Research and Reviews: A Journal of Pharmaceutical Science

Active versus Passive Microbiological Air Sampling Risk Assessment: Relation and Comparative Study in Pharmaceutical Industry

  1. M.E. Eissa ✉
  2. A.M. Mahmoud
  3. A.S. Nouby

Abstract

Microbiological environmental monitoring of pharmaceutical manufacturing area is an essential task for control of the quality during medicinal dosage forms production. However, thorough scientific approach is critical to elucidate the full potential of microbiological test results and its significance. In the present study, 205 passive and 451 active air samples were withdrawn during course of ten months from air in class C production facility, dedicated for manufacturing of liquid and semisolid pharmaceuticals. Microbial counts of samples were enumerated and recorded then the results were trended and analyzed using commercial statistical software package. The outcome of data analysis showed that the general trend lines were shifted towards increasing of bioburden. For convenience, data were grouped into three main categories viz. passive air samples (PAS), active air samples (AAS) of manufacturing rooms and AAS for the main corridor and airlocks (AAScal). PAS bioburden counts were significantly lower than both AAS and AAScal which were not appreciably different from each other. However, they showed significant correlation between each other. Interestingly, there was significant linear relationship between AAS and both of PAS and AAScal which have pooled slope equals 0.72. Risk of failure for microbiological samples was higher for AAScal than AAS and AAS than PAS. The former was expected due to nature of the activity and the later because of the difference in the sensitivity. The currently applied analysis provided insight for quality monitoring and evaluation of bioburden in air of clean rooms in addition to rapid spotting of defects for immediate corrections.  Keywords: Environmental monitoring, pharmaceutical manufacturing, passive air, active air, out-of-controlCite this ArticleEissa ME, Mahmoud AM, Nouby AS. Active vs. Passive Microbiological Air Sampling Risk Assessment: Relation and Comparative Study in Pharmaceutical Industry. Research and Reviews:  A Journal  of Pharmaceutical  Science. 2016; 7(1): 13–27p.

Keywords

References (24)

  1. Baird R, Brown W, Shooter R. Pseudomonas Aeruginosa in Hospital Pharmacies. BMJ. 1976; 1(6008): 511–2p.
  2. Denyer SP, Baird RM . Guide to Microbiological Con trol in Pharmaceuticals and Medical Devi ces. 2nd Edn. Boca Raton: CRC Press; 2007.
  3. Napoli C. Prevention of Healthcare - Associated Infections: Which Sampling Method should be used to Evaluate Air Bio-Contamination in Operating Rooms? Epidemiol. 2013; 02(03): e106p. doi:10.4172/2161-1165.1000e106.
  4. Who.int. [Internet]. 2015 [Cited 13 Nov 2015]. Available from: http://www.who.int/immunization_standar ds/vaccine_quality/env_monitoring_cleanr ooms_final.pdf?ua=1
  5. Clontz L. Microbial Limit and Bioburden Tests: Validation Approach es and Global Requirements. 2nd Ed n. New York: CRC Press; 2008.
  6. Wan G, Chung F, Tang C. Long -Term Surveillance of Air Qu ality in Medical Center Operating Ro oms. Am J Infect Control. 2011; 39(4): 302–8p.
  7. Andersen B, Solheim N. Occlusive Scrub Suits in Operating Theaters during Cataract Surgery: Effect on Airborne Contamination. Infect Control Hosp Epidemiol. 2002; 23(4): 218–20p.
  8. Scaltriti S, Cencetti S, Rovesti S, et al . Risk Factors for Particulate and Microbial Contamination of Air in Operating Theatres. J Hosp Infect. 2007; 66(4): 320– 6p. Research & Reviews: A Journal of Pharmaceutical Science Volume 7, Issue 1 (online)7006-2229ISSN: 27Page . All Rights Reserved 6© STM Journals 201 27-13) 6(201 RRJoPS
  9. Tang C, Chung F, Lin M, et al. Impact of Patient Visiting Activit ies on Indoor Climate in a Medical Intensive Care Un it: A 1-Year Longitudinal Stud y. Am J Infect Control. 2009; 37(3): 183–8p.
  10. Bartlett K, Martinez M, Bert J. Modeling of Occupant-Generated CO2 Dynamics in Naturally Ventilated Classrooms. J Occup Environ Hyg. 2004; 1(3): 139–48p.
  11. Wan G, Chung F, Tang C. Long -term Surveillance of Air Qual ity in Medical Center Operating Roo ms. Am J Infe ct Control. 2011; 39(4): 302–8p.
  12. Tang C, Wan G. Air Quality Monitoring of the Post-Operative Recovery Room and Locations Surrounding Operating Theaters in a Medical Center in Taiwan. PLoS ONE. 2013; 8(4): e61093p.
  13. Ashour MS, Mansy MS, Eissa ME. Microbiological Environmental Monitoring in Pharmaceutical Facility. Egypt Acad J Bio Sci. 2011; 3(1): 63–74p.
  14. Eissa M, Seif M, Fares M. Assessment of Purified Water Qua lity in Pharmaceutical Facility using Six Sigma Tools. Int J Qual Assur. 2015; 6(2): 54–72p.
  15. USP 38 NF 33. United States Pharmacopeia 38/National Formulary 33 . Baltimore, MD, USA: 2015.
  16. Pasquarella C, Veronesi L, Napoli C, et al. Microbial Environmental Contamin ation in Italian Dental Clini cs: A Multicenter Study Yielding Recommenda tions for Standardized Sampling Metho ds and Threshold Value s. Sci Total Environ. 2012; 420: 289–299p.
  17. Napoli C, Marcotrigiano V, Montagna M. Air Sampling Procedu res to Evaluate Microbial Contamination: A Compariso n between Active and Passive Methods in Operating Theatres . BMC Public Health . 2012; 12(1): 594p.
  18. Whyte W. Sterility Assurance and Models for Assessing Airborne Bacterial Contamination. PDA J Pharm Sci Technol. 1986; 40(5): 188–97p.
  19. Orpianesi C, Cresci A, La Rosa F, et al . Evaluation of Microbial Contamination in a Hospital En vironment. Comparison between the Surface Air System and the Traditional Method. Nuovi Ann lg Microbiol. 1982; 34(3): 171–85p.
  20. Perdelli F, Sartini M, Orlando M, et al . Relationship between Settling Microbial Load and Suspended Microbial Lo ad in Operating Rooms. Ann lg: Medicina Preventiva e di Comunita. 1999; 12(5): 373–80p.
  21. ISO: Clean Rooms and Associated Controlled Enviro nments. Bioconta- mination Control. Part 1: General Principles and Methods. Milano: UNI; 2003; 14698–1p.
  22. Apps.who.int. [Internet]. 2015 [ Cited 13 Nov 2015]. Available from: http://apps.who.int/prequal/trainingresourc es/pq_pres/workshop_China_November20 09/english/3-2_Microbiological Quality Control.ppt.
  23. Wilkinson I. [Internet]. 2015 [ Cited 14 Nov 2015]. Available from: https://www.acipc.org.au/PDFs/2013prese ntations/Tuesday/Irene%20Wilkinson.pdf
  24. Dharan S, Pittet D. Environmental Controls in Operating Thea tres. J Hosp Infect. 2002; 51(2): 79–84p. Cite this Article Eissa ME, Mahmoud AM, Nouby AS. Active vs. Passive Microbiological Air Sampling Risk Assessment: Relation and Comparative Study in Pharmaceutical Industry. Research and Reviews: A Journal of Pharmaceutical Science. 2016; 7(1): 13–27p.