Search
89 articles for “ANOVA method”
-
The Effect of Magnesium and Zinc Lozenge on Postoperative Sequelae after Third Molar Surgery: A Prospective Randomized, Placebo-Controlled Study
Abstract: Background: The postoperative sequelae after third molar surgery include pain, swelling and trismus, Magnesium has antinociceptive effects that can prevent central sensitization caused by peripheral nociceptive stimulation by blocking the N-methyl-D-aspartate-type glutamate receptors, Zinc acts as anti-inflammatory agent, can promote wound healing, immune system modulation, tissue repair, and significant reduction in the use of analgesics for oral pain. This study was aimed to evaluate the efficacy of Magnesium and Zinc …
Published in Research and Reviews: A Journal of Dentistry · Vol. 12, Issue 2, 2021 · pp. 10–18 Read article
-
Investigating the Influence of Process Parameters on Photochemical Machining of Phosphor Bronze Alloy Microchannels
Abstract: Microchannels are widely employed in microfluidic devices, biomedical systems, and compact heat exchangers, where their functional efficiency depends strongly on surface finish, dimensional control, and edge quality. Traditional machining techniques often face limitations in producing such features with the required precision, prompting the use of advanced micromachining methods. In the present work, photochemical machining (PCM) has been applied to fabricate serpentine-shaped microchannels in phosphor bronze. The study systematically investigates the …
Published in Journal of Polymer & Composites · Vol. 14, Issue 2, 2026 · pp. 837–846 Read article
-
Tribological Performance and Wear Coefficient Prediction of AA2024–TiC Composites via Python-Based Machine Learning
Abstract: Determining wear coefficient accurately serves as a critical factor to maximize engineering materials' tribological characteristics. The experiment examines the wear characteristics of TiC-reinforced AA2024 aluminum alloy subjected to different tribological operating conditions. A pin-on-disc tribometer performed wear tests under different conditions of load and TiC weight fraction and sliding speed and duration. ANOVA statistical results show that load intensity and TiC reinforcement density stand out as principal variables that affect …
Published in Journal of Polymer & Composites · Vol. 13, Issue 6, 2025 · pp. 1099–1112 Read article
-
Information-Seeking Behaviour of B.Ed. Students in Indore Region College Libraries: An Empirical Study
Abstract: The study titled “Information Seeking Behaviour of Users in Bachelor of Education (B.Ed.) College Libraries of the Indore Region: A Study” examines how students, faculty members, and research scholars locate, access, and utilize information resources within B.Ed. college libraries. Using a mixed-method research design, data was collected from 535 respondents through standardized questionnaires—distributed in both physical and digital formats—and supported by informal interviews and personal observations for deeper qualitative insight. …
Published in OmniScience: A Multi-disciplinary Journal · Vol. 16, Issue 1, 2026 Read article
-
Design and Simulation of Forging Die Towards Improving Life of Closed Die
Abstract: Forging is the metal forming process which is used for forming complex shaped component withgeometrical accuracy. More than fifty percent of the forgings are processed through this way. Forgedcomponents required in many engineering sectors, most of them in the automotive sector. Themajority of the safety critical component and load bearing structural components are process throughit. By using forging process production of complex component is faster with less material waste. It …
Published in Journal of Production Research & Management · Vol. 11, Issue 1, 2021 · pp. 1–15 Read article
-
Experimental Investigation on Mechanical Characterization of Electrodeposited Shot Peened Copper Coated and Un-Coated Mild Steel
Abstract: The fatigue strength of fabricated copper coating on mild steel specimens under repeated loading and the overall number of cycles to failure has been investigated. The specimens of copper coating on mild steel substrate are fabricated by using an electro deposition shot peening method. The hardness behaviour of fabricated specimens studied and the experimental work has been carried out by using Vickers Micro Hardness under the load of 20N force. …
Published in Journal of Polymer & Composites · Vol. 13, Issue 3, 2025 · pp. 279–288 Read article
-
Comparative Evaluation of Fiber-Reinforced Composite and Elastic Fiber Posts in Reinforcing Peri-Cervical Dentin: an In-Vitro Study
Abstract: This study evaluates the fracture resistance of short-fiber reinforced composite and elastic fiber posts compared to conventional hybrid composites in reinforcing peri-cervical dentin of endodontically treated teeth. Methods: The crowns of thirty single-canal mandibular premolars were resected to achieve a dimension of 4mm from 1mm below the highest point of the proximal cervical line. In Group 1, teeth underwent endodontic treatment with gutta-percha filled up to the cement-enamel junction (CEJ) …
Published in Journal of Polymer & Composites · Vol. 13, Issue 3, 2025 · pp. 143–149 Read article
-
Exploring the Influence of Machining Parameters on Geometric Form and Orientation Controls (23 Design)
Abstract: This work explores the influence of machining parameters using on geometric form controls flatness and straightness as well as orientation control parallelism using an aluminum 6061 workpiece. Due to its good strength, machinability and cost- effectiveness, aluminum 6061 is widely used. In this experimental work, full factorial design is used and each factor has two levels. The response parameters chosen include flatness, straightness, and parallelism, which govern the form and …
Published in Journal of Experimental & Applied Mechanics · Vol. 16, Issue 1, 2025 · pp. 10–16 Read article
-
Investigation on Dry Sliding Wear Behaviour of AlSi7Mg0.3/B4C/ZrO2 Hybrid Composites using Taguchi Method
Abstract: Hybrid Aluminium/Boron carbide/Zirconium oxide (AlSi7Mg0.3/B4C/ZrO2) composites were fabricated utilizing stir casting technique by varying boron carbide content (4wt.%, 8wt.% and 12wt.%) and utilizing a fixed amount (4wt.%) of zirconium oxide particles. Optical microscopy revealed that B4C and ZrO2 particulates were dispersed uniformly in AlSi7Mg0.3 matrix. Dry sliding wear experiments were carried out utilizing the pin-on-disc tribometer with various levels of applied loads, sliding speeds and weight percentage of boron carbide …
Published in Journal of Polymer & Composites · Vol. 12, Issue 3, 2024 · pp. 166–177 Read article