Search
11 articles for “double pipe heat exchanger”
-
Optimization of Procedure and Variables of a Double Pipe Composite Heat Exchanger with Protruding Surfaces
Abstract: Under low heat duty conditions, double pipe heat exchangers are employed. When utilized for heavy-duty tasks, they show limitations. To use double pipe heat exchangers for heavy-duty applications, heat transmission needs to be increased. In this project, we are investigating the optimization process parameters of a twin pipe heat exchanger with and without protruding surfaces. In both cases, the inner and outer tubes are composed of steel, and the working …
Published in Journal of Polymer & Composites · Vol. 13, Issue 3, 2025 · pp. 472–485 Read article
-
Passive Augmentation Studies in a Double Pipe Heat Exchanger with Ellipsoidal Dimples
Abstract: In this work, the numerical studies of heat transfer augmentation of a counter-current double pipe heat exchanger with ellipsoidal dimples (inward-facing, raised dimples) on the inner tube was performed using SOLIDWORKS software. The effect of dimple depth, dimple pitch and number of dimples/angles between two dimples on heat transfer was investigated at a constant volumetric flow rate of 4 LPM for hot (water) and cold (water) fluids. The effect of …
Published in Journal of Thermal Engineering and Applications · Vol. 13, Issue 2, 2026 Read article
-
Thermo-hydraulic Performance of Multi-Pass Double-Pipe Heat Exchangers: Integrating Polymer Composite Tube Wall Materials via CFD Parametric Study and Experimental Validation
Abstract: Metallic materials such as steel and copper have traditionally dominated heat exchanger manufacturing because of their excellent thermal conductivity, mechanical strength, and long-established industrial reliability. However, their high weight, susceptibility to corrosion in aggressive operating environments, and inability to provide tunable thermal properties have motivated interest in alternative materials for next-generation thermal systems. Thermally conductive polymer composites reinforced with graphene nanoplatelets (GNP), boron nitride (BN), and carbon-based fillers offer an …
Published in Journal of Polymer & Composites · Vol. 14, Issue 5, 2026 Read article
-
Thermal Augmentation in Refrigeration Systems Using Nano Fluid Assisted Double Pipe Heat Exchangers
Abstract: Improving thermal transport in refrigeration equipment plays a vital role in reducing energy usage and enhancing operational effectiveness. Among different exchanger arrangements, double-pipe heat exchangers are widely selected for applications involving high pressure and elevated temperature because of their compact structure and economical fabrication. Despite these advantages, thermal losses and limited heat transfer capability remain major concerns during operation. The present investigation focuses on the thermal behaviour of a Nano …
Published in Journal of Refrigeration, Air conditioning, Heating and ventilation · Vol. 13, Issue 2, 2026 · pp. 36–45 Read article
-
Thermo-hydraulic Performance of Annular-Finned Double-Pipe Heat Exchanger: Numerical and Experimental Investigation of Metallic and Polymer Composite Tube Wall Materials
Abstract: Double-pipe heat exchangers are central to the process industries — dependable, easily maintained, and straightforward to fabricate. Their conventional form relies on metallic tube materials, most often copper or stainless steel. Both metals conduct heat well, but they are dense, prone to corrosion in aggressive service environments, and increasingly at odds with the light-weighting goals that drive modern system design. Fibre-reinforced polymer composites, epoxy-based materials, and thermally enhanced thermoplastics such …
Published in Journal of Polymer & Composites · Vol. 14, Issue 3, 2026 · pp. 891–909 Read article
-
Experimental Investigation of Double Pipe Heat Exchanger to Improve Thermal Performance, By Using Cerium Oxide (CeO2) Nanofluid
Abstract: Heat exchanger is a device which is very important in every modern industry. Cerium Oxide is used as a nanofluid in this research paper which is made by mixing Cerium Oxide (CeO2) and water. The thermal performance analysis of double pipe heat exchanger is performed by changing the composition of Cerium Oxide nanofluid . At different flow rates (7, 8, 9 litres/min) of nanofluid, flow volume concentration (2%, 3%, 4%) …
Published in Recent Trends in Fluid Mechanics · Vol. 8, Issue 3, 2021 · pp. 24–31 Read article
-
Enhancing Efficiency and Adaptability of Double Pipe Heat Exchangers: Design and Implementation Perspectives
Abstract: The present study focuses on exploring the intricacies of twin pipe heat exchangers, highlighting their versatility and efficiency in various industrial applications. Twin pipe heat exchangers consist of concentric pipes through which fluids flow in opposite directions, enabling effective heat transfer across significant temperature gradients. This design is particularly advantageous in scenarios involving low flow rates or highly viscous fluids, as well as moderate heat loads. One of the key …
Published in Recent Trends in Fluid Mechanics · Vol. 12, Issue 1, 2025 · pp. 63–70 Read article
-
CFD Analysis: Double Pipe Heat Exchanger, Latent Heat Storage, and BIM-CFD Integration
Abstract: This is a review work covering four research papers. Heat exchangers transport thermal energy across fluids; research in SolidWorks 2014 compared flow simulation to the effectiveness-NTU approach. Slow PCM charging/discharging is a global concern in latent heat storage; research on the influence of flow rate and temperature on melting and solidification durations discovered efficiency in a triple tube heat exchanger design. Advances in computational fluid dynamics for forecasting separated flows …
Published in International Journal of Electrical Machine Analysis and Design · Vol. 2, Issue 2, 2024 · pp. 19–24 Read article
-
Comparison Study of Longitudinal Rectangular and Helical Fins in the Annulus Side of Double Pipe Heat Exchanger
Abstract: A comparison of experimental study is made between the enhancement of heat transfer in the horizontal double pipes with helical fins and longitudinal rectangular fins in the annulus side. The material is copper with inner tube internal diameter 10 mm, inner tube thickness 1 mm, outer tube external diameter 40 mm, outer tube thickness 1.5 mm, pitch length of 50, 75 and 100 mm, heat exchanger length 1100 mm for …
Published in Trends in Mechanical Engineering & Technology · Vol. 7, Issue 3, 2017 · pp. 29–35 Read article
-
Enhanced Heat Transfer in Double Pipe Heat Exchanger with Circular Fins Using Copper Nanofluid and Twisted Tape Inserts: A Computational Study
Abstract: The enhancement of convective heat transfer in a double-pipe heat exchanger utilizing circular finned twisted tape inserts and helical screw-tapes with centre rods, in conjunction with copper oxide nanofluid as the heat transfer medium was studied in this project. Computational Fluid Dynamics (CFD) simulations were conducted across Reynolds numbers ranging from 500 to 5000 to analyse heat transfer characteristics. The investigation focuses on Nusselt number improvement and friction factor analysis …
Published in Journal of Thermal Engineering and Applications · Vol. 12, Issue 1, 2025 · pp. 11–22 Read article
-
Thermo-Hydraulic Performance of a Double-Pipe Double-Pass Heat Exchanger using Annular Fins and Graphite-filled Epoxy Composite Tubes
Abstract: Double-pipe heat exchangers remain one of the most widely adopted thermal devices because of their simple construction, operational reliability, and ease of maintenance. Nevertheless, their performance is often constrained by the limited heat transfer area of smooth tubes and the long-term challenges associated with metallic materials, including corrosion, scaling, and structural weight. Recent advances in thermally conductive polymer composites provide an opportunity to overcome these limitations by replacing conventional metals …
Published in Journal of Polymer & Composites · Vol. 14, Issue 5, 2026 Read article