Search
11 articles for “Flat slab”
-
Comparative Study on Unsymmetrical G+15, G+20, G+25 Story Building with Flat Slab, Conventional Slab, And Flat Slab Without Drop
Abstract: There are different types of slabs from which the slab supported by column and beam is called as Conventional slab and the slab which is supported by Column and drop but the beam is not used in this slab is called as flat slab. Live and dead loads are transferred from slab to drop and then it is transfer to columns. This type of slab mostly preferred for long span …
Published in Journal of Structural Engineering and Management · Vol. 8, Issue 3, 2021 · pp. 15–27 Read article
-
Comparative Study on Unsymmetrical G+15, G+20, G+25 Story Building with Flat Slab, Conventional Slab, And Flat Slab Without Drop
Abstract: There are different types of slabs from which the slab supported by column and beam is called as Conventional slab and the slab which is supported by Column and drop but the beam is not used in this slab is called as flat slab. Live and dead loads are transferred from slab to drop and then it is transfer to columns. This type of slab mostly preferred for long span …
Published in Journal of Structural Engineering and Management Read article
-
Seismic Performance Evaluation for Flat Slabs under Different Types of Soil Condition by Response Spectrum Method
Abstract: The study investigates the seismic performance of various types of flat slabs under different soil conditions by response sepctrum method. The studied flat slab buildings are G+7 stroies special moment resisting frame—flat plate slab (Model 1), flat slab with peripheral beam (Model 2) and flat slab with drop panel (Model 3), whicharemodeled by ETABS v. 2016. The response spectrum analyses are performed according to BNBC 2017, considering seismic zone Dhaka …
Published in Recent Trends in Civil Engineering & Technology · Vol. 10, Issue 2, 2020 · pp. 23–29 Read article
-
Non-Linear Dynamic Analysis of High-Rise Flat Slab Structure with Various Lateral Load Resisting System: Indian Scenario
Abstract: In this technological era, the construction of high-rise flat slab structure is increasing everywhere, due to its major advantages over a conventional beam slab structure. Due to the poor performance of high-rise flat slab structure in higher seismic zones, IS 1893 (Part 1): 2016 discourages the use of flat slab structure in higher seismic zones. The use of high-rise flat slab structure in high seismic region is a risk, because …
Published in Journal of Structural Engineering and Management · Vol. 9, Issue 2, 2022 · pp. 1–12 Read article
-
Design of Flat Slab with MATLAB
Abstract: Flat slab is a reinforced concrete slab supported by columns with, or without drop. The columns may be with, or without column heads. Flat slab is a universal structural component widely used in construction nowadays. Flat slab requires minimum depth as compared to other slab, Hence, saving in material cost, speedy construction and it allows flexible column grids. MATLAB programming helps in high-performance numerical computation and perceptions. It provides an …
Published in Journal of Construction Engineering, Technology & Management · Vol. 6, Issue 2, 2016 · pp. 42–51 Read article
-
Comparative Study of Design Parameters of Flat Slab, Waffle Slab and Conventional Slab Using Etabs Software
Abstract: Different types of slab systems are conventional reinforced concrete slab which consist of beams and column for load transfer mechanism, Flat slab is that in which beams are not present and the slab is directly rested on the columns, and waffle slab is one in which the combination of deck and a system of equally spaced parallel ribs, having monolithic inter-section, that can be constructed in either orthogonal or skew …
Published in Journal of Structural Engineering and Management · Vol. 8, Issue 3, 2021 · pp. 7–14 Read article
-
Seismic Performance of Flat Slab Buildings Considering P-Delta Effect
Abstract: Flat slab structures are becoming quite popular due to functional and architectural advantages. The flat slab structures are flexible when compared to framed structures as the slab is directly columns. Typically the seismic forces in such a structure are resisted by shear wall systems. Under design seismic conditions the lateral displacements are large and the columns deform along with the lateral load resisting system. Under such conditions the columns are …
Published in Journal of Structural Engineering and Management · Vol. 7, Issue 1, 2020 · pp. 10–16 Read article
-
Comparative Study of Flat Slab and Conventional Slab Structure Based on Seismic Behaviour and Cost Effectiveness
Abstract: Flat slab recent earthquakes in which many concrete structures have been severely damaged or collapsed, have indicated the need for evaluating the seismic adequacy of buildings. About 60% of the land area of our country is susceptible to damaging levels of seismic hazard. We can’t avoid future earthquakes, but safe building construction practices can certainly reduce the extent of damage and loss. As being one of the special reinforced concrete …
Published in Journal of Construction Engineering, Technology & Management · Vol. 11, Issue 1, 2021 · pp. 45–49 Read article
-
A Comparative Study on Beam Slab and Flat Plate Building Frame under Seismic Load
Abstract: The study delves to evaluate the performance of beam slab and flat plate slab in the building frame due to seismic load. Two models of the same layout plan and story levels were compared under seismic load as per BNBC 2016—one was a typical frame structure with beam slab i.e., model 1 and another one was a frame structure with a flat slab, i.e., model 2. Frame structure with beam …
Published in Journal of Structural Engineering and Management · Vol. 8, Issue 1, 2021 · pp. 1–7 Read article
-
A Comparative Study on Beam Slab and Flat Plate Building Frame under Seismic Load
Abstract: The study delves to evaluate the performance of beam slab and flat plate slab in the building frame due to seismic load. Two models of the same layout plan and story levels were compared under seismic load as per BNBC 2016—one was a typical frame structure with beam slab i.e., model 1 and another one was a frame structure with a flat slab, i.e., model 2. Frame structure with beam …
Published in Journal of Structural Engineering and Management Read article
-
Cost Comparison of Post Tensioning, Prestressing and Conventional RCC Design
Abstract: The aim of project is to check the cost effectiveness of Post-Tensioning Slab with other design methods. For that purpose multipurpose hall is chosen with the footprint of 6 x 8 m having the total slab area is (768 sq. m). The analysis done by hand calculation and using the following methods: 1) Flat Plate (Without Drop and capital ) and Post-Tensioning Slab by using equivalent frame methods 2) Flat …
Published in Journal of Construction Engineering, Technology & Management · Vol. 5, Issue 2, 2015 · pp. 1–8 Read article