Search
9 articles for “direct evaporative cooling”
-
A Novel Approach in the Formulation of a Direct Contact Heat Exchanger
Abstract: Normal 0 false false false EN-US X-NONE X-NONE The paper is concerned with the development of a mathematical approach for a direct contact heat exchanger. An air washer has been considered for the analysis and a one dimensional model using mass and energy balance equation has been developed. The new solution presented for the model shows an excellent agreement with the literature available in the air conditioning. The effect on …
Published in Trends in Mechanical Engineering & Technology · Vol. 1, Issue 2-3, 2011 · pp. 1–8 Read article
-
Study of a Mist Enhanced Evaporative Cooler
Abstract: Comfort air conditioning through vapour-compression refrigeration is commonly used and is the energy-intensive system. That to split air conditioning system is being employed to create cooling in closed spaces which lag in fresh air supply leading to an increase in carbon dioxide concentration in the cooled space. This is of very much concern towards to maintain indoor air quality. Evaporative Cooling (or Desert Cooling) concept is also a known phenomenon …
Published in Journal of Refrigeration, Air conditioning, Heating and ventilation · Vol. 12, Issue 3, 2025 · pp. 1–13 Read article
-
Effect of Different Cooling Pad Materials on the Performance of the Evaporative Cooler
Abstract: Air conditioning (AC) becomes the most necessary appliance in homes and offices in every developed and developing country for achieving the required thermal comfort condition. But the literature reveals that the excessive use of AC creates physiological discomfort such as headache, alleging symptoms (fever, cold, itching) chest pain, etc. The above mention issues may be mitigated up to a certain level by using an evaporative cooler instead of ACs. The …
Published in Journal of Refrigeration, Air conditioning, Heating and ventilation · Vol. 10, Issue 3, 2023 · pp. 31–35 Read article
-
A Review on Modified Air Cooler with De-humidification
Abstract: The desert cooler is based on working principal of direct evaporative cooling system. So, when the desert cooler is used, air is cool with high humidity or moisture content, so because of that it is used only at dry places, and it is the big limitation of the desert cooler. To remove this limitation, we modified the working and structure of the air cooler. The modified air cooler works based …
Published in Trends in Mechanical Engineering & Technology · Vol. 8, Issue 1, 2018 · pp. 11–14 Read article
-
Study of Multistage LDAC System Aided Direct and Indirect Type of Dehumidifier with Solar Heating and Evaporative Cooling
Abstract: The aim of this paper is to study various studies done on multistage LDAC system. Some of the studies were based on a combination of multi-stage with VC systems to make it more effective. Some systems have an equal number of regenerator and dehumidifiers and some have only single regenerator between several dehumidifiers. Most of the systems have liquid desiccant type dehumidifiers but some use solid desiccant wheels for dehumidification. …
Published in Trends in Mechanical Engineering & Technology · Vol. 8, Issue 1, 2018 · pp. 15–20 Read article
-
Evaporative Cooling By Using Different Porous Materials
Abstract: The method of evaporative cooling involves raising the air temperature by causing water vapour in an airstream to evaporate. Waterneeds the latent heat of vaporisation to evaporate, and this heat is produced by ambient air and a drop in air temperature. A porousmedium is necessary for both direct and indirect evaporative cooling in order to allow heat and mass transfer between the medium'swater and the air moving through it, or …
Published in Journal of Refrigeration, Air conditioning, Heating and ventilation · Vol. 9, Issue 2, 2022 · pp. 29–37 Read article
-
Experimental investigation of humidification-dehumidification desalination system
Abstract: The aim of present study is to investigate an H-DH desalination system experimentally. The system consists of a solar air heater, a humidifier, and a dehumidifier connected with an evaporative cooler. The proposed system is operated in a closed loop configuration, at two airflow rates. The performance metrics are assessed via the examination of energy and economic factors. The solar air heater has the ability to produce hot air with …
Published in Journal of Polymer & Composites · Vol. 12, Issue 2, 2024 · pp. 104–113 Read article
-
Psychometric Analysis of an Induced Cooling Tower in a Humid Condition
Abstract: An Induced Cooling Tower (ICT) is an energy transformation device that facilitates heat and mass transfer by leveraging ambient conditions. ICTs are particularly effective in applications requiring a large heat transfer surface area, utilizing evaporative cooling of ambient air to cool hot steam. The performance of an ICT is significantly influenced by ambient humidity and temperature, making these environmental factors critical in its design and operation. As such, ICTs are …
Published in Journal of Thermal Engineering and Applications · Vol. 12, Issue 3, 2025 · pp. 22–29 Read article
-
Modification of Oscillating Mechanism of Table Fan for Throwing Air 360º
Abstract: Table fan is one of the common electric appliances used in houses, offices, shops and business establishments to provide air circulation which can greatly improve the atmosphere of any environment. Fan circulates the air, which enhances the evaporation rate of sweat from body, due to which body is cooled. There are many advantages of table fan compared to ceiling fan. Due to its portability, it can be used anywhere. The …
Published in Journal of Mechatronics and Automation · Vol. 3, Issue 1, 2016 · pp. 10–13 Read article