Experimental Evaluation of Environmental Friendly and Low Global Warming Refrigerants as an Alternative Option for Window Air Conditioning SystemBy B. Hadya, P. Usha Sri
Abstract: This paper presents an experimental evaluation and performance comparison of window air-conditioning system with R-410A and R32 and to compare with HCFC-22 refrigerant. The base line test is performed with 2 “Ton of Refrigeration” (TR) capacities air conditioner, with evaporator temperature of 7.2 °C and condenser temperature of 54.4 °C. The coefficient of performance (COP) of the refrigerants R32, R22 and R410A are 3.81, 3.15 and 2.17 respectively simulated; it …
Published in Journal of Refrigeration, Air conditioning, Heating and ventilation · Vol. 1, Issue 3, 2014 · pp. 7–13 Read article →