, we discussed about transformer tan delta test and comparison of transformer tan delta test result of after and before overhauling process. This …
Published in Journal of Power Electronics and Power Systems · Vol. 9, Issue 2, 2019 · pp. 1–4 Read article
-
A Comparative Study of MVA vs. EVA in Pregnancy Termination upto 10 Weeks of Gestation
Abstract: We share our research project, undertaken by a small institutional study group lead by myself, towards completion of my specialist training program of Masters in Obstetrics & Gynaecology. The study was undertaken after due approval. This study is motivated and is based on set of previous studies done in various institutions of excellence, worldwide and may resemble to some study results published elsewhere. However, due credit has been given to …
Published in Research and Reviews: Journal of Oncology and Hematology · Vol. 3, Issue 1, 2014 · pp. 6–10 Read article
-
Protection System Design for Power Distribution System in the Presence of Distributed Generation
Abstract: Investigation was carried out on transformer and bus-bar protection of feeder 1,3,4&6 networks of specially two selected Communities in Egi clan of Ogba Kingdom of Ogba/Egbema/Ndoni Local Government Area of Rivers State such as obagi and oboburu communities respectively. Addressing the three aspects in the design of protection system by determining protection device locations, determining protection device settings, coordination and also mathematical modeling of protective device using MATLAB software for …
Published in Recent Trends in Electronics Communication Systems · Vol. 8, Issue 2, 2021 · pp. 1–16 Read article
-
CRISPR, Recombinant DNA, and LAMP-Based Platforms for Monkeypox: Emerging Tools for Diagnosis and Therapeutic Development
Abstract: Monkeypox, a zoonotic viral infection caused by the Monkeypox virus of the Orthopoxvirus genus, has recurred as a worldwide public health concern after recent outbreaks outside of its classical endemic areas in Central and West Africa. The resurgence has demanded a thorough reassessment of its epidemiology, mode of transmission, and clinical presentation. In light of these challenges, recombinant DNA technology (rDNA) has emerged as a candidate for developing vaccines, diagnostics, …
Published in International Journal of Virus Studies · Vol. 3, Issue 1, 2026 · pp. 7–28 Read article
-
Mitigation of Magnetizing Inrush Current for Unloaded Three Phase Electrically Coupled Power Transformers involving Remanence Effect using Distributed Asymmetrical Winding Configuration
Abstract: This paper demonstrates a novel approach to mitigate the magnetizing inrush current of a coupled unloaded transformer to a considerable extent having had the residual magnetism present in its core with the aid of a modern distributed asymmetrical winding configuration alike from the conventional methods. The proposed method has been analyzed on Power transformer with different configuration of winding, core design arrangement while feeding from the mains to star and …
Published in Journal of Power Electronics and Power Systems · Vol. 6, Issue 2, 2016 · pp. 89–99 Read article
-
Condition Monitoring of Power Transformer Using Different Techniques
Abstract: Transformer is one of the key equipment of the power system. Power rating of the transformers varies from KVA to several hundreds of MVA. The transformer is an expensive equipment of the power system. Failures of transformer usually lead to substantial profit loss to the utility, potential environmental damage, explosion and fire hazards and expensive repairing or replacement costs; thus, it is desirable that the maximum service life of transformer …
Published in Trends in Electrical Engineering · Vol. 6, Issue 2, 2016 · pp. 1–8 Read article
-
Review and Design of Voltage Sag Compensation Using Improved DVR System with Proportional Integral Controller
Abstract: The aim of this investigation is to remunerate voltage inthree-stage power systems during voltage sag conditions induced bybalanced and unsymmetrical deficiencies in power distributionsystems or offices in plants. Voltage plunges (also known as "voltagesags") are abrupt drops in voltage size. Their definition is usuallyanywhere between a couple of power-system recurrence trends and acouple of moments. The popularity of voltage plunges stemsprimarily from their effect on end-client hardware. Mechanicalprocesses can fail …
Published in Trends in Electrical Engineering · Vol. 11, Issue 1, 2021 · pp. 36–43 Read article