33 articles for “Multilevel inverters”
-
Harmonics Analysis of Single Phase VSI with 5-level and 7-level Inverter
Abstract: Abstract: The conventional two-level inverter is most commonly used for AC drive systems. The inverter produces harmonics, which will cause heating of the power electronic devices as well as load and deteriorate the life of it. Thus, anyhow harmonics should be suppressed or removed, the most common or well-known method to filter out harmonics are introduction of various filters between inverter and load according to requirements. The filters are mainly …
Published in Recent Trends in Electronics Communication Systems · Vol. 6, Issue 1, 2019 · pp. 16–23 Read article
-
Improvement of Indirect Vector Control Induction Motor Drive Performance under Low Speed Operation using Five-Level Inverter
Abstract: The dynamic performance of vector controlled induction motor drive is poor and peak motor torque decreases under low speed operation. This reduction in torque is due to the non-linearity of voltage to frequency (Hz) during low frequency operation. The non-linearity is caused by stator voltage drop which in turn requires a larger percentage of overall terminal voltage. To overcome these problems multilevel inverter fed induction motor drive is presented in …
Published in Journal of Power Electronics and Power Systems · Vol. 3, Issue 2, 2013 · pp. 8–15 Read article
-
Enhancing Power Quality and Harmonics Control via Integration of PV, Wind, and Battery Systems with Three-level Inverter in DC Micro grid Management
Abstract: The primary goal of this research is to develop a multi-level inverter-based energy management approach for a smart DC-micro grid. An electric micro grid is created in this project by combining photovoltaic (PV), wind, and batteries. Solar and wind power can be efficiently extracted, and the quality of power can be improved by using FOPID control for source-side converters (SSC) and load-side converters controlled by multilevel inverters. To make the …
Published in Journal of Power Electronics and Power Systems · Vol. 14, Issue 1, 2024 · pp. 18–27 Read article
-
27- Level High Frequency Transformer Based- MLI for Integration of Renewable Energy
Abstract: This research proposes a unique high-frequency transformer (HFT)-based multilevel inverter(MLI) with 27 levels can be constructed with a single DCpower supply and twenty switching devices. The proposedMLI topology comprises three medium frequency isolationtransformers, each with a different rated voltage. Since thetransformers used in MLI operate at high frequencies, thesuggested system has a smaller volume and weight. Acascaded H-bridge (CHB) connects each transformer'sprimary windings, and the secondary windings areconnected in series …
Published in Journal of Power Electronics and Power Systems · Vol. 13, Issue 2, 2023 · pp. 1–11 Read article
-
Single-Phase Two-Stage Multi-Level Inverter Employing Low Number of Switching Devices
Abstract: In recent years, multilevel inverter (MLI) plays a significant role in low or medium voltage applications as a result of generating voltage with reduced harmonic contents. This paper proposes a new version of multi-level inverters (MLI) with reduced switching devices along with reduced harmonics content of output voltage, which results in low switching losses compared with conventional MLI topologies. In addition, the proposed inverter provides low total blocked voltage compared …
Published in Journal of Power Electronics and Power Systems · Vol. 9, Issue 2, 2019 · pp. 22–32 Read article
-
Comparison of Symmetrical and Asymmetrical Cascaded H-Bridge Inverter with Single DC Source
Abstract: This paper presents the comparison of traditional cascaded H-bridge inverter with isolated DC sources (symmetrical arrangement) and the proposed cascaded H-bridge inverter with single DC source (asymmetrical arrangement). Also, fundamental switching strategy is used to generate the control pulses. A conventional cascaded H-bridge (CHB) inverter requires ‘n’ numbers of DC sources for 2n + 1 levels. Without requiring transformers, the scheme proposed here allows the use of a single DC …
Published in Journal of Power Electronics and Power Systems · Vol. 2, Issue 1, 2012 · pp. 8–17 Read article
-
Closed Loop Control of Multi Level Inverter Tied with 415 V AC Source Using SV-PWM for Renewable Energy
Abstract: In this work, 415 V AC source is interfaced with three-level diode clamped inverter in which renewable energy source is used as a DC source, solar energy is used which is most popular renewable energy source. The obtained DC from the solar irradiation is fed to MPPT (Maximum Power Point Tracking) to utilize voltage at maximum power (DC). The perturb and observe technique is used in this work to track …
Published in Journal of Power Electronics and Power Systems · Vol. 6, Issue 1, 2016 · pp. 55–65 Read article
-
Novelty of Cascaded Inverter Based Two Stage Power Conditioning Systems for Constant Wind Power Applications
Abstract: Wind energy has proved to be the most promising renewable energy source because of its environmental friendly nature. Wind energy can be generated by harnessing the kinetic energy of atmospheric air. The present concern towards wind turbines is to increase the size of turbine in order to harvest more energy and also to reduce cost of per megawatt capacity. This paper proposes a 2-stage power conversion technique. The first stage …
Published in Journal of Power Electronics and Power Systems · Vol. 6, Issue 1, 2016 · pp. 1–11 Read article
-
The Electromagnetic Transients in Mixed Power Networks with Partial Undergrounding
Abstract: This paper deals with the electromagnetic transients in partially undergrounded mixed high voltage power networks. These networks can include several cable sections replacing parts of the overhead transmission lines. The analysis yields the transient voltage and current distributions along the normal and the partially undergrounded lines. Moreover, the results can indicate eventually existing localized voltage and current concentrations within the network. The study suggests an exact direct analytical distributed parameter …
Published in Journal of Power Electronics and Power Systems · Vol. 7, Issue 2, 2017 · pp. 1–13 Read article
-
Development of a Soft Computing-Based Island Detection System and Performance Analysis
Abstract: There has been an overestimation of the global energy consumption in the last few years. Distributed Generators are being propelled forward by the motivation provided by the absence of suitable transmission capacity, exaggerated transmission and distribution mishaps, and the release of power marketing (DGs). It's a distributed age unit (DG slash hack expansion) and regional units linked to distribution that power the system, which has yet to have hundreds of …
Published in Journal of Semiconductor Devices and Circuits · Vol. 8, Issue 3, 2021 · pp. 1–15 Read article
-
Improvement of Voltage Profile and Loss Reduction using Optimized Soft Computing Based Capacitor Placement Methodology
Abstract: Significant exploration has been done on the arrangement of ideal capacitor arranging in the appropriation frameworks for the assignments of power factor adjustment, voltage profile improvement and misfortune decrease. Particularly, mechanical plant with variable load conditions has huge inductive loads and its power factor is exceptionally poor. These ventures advantage most capacitor banks. This bank gives improved power factor, expanded voltage level on the load and lessen the electric service …
Published in Journal of Power Electronics and Power Systems · Vol. 10, Issue 2, 2020 · pp. 11–21 Read article
-
Mitigation of Harmonics in Industries using a Multilevel Shunt Active Power Filter
Abstract: The vast development in power electronic equipments causes higher harmonics in the distribution line in order to reduce the harmonics. This work proposes a design of Multi-Level Inverter (MLI) based Shunt Active Filter (SAF) intended to sort out the presence of harmonics in the distribution line. This proposed SAF utilizes three level diodes clamped MLI as VSI. d-q theory is employed for reference signal generation. In order to regulate the …
Published in Journal of Telecommunication, Switching Systems and Networks · Vol. 8, Issue 3, 2021 · pp. 39–50 Read article
-
Topology, Operation and Control of Modular Multilevel Converter for Grid Application: A Review
Abstract: Modular multilevel converter (MMC) is a widely accepted technology for high voltage direct-current (HVDC) application. Due to its modularity, scalability, power quality, and no need of bulky filter on ac side, they are widely used as voltage source converters in HVDC applications. This paper presents a comprehensive study on MMC technology for grid applications along with different modulation techniques and voltage balancing strategies which are essential for the converter to …
Published in Trends in Electrical Engineering · Vol. 7, Issue 1, 2017 · pp. 25–47 Read article