Research & Reviews : Journal of Physics

Transient Stability Comparison for an Integrated Power System Using Statcom and SVC

  1. Sandeep Sharma ✉
  2. Anubhav Choudhary
  3. Pankaj Kumar
  4. Eakansh Gupta

Abstract

Transient stability control plays a significant role in maintaining the stable operation of power systems in case of large disturbances and faults. This paper compares the role of Static Synchronous Compensator (STATCOM) and Static Var Compensator (SVC) in mitigating the fault and establishing transient stability in a 9 MW integrated wind farm power plant. SVC and STATCOM are FACTS (Flexible Alternating Current Transmission System) devices used for efficient power flow and fault compensation. The comparison is based on different criteria like real and reactive power compensation and stability during transient time. Response times of both the devices are taken into consideration. Simulations are carried out in MATLAB/Simulink environment for the integrated wind farm phasor model. The simulation results provide an insight into effectiveness and robustness of the STATCOM and SVC on transient stability improvement of the system. Keywords: Transient stability, FACTS, STATCOM, SVC, Induction Generator, Wind Farm, MATLAB/SIMUL INK Cite this ArticleSandeep Sharma, Anubhav Choudhary, Pankaj Kumar, Eakansh Gupta. Transient Stability Comparison for an Integrated Power System Using Statcom and SVC. Research & Reviews: Journal of Physics. 2019; 8(2): 112–116p.

References (6)

  1. Sravanthi P, Rani KR, Amarnath J, et al. Critical Clearing Ti me and Transient Stability Ana lysis of SCIG Based Wind Farm with STATCOM. 2014 International Conference on Smart Electric Grid (ISEG), Guntur. 2014; 1–8p. Research & Reviews: Journal of Physics Volume 8, Issue 2 ISSN: 2278-2265 (Online), ISSN: 2347-9973 (Print) RRJoPHY (2019) 112-116 © STM Journals 2019. All Rights Reserved Page 116
  2. Sabrine L, Othman H. Wind Generator Stability by Using STATCOM. 2014 5th International Renewable Energy Congress (IREC), Hammamet. 2014; 1–6p.
  3. Kailasa Gounder Y, Nanjundappan D, Boominathan V. Enhancement of Transient Stability of Distribution System with SCIG and D FIG Based Wind Farms Using STATCOM . IET Renew Power Gener. 2016; 10(8): 1171–1180p.
  4. Zhou H, Wei H, Qiu X, et al. Improvement of Transient Voltage Stability of the Wind Farm Using SVC and TCSC . 2011 Asia-Pacific Power and Energy Engineering Conference , Wuhan. 2011; 1–4p.
  5. Yanjuan W, Linchuan L, Fang Z. Installation SVC to Improve Output Active Po wer of Large-Scale Wind Farm Based on the Transient Sta bility. 2012 Power Engineering and Automation Conference, Wuhan. 2012; 1–3p.
  6. Grünbaum R. FACTS for Grid Integration of Wind Pow er. 2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe) , Gothenburg. 2010; 1–8p. Cite this Article Sandeep Sharma , Anubhav Choudhary , Pankaj Kumar , Eakansh Gupta . Transient Stability Comparison for an Inte grated Power System Using Statcom and SVC . Research & Reviews: Journal of Physics . 2019; 8(2): 112–116p.

Read more of it

Subscribe to one journal or build your own list of several. One invoice, one payment, access for a full year.

Subscribe to journals →

Publish your article

Peer-reviewed journals across every subject, with open access options. Send your manuscript to the right editor today.

Publish with us → Calculate your APC
Support