Journal of Instrumentation Technology & Innovations

Pulse Oximeter using PSoC

  1. Sanjeetha Sara John ✉
  2. Anantha Christhu Raj

Abstract

A pulse oximeter to measure the oxygen saturation in blood as well as heart rate was developed using PSoC. The method proposed here is to transmit light of two different wavelengths through the finger and tissues and to measure the change in absorption intensities. The signals are obtained as photoplethysmograph (PPG) waveforms. The pulse oximeter finds the variations in both the waveforms and calculates the SpO2 and heart rate of an individual. The system developed has a wide clinical application and can be used for patient monitoring and for doing vascular assessment.  It also helps us to explore the use of SOC in medical care devices. An adult SpO2 finger probe nellcor DS100A sensor was used for this project.

Keywords

References (10)

  1. Anan Wongjan, Prasit Julsereewong , Continuous Measurements of ECG and SpO2 for Cardiology Information System , Proceedings of the IMEC , March 18 –20, 2009; 2, 978–81p.
  2. Sangeeta Bagha, Laxmi Shaw, A Real Time Analysis of PPG Signal For Measurement of SpO2 and Pulse Rate, International Journal of Computer Applications December 2011; 36,11: 45p.
  3. Yitzhak Mendelson. Pulse Oximetery: Theory and Application for Noninvasive Monitoring, Clinical Chemistry June 1992; 38, 9: 1601–1609p.
  4. Cristian R otariu, Vasile Manta,Wireless System for Remote Monitoring of Oxygen Saturation and Heart Rate, Federated Conference on Computer Science and Information Systems, 2012; 215–218p.
  5. D.J.R.Kiran Kumar, Nalini Kotnana, Design and Implementation of Portable Health Monitoring Sy stem using PSoC Mixed Signal Array Chip, International Journal of Recent Technology and Engineering (IJRTE) August 2012; 1, 3: 59–65p.
  6. Eun Geun, Hyun Heo, Measurement Site and Applied Pressure Consideration in Wrist Photoplethysmography , 23 rd International Conference on Circuits and Systems, Computer and Communications 2009; 1129–32p.
  7. Jaco Schoevers, Cornie Scheffer, Ricky Dippenaar, Low Oxygen Saturation Quantification in Human Arterial and Venous Circulation, IEEE Transactions on Biomedical Engineering March 2009; 11, 3: 846–854p.
  8. P Kyriacou, S Powell, R Langford, Jones, Investigation of Oesophageal Photoplethysmographic Signals and Blood Oxygen Saturation Measurements in Cardiothoracic Surgery, Physiological Measurement 2002; 23, 533–545p.
  9. Roberto Marani, Gennaro Gelao, Anna Gina Perri, Design and Prototyping of a Miniaturized Sensor for Non -Invasive Monitoring of Oxygen Saturation in Blood, International Journal of Advances in Engineering & Technology Jan 2012; 2,1: 19–26p.
  10. Y. Mendelson, R. J. Duc kworth, A Wearable Reflectance Pulse Oximeter for Remote Physiological Monitoring, Proceedings of 28th IEEE Annual International Conference New York , Aug 30–Sept 3 2006; 912–915p.