Search
11 articles for “Synchronous reference frame strategy”
-
Comparison of Control Strategies using Soft Computing Techniques for Shunt Active Power Filters in Aircraft Power Utility of 400 Hz
Abstract: Three different control strategies for extracting reference currents for shunt active power filters optimized using adaptive tabu search and genetic algorithm have been compared and their performance has been evaluated under different load conditions. The compensation ability of different control strategies will be compared and suggestion will be given for optimum strategy to be used under different loads. Simulation results using MATLAB have been included.Keywords: Active power filter (APF), constant …
Published in Journal of Aerospace Engineering & Technology · Vol. 4, Issue 1, 2014 · pp. 9–21 Read article
-
Performance Evaluation of Neural Network and Conventional Control Techniques Based Shunt Active Power Filter for Constant Frequency Aircraft Power System
Abstract: Synchronous reference frame strategy for extracting reference currents for shunt active power filters have been modified using artificial neural network and its performances have been compared. The acute analysis of comparison of the compensation capability based on THD and speed will be done, and recommendations will be given for the choice of technique to be used. The simulated results using MATLAB model are shown, and they will undoubtedly prove the …
Published in Journal of Aerospace Engineering & Technology · Vol. 6, Issue 1, 2016 · pp. 1–9 Read article
-
Comparison of Simulations Results of Fuzzy Logic, Neural Network and Conventional Scheme Based Controller for SAF in Constant Frequency Aircraft System
Abstract: SRF control strategy for finding reference currents for active power filters have been optimized using artificial neural network, fuzzy logic control and their performances have been evaluated. The acute analysis of comparison of the compensation capability based on THD and speedwell be done, and recommendations will be given for the choice of technique to be used. The simulated results using MATLAB model are shown, and they will undoubtedly prove the …
Published in Journal of Aerospace Engineering & Technology · Vol. 7, Issue 1, 2017 · pp. 1–9 Read article
-
Fuzzy Logic Controlled Shunt Active Power Filter for Constant Frequency Aircraft Power System in Balanced and Unbalanced Loads Conditions
Abstract: Synchronous reference frame technique for extracting reference currents for shunt active power filters has been assessed for 400 Hz aircraft electric power system. From that point forward, its performance has been compared when optimized using fuzzy logic control. Critical analysis of comparisons of the compensation ability of these two techniques based on THD and compensation time will be done, and suggestions will be given for the selection of the best …
Published in Journal of Aerospace Engineering & Technology · Vol. 5, Issue 2, 2015 · pp. 79–88 Read article
-
Comparative Critical Analysis of Control Techniques Optimized using ATS Algorithm and Conventional Control Techniques Applied in Shunt Active Power Filter for Total Harmonic Reduction for Power Electronic Converters in High Frequency (400 Hz) Aircraft Sys
Abstract: Three different conventional control strategies used for extracting reference currents for shunt active power filter and optimization of these strategies using Adaptive Tabu Search have been compared and their performances have been evaluated under different balanced and unbalanced loads connected together. The compensation ability of different control strategies will be compared, and suggestion will be given for optimum. Simulation results using MATLAB have been included. Keywords: Active powers filter (APF), …
Published in Journal of Aerospace Engineering & Technology · Vol. 5, Issue 3, 2015 · pp. 44–52 Read article
-
Simulation and Performance Based Comparison of Artificial Intelligence Based Shunt Active Power Filter in High Frequency Aircraft System for Power Quality Improvement
Abstract: Synchronous reference frame strategy for extracting reference currents for shunt active power filters have been optimized by using fuzzy logic control and adaptive tabu search algorithm respectively; their performances have been compared. The acute analysis of comparison of the compensation capability based on THD and speed will be done and recommendations will be given for the choice of technique to be used. The simulated results using MATLAB model are shown …
Published in Trends in Electrical Engineering · Vol. 6, Issue 1, 2016 · pp. 32–41 Read article
-
Performance Comparison of Control Approaches for Improving Power Quality by DSTATCOM
Abstract: Power quality is very important consideration for electrical supply system. A number of methods like active-passive filters, dynamic voltage restorer, distribution static compensator (DSTATCOM) etc; are used to compensate the power quality problems like harmonics, voltage sag and swell, load balancing and others. This paper presents performance comparison of two control strategies used for DSTATCOM to mitigate the problems of harmonics in distribution network. The DSTATCOM, a shunt connected device …
Published in Journal of Power Electronics and Power Systems · Vol. 6, Issue 1, 2016 · pp. 26–33 Read article
-
Voltage Sag and Swell Compensation Using DVR Based on Asymmetrical Cascade Multicell Converter
Abstract: Dynamic voltage restorer (DVR) is a device which is used to compensate the voltage sags and swells for the protection of sensitive loads. The compensation is done by use of a converter, in this paper DVR configuration is based on asymmetrical cascade multicell converter. One of the main advantages of asymmetrical cascade multicell is increase in the number of output voltage levels with reduced number of switches. 15 level asymmetrical …
Published in Journal of Microelectronics and Solid State Devices · Vol. 3, Issue 2, 2016 · pp. 23–26 Read article
-
ANN-Based Adaptive Rotor Current Control for DFIG Wind Systems: A Comparative Dynamic Analysis
Abstract: The variability of rotor current management in Doubly Fed Induction Generator (DFIG)-based wind energy conversion systems is crucial for maintaining stability in power extraction under fluctuating wind and grid circumstances. Traditional proportional-integral (PI) controllers, despite their ease of use, frequently exhibit diminished performance when faced with parameter uncertainty, nonlinear behaviors, and rapid wind fluctuations.This paper presents an adaptive rotor current control strategy, which is an Artificial Neural Network (ANN)-based approach …
Published in Journal of Power Electronics and Power Systems · Vol. 16, Issue 1, 2026 · pp. 41–53 Read article
-
Strengthening Low Voltage Ride-Through in Wind Energy Systems: A Comparative Study of DVR and STATCOM
Abstract: This study looks at the various methods used to improve the low-voltage ride-through (LVRT) capabilities of wind turbine systems (WT) that are based on double-fed induction generators (DFIG). The Type-III WT machine, which is mostly based on DFIG, is instantly connected to the grid without the digital power interface, making the terminal voltage or reactive electricity output unmanageable. This is because the world utilizes between 20% and 25% of renewable …
Published in Journal of Power Electronics and Power Systems · Vol. 14, Issue 3, 2024 · pp. 47–62 Read article
-
Power Quality Enhancement in Distribution System using D-STATCOM
Abstract: New solutions based on power electronics have been developed to safeguard commercial and industrial clients against power quality issues on the electrical distribution system, referred to as Custom Power Products. Custom power devices are classified into three categories by their structures such as dynamic voltage regulator (DVR), distribution static compensator (STATCOM) and unified power quality compensator (UPQC).The Distribution Static Compensator (D-STATCOM), one of the custom power product, is a shunt-connected …
Published in Recent Trends in Electronics Communication Systems · Vol. 8, Issue 2, 2021 · pp. 17–22 Read article