DESIGN OF POST-TENSIONED SLAB & ITS BEHAVIOUR WITH OPENING
Abstract: We live in a fast-paced world where every aspect of life has evolved. In this technological era, the need for change is constant. Many consumer goods have been adapted to fit the new circumstances.. Post Tensioned slabs are the evolution in the field of design which got enhanced due to need of today’s world and in this requirement of architect or customers are also increased by creating opening in slabs …
Published in Recent Trends in Civil Engineering & Technology · Vol. 14, Issue 2, 2024 · pp. 1–9 Read article
-
A Comparative Study on Beam Slab and Flat Plate Building Frame under Seismic Load
Abstract: The study delves to evaluate the performance of beam slab and flat plate slab in the building frame due to seismic load. Two models of the same layout plan and story levels were compared under seismic load as per BNBC 2016—one was a typical frame structure with beam slab i.e., model 1 and another one was a frame structure with a flat slab, i.e., model 2. Frame structure with beam …
Published in Journal of Structural Engineering and Management · Vol. 8, Issue 4, 2021 · pp. 1–7 Read article
-
Comparative Study of Design Parameters of Flat Slab, Waffle Slab and Conventional Slab Using Etabs Software
Abstract: Different types of slab systems are conventional reinforced concrete slab which consist of beams and column for load transfer mechanism, Flat slab is that in which beams are not present and the slab is directly rested on the columns, and waffle slab is one in which the combination of deck and a system of equally spaced parallel ribs, having monolithic inter-section, that can be constructed in either orthogonal or skew …
Published in Journal of Structural Engineering and Management · Vol. 8, Issue 3, 2021 · pp. 7–14 Read article
-
A Comparative Study on Beam Slab and Flat Plate Building Frame under Seismic Load
Abstract: The study delves to evaluate the performance of beam slab and flat plate slab in the building frame due to seismic load. Two models of the same layout plan and story levels were compared under seismic load as per BNBC 2016—one was a typical frame structure with beam slab i.e., model 1 and another one was a frame structure with a flat slab, i.e., model 2. Frame structure with beam …
Published in Journal of Structural Engineering and Management · Vol. 8, Issue 1, 2021 · pp. 1–7 Read article
-
Comparative Study of Seismic Performance of Conventional Tube Structures and Diagrid Structure
Abstract: AbstractConstruction of tall building is rapidly increasing throughout the world. Advances in construction technology, structural systems, analysis and design software facilitated the growth of the buildings. Recently, the diagrid structural system has been widely used for tall buildings due to the structural efficiency and aesthetic potential provided by the unique geometric configuration of the system. The “diagrid” is a combination of the two words i.e. diagonal and grid which form …
Published in Journal of Structural Engineering and Management · Vol. 5, Issue 1, 2018 · pp. 32–38 Read article