storey drift
7 articles · search the full text for this term
-
Performance Based Seismic Evaluation of G+12 RCC Structures in Seismic Zone IV with and without Corner Shear Walls Considering Soil Types I, II, and III
Abstract: Seismic behavior of multi-storey buildings is significantly influenced by structural stiffness and supporting soil conditions. This study investigates the seismic response of a G+12 reinforced concrete building by comparing two structural configurations, namely buildings with shear walls and buildings without shear walls, under three soil conditions: Type I, Type II, and Type III soils. The analysis is carried out using the response spectrum method in accordance with IS 1893 (Part …
Published in Recent Trends in Civil Engineering & Technology · Vol. 16, Issue 2, 2026 · pp. 1–14 Read article
-
Review On BIM-Based (Revit+Robot Software) Comparative Wind Load Analysis of High-Rise RCC Buildings in Zone-III, IV and V
Abstract: Wind load is one of the most critical factors influencing the design and serviceability of high-rise reinforced concrete (RCC) buildings. As building height increases, wind-induced effects such as storey drift, lateral displacement, and structural stiffness become dominant design considerations. Numerous studies have been conducted using conventional and advanced techniques such as Finite Element Method (FEM), Computational Fluid Dynamics (CFD), and Building Information Modelling (BIM). However, limited research focuses on comparative …
Published in Journal of Structural Engineering and Management · Vol. 13, Issue 2, 2026 · pp. 27–41 Read article
-
Evaluating Diagrid Systems: A Modern Approach to Lateral Load Resistance Across Varied Building Heights
Abstract: Modern architectural design and engineering often incorporate advanced structural systems, with diagrid structures becoming popular for high-rise buildings due to their unique geometric patterns and aesthetic appeal. Despite considerable global research on diagrids, a detailed comparative analysis of their structural efficiency remains limited. This thesis assesses the structural efficiency and seismic performance of diagrid lateral load-resisting systems. The effectiveness of diagrids was compared to conventional building designs in multi-storey buildings …
Published in Journal of Structural Engineering and Management · Vol. 11, Issue 3, 2024 · pp. 1–12 Read article
-
Wind’s Influence on Tall Buildings with Different Aspect Ratios
Abstract: Skyscrapers and other large buildings are being constructed worldwide these days. Because wind is so dynamic, it plays a major part in the design of these towering structures. The placement and height of such structures have a major impact on how wind affects them. The comparable static approach is used in this work to evaluate wind loads on structures with variable aspect ratios attained by altering the number of bays. …
Published in Journal of Offshore Structure and Technology · Vol. 11, Issue 2, 2024 · pp. 34–43 Read article
-
Exploring Diagrid Efficiency: A Modern Analysis of Lateral Load Resistance Across Building Heights
Abstract: Modern architectural design and engineering often feature innovative structural systems, with diagrid structures standing out as an aesthetically appealing solution for tall buildings due to their geometrically complex patterns. Despite extensive global research on diagrids, a comprehensive study systematically comparing their structural efficiency is still lacking. The structural efficiency and seismic performance of diagrid lateral load-resisting systems were evaluated in this thesis. The study compared the diagrid system's effectiveness against …
Published in Journal of Construction Engineering, Technology & Management · Vol. 14, Issue 2, 2024 · pp. 11–23 Read article
-
Seismic Analysis of G+10 Building With and Without Zipper Brace Frame
Abstract: This paper presents a seismic analysis of a G+10 building with and without Zipper Brace Frame (ZBF). The research begins with a detailed literature review, investigating the existing seismic-resistant techniques employed in high-rise buildings. The Zipper Brace Frame is introduced as an innovative system that has shown promising results in enhancing seismic performance while maintaining architectural aesthetics. Two analytical models are created: one without bracing systems and the other incorporating …
Published in Journal of Structural Engineering and Management · Vol. 10, Issue 3, 2023 · pp. 27–34 Read article
-
A Comparative Evaluation of a 13-story G+ Building with a Soft Storey, Using Pushover Analysis, with a Focus on the Impact of Different Placement of Shear Walls
Abstract: Asymmetrical structures with varying degrees of irregularity have proven to be a significant factor in causing collapses, damage to property, and injury during earthquakes. Despite extensive research on asymmetric buildings, there are currently no established guidelines for multi-story structures of this type. A soft storey, also known as a weak storey, is a level in a structure with insufficient rigidity or ductility to sustain earthquake-induced damage Pushover analysis has been …
Published in Recent Trends in Civil Engineering & Technology · Vol. 12, Issue 3, 2022 · pp. 1–9 Read article