International Journal of Algorithms Design and Analysis Review Review Article
Human Deep Skin Surface Vibration Frequency Detection from CT and DT Signals Using Genetic Algorithms
Abstract
To diagnose respiratory problems early on, a contactless, non-invasive, real-time assessment of human vibration is a crucial prerequisite. Optoelectronic plethysmography (OEP) and the forced oscillation technique (FOT), are two widely utilized methodologies, depending on variations in each patient’s local chest impedance. Calibration of the devices before each measurement is hence the primary problem of these approaches. This report presents a simulation-based analysis to assess the effectiveness of the CT and DT Signals as a substitute. The study’s conclusion suggested that the self-mixing-based optical feedback interferometry (SM-OFI) might be employed as a vibration measurement tool. The outcomes also show that CT and DT Signals can detect heart activity. One of the main goals of clinical research and science is to determine vibration perception thresholds (VPT) to evaluate human somatosensory capabilities. Seldom has the reaction of several mechanoreceptors to a growing contact force been investigated. We hypothesize that the VPTs of fast-adapting mechanoreceptors in the human foot sole drop as contact force increases. Using a vibration exciter, the VPTs of ten healthy volunteers were recorded at 30 Hz and 200 Hz at the right foot’s heel. An integrated force sensor allowed for the exact adjustment of contact forces within the range of 0.3 N to 9.6 N. Contact force and frequency were found to have significant major effects. Additionally, a significant relationship was seen between frequency and contact force, indicating that an increase in contact force had an impact. We assume that the Meissner and Pacinian corpuscles follow the same rules for contrast enhancement and spatial summation, respectively. Because Pacinian corpuscles are located in the periosteum or interosseous membrane, we assume that they have an impact on them in addition to spatial summation.
Keywords
References (12)
- Trupthi M, CH NC, SNEHA S, Prasad MH, K MS. LCDDF: An Adaptive and Learning based Framework with Feature Selection for Efficient Detection of Concept Drift in Data Streams. 2024. doi:10.21203/rs.3.rs-3893993/v1
- Rovati L, Cattini S, Palanisamy N. Measurement of the fluid-velocity profile using a self-mixing superluminescent diode. Measurement Science and Technology. 2011;22(2):025402. doi:10.1088/0957-0233/22/2/025402
- Milesi I, Norgia M, Pompilio PP, Svelto C, Dellaca RL. Measurement of Local Chest Wall Displacement by a Custom Self-Mixing Laser Interferometer. IEEE Transactions on Instrumentation and Measurement. 2011;60(8):2894-2901. doi:10.1109/tim.2011.2118830
- Prashanthi J, Santhoshi TS, Goud KR, Chary N. IoT security protocols for multimodal biometric system-based identification of individual vault access. Int J Comput Tech. 2024;11(1):159–162.
- Bhushan PV, Chary CN, Nithesh V, Singh An efficient system for heart risk detection using associative classification and genetic algorithms. Int J Comput Tech. 2017 Nov-Dec;4(6):131–139.
- Bhushan PV, Nitesh V, Chary CN, Gupta KG. Novel approach for multi-cancers prediction system using various data mining techniques. Int JManag Technol Eng. 2018 Aug;8(VIII):1629–1640.
- Li J, Niu H, Niu Y. Laser feedback interferometry and applications: a review. Optical Engineering. 2017;56(5):050901. doi:10.1117/1.oe.56.5.050901
- Ramírez-Miquet EE, Perchoux J, Da Costa Moreira R, Luna-Arriaga A, Zhaoa Y, Tronche C, Sotolongo-Costa Optical feedback interferometry: from basics to applications of laser flowmetry. Rev Cuba Fis. 2017;34:48-57.
- Gupta G, Narasimha Chary C, Krishna A. Study on health care life log by the level of care required using keygraph technology in text data mining. J Innov Dev Pharm Tech Sci. 2018;1(1):22–27.
- Haupt RL, Haupt Practical genetic algorithms. 2nd ed. Hoboken, NJ, USA: John Wiley & Sons, Inc.; 2003.
- Stetson KA. Method of vibration measurements in heterodyne interferometry. Optics Letters. 1982;7(5):233. doi:10.1364/ol.7.000233
- Yuan H, Poeggel S, Newe T, Lewis E, Viphavakit C, Leen G. An Experimental Study of the Effects of External Physiological Parameters on the Photoplethysmography Signals in the Context of Local Blood Pressure (Hydrostatic Pressure Changes). Sensors. 2017;17(3):556. doi:10.3390/s17030556