Search
290 articles for “SEI”
-
Flexibility Analysis of Refinery Piping System
Abstract: Piping systems in downstream refineries and process plants experience a great thermal strain due to the difference between ambient and operating temperatures of process and utility fluid flowing through them. This thermal growth causes thermal stresses which leads to failure in piping components like flange leakage, deflection in piping, fractures at nozzle juncture and other fatal errors in piping system. Therefore, these piping structures must be flexible enough to support …
Published in Journal of Petroleum Engineering & Technology · Vol. 5, Issue 2, 2015 · pp. 53–59 Read article
-
Solutions to Problems Faced in Well Log Analysis in fractured metamorphic Reservoir Systems Due To Multiple Porosities and Lithology’s
Abstract: Metamorphic rocks are the most bottomless non-terrigenous sedimentary rock and are made essentially out of transformative minerals. Most metamorphic rocks shape from calcareous stores that collect in marine conditions running from salt marshes to reefs to profound sea bowls. Unmistakable and one of a kind parts of transformative rocks are their dominatingly intrabasinal starting point, their essential reliance on natural exercises for their constituents and their powerlessness to change by …
Published in Journal of Petroleum Engineering & Technology · Vol. 9, Issue 1, 2019 · pp. 36–42 Read article
-
EFFECT OF RE-ENTRANT CORNER IRREGULARITY IN A STRUCTURE
Abstract: AbstractIrregularities are not avoidable in construction of a building. Building Structures are almost irregular, as ideal perfect regularity very rarely occurs now days. As far as buildings structures are concerned , for practical use , Indian seismic code divides irregularity in structure which are in plan irregularity and in elevation irregularity, but it had been found and realized that irregularity in structures is the result of a combination of both …
Published in Journal of Structural Engineering and Management · Vol. 4, Issue 3, 2017 · pp. 31–37 Read article
-
Strength Evaluation of Uniaxial Loaded Rectangular Confined RC Column under Static Load
Abstract: AbstractIS 456:2000 provides the guideline for RC column design and IS 13920:2016 provides the guideline for ductile design and detailing of RC columns to be provided in buildings to be constructed in seismic zones. The confining steel is provided to achieve the desired ductility in RC columns. The constitutive law under monotonic axial compression is proposed by researchers for confined concrete. It gives larger stress and strain values compared to …
Published in Journal of Structural Engineering and Management · Vol. 4, Issue 3, 2017 · pp. 7–12 Read article
-
Octagrid an Alternative Lateral Load Resisting System
Abstract: The cost of the land in the rapidly developing urban cities have skyrocketed in the last few decades. Acquiring a piece of land has become very difficult for the builders and developers for different amenities and hence the concept of tall buildings has spread its roots in the urban infrastructure scenario. Tall buildings facilitate the optimum use of land and many amenities such as offices, residential apartments, shopping malls and …
Published in Journal of Structural Engineering and Management · Vol. 7, Issue 3, 2020 · pp. 29–33 Read article
-
Analysis of RC Frames Using Different Bracing Systems in Different Positions and Zones
Abstract: Structures are mainly built to enhance the performance of several activities like recreation, transportation, power generation, etc. They are built to sustain the loads coming on them during their service life by carrying adequate strength and also limit the deformation by possessing enough stiffness. Strength of a structure depends mainly upon the characteristics of material with which it is constructed. Stiffness is dependent upon the cross-sectional and geometrical properties of …
Published in Journal of Structural Engineering and Management · Vol. 3, Issue 1, 2016 · pp. 16–27 Read article
-
Comparative Study of Multistorey Building with Composite Column at Soft Storey
Abstract: Increase in population, car parking space is major concern. Hence, trend has been set up to use ground floor for parking purpose. Literature shows that, large number of reinforced concrete (RC) building with soft storey damaged by earthquake shaking due to many structural deficiencies such as, column with insufficient confinements, strong beam weak column, formation of plastic hinge at beam-column joint, opening of 90 degree ties, poor detailing in beam-column …
Published in Journal of Structural Engineering and Management · Vol. 3, Issue 2, 2016 · pp. 37–42 Read article
-
Design of Steel Plate Shear Wall with Opening for Steel Building
Abstract: Steel plate shear walls have been used more and more in the steelstructures to resist earthquake and wind forces. This system offersseveral advantages as compared to the other usual lateral load resistingsystems. Steel saving, speed of erection, reduced foundation cost, and increased usable space in buildings are some apparent advantages ofthe steel plate shear walls. Steel plate shear walls also provide majorstiffness against building drift for the hi-rise buildings.This paper …
Published in Journal of Structural Engineering and Management · Vol. 1, Issue 3, 2014 · pp. 23–30 Read article
-
Comparative Analysis of Structure Subjected to Blast Loading
Abstract: Structures are constantly evolving with regard to the safety and usability criteria. The structures are expected to provide safe shelter for the dwellers by providing economy and value at the same time. As we progress further into the twenty-first century, engineers are presented with modern problems that their predecessors were almost none accustomed to. Blast loads on the structures were one of such loads that the engineers in the past …
Published in Journal of Structural Engineering and Management · Vol. 8, Issue 1, 2021 · pp. 8–14 Read article
-
Comparative Study on Unsymmetrical G+15, G+20, G+25 Story Building with Flat Slab, Conventional Slab, And Flat Slab Without Drop
Abstract: There are different types of slabs from which the slab supported by column and beam is called as Conventional slab and the slab which is supported by Column and drop but the beam is not used in this slab is called as flat slab. Live and dead loads are transferred from slab to drop and then it is transfer to columns. This type of slab mostly preferred for long span …
Published in Journal of Structural Engineering and Management · Vol. 8, Issue 3, 2021 · pp. 15–27 Read article
-
Literature Review on Structural Role of Diagrids in High-Rise Structure under dynamic forces
Abstract: Abstract – The Present literature Review focus on the response of high-rise structure using diagrids structural elements, various research work is conducted on diagrids by making variation in diagrids shape, Angle of Inclination, Location, and geometric properties. The main aim of this Literature review is to find suitable research gap on topic related to diagrids. This review paper summarizes various research work achieved by diagrid structural system for high rise …
Published in Journal of Structural Engineering and Management · Vol. 9, Issue 1, 2022 · pp. 10–16 Read article
-
Comparative analysis of with and without P-∆ effect on plan irregular RC structure with different positions of shear wall
Abstract: P-∆ effect is the second order analysis method which is cause due to wind or seismic effect. This secondary effect causes the geometric non-linearity in structure. For high rise structure the P-∆ effect plays the significant role on the building stability because in lots of cases it has been found that failure of tall building is a function of slenderness of building members and second order effect. In P-∆ analysis, …
Published in Journal of Structural Engineering and Management · Vol. 9, Issue 2, 2022 · pp. 24–32 Read article
-
Comparison of Conventional RCC Columns, Steel Columns and Composite Columns
Abstract: Worldwide, the steel industry is expanding almost everywhere. Compared to the USA, EU, and other developed nations, India uses less steel in the construction industry. Additionally, India's cities have some of the highest population densities per square kilometre, which limits horizontal construction growth and favours vertical development. Steel structures are more ductility and can undergo more deflections while concrete structures are larger and attracts more seismic weight. Hybrid construction combines …
Published in Journal of Structural Engineering and Management · Vol. 10, Issue 3, 2023 · pp. 35–44 Read article
-
Influence of Sediment Yield Over Life of Reservoir using Arc SWAT, to Adjudge Useful Life of Reservoir by Anova Analysis for Sri Ram Sagar Project
Abstract: Certain issues that include stresses, floods, seismic loads could be observed inevitable andunpredictable in terms of occurrence, ultimately affect the functionality and life span for anyReservoir. Another important factor, which ultimately and strappingly influences any robustReservoir and its storage capacity is Sedimentation. Appraisal of quantity of sediment and applicationof proper remedial measures could significantly sustain and enhance the storage capacity of thereservoir. This study primarily deals on evaluating the annual …
Published in Journal of Water Resource Engineering and Management · Vol. 8, Issue 1, 2021 · pp. 17–26 Read article
-
REVIEW PAPER ON SIESMIC ANALYSIS OF MULTISTOREY BUILDING WITH FLOATING COLUMN
Abstract: Recent construction practices have seen a tremendous use of first few floors as parking spaces ,banquet halls, auditoriums and community halls, etc. All these amenities require large unobstructed spaces and the normal column arrangement poses interruption. this problem is dealt with the use of floating columns. Floating column is a column that does not continue till the foundation level but rests on a beam.due to this feature the load transfer …
Published in Recent Trends in Civil Engineering & Technology · Vol. 9, Issue 2, 2019 · pp. 11–13 Read article
-
Analysis of Multistoried RCC Building with Dampers as Energy Dissipation System using ETABS
Abstract: In order to have earthquake resistant structures, fluid viscous dampers have been used.In present study G+7 Story buildings is compared with the seismic effect of structure with dampers and without dampers. In the present study the software ETABS 2017 have been used. Using response spectrum analyses the response of the RC building considered in the present study is evaluated and compared with and without FVD. This study investigates the influence …
Published in Recent Trends in Civil Engineering & Technology · Vol. 10, Issue 2, 2020 · pp. 1–5 Read article
-
Analysis of Highrise Building Using Diaphragm in STAAD Pro at Different Zones
Abstract: Each multi-story building means a significant investment and as such multi-story building analysis is generally performed using more sophisticated techniques and procedure. Therefore, accepting modern ways to seismic analysis of multi-story buildings can be very valuable to structural engineers and researchers. Floor and roof systems act as a diaphragm to transfer the lateral load to the vertical load supporting elements like beams, columns, walls, etc. For simplicity in the dynamic …
Published in Recent Trends in Civil Engineering & Technology · Vol. 5, Issue 3, 2015 · pp. 22–34 Read article
-
Analysis of core and outrigger structural system for different soil condition
Abstract: As achievement of structural system for tall building is not easy task. As the tall building is more affected by lateral loads so design and analysis of high rise building is difficult so to minimized this effects of load now a days new different systems like outrigger system belt truss system. In this present study outrigger system is used with rigid core. In this study G+30 floor building is considered …
Published in Recent Trends in Civil Engineering & Technology · Vol. 11, Issue 3, 2021 · pp. 1–9 Read article
-
Performance of Structure with Fixed Base and Lead Rubber Bearing: Review
Abstract: Base Isolation approach is the most normally used method to defend a shape from earthquake. The thinking in the back of this approach is to detach the superstructure from floor with the aid of introducing bendy isolators between basis and superstructure. These isolators soak up electricity or vibrations and shield shape from an earthquake. Since the last fifteen years, the base isolation technique has been regarded as one of the …
Published in Recent Trends in Civil Engineering & Technology · Vol. 11, Issue 2, 2021 · pp. 30–34 Read article
-
Analysis of Retrofitting Concrete Structure Using FRP Laminates
Abstract: Retrofitting is referred to as modifying existing equipment or structure with additional or new components or members. To make older structures more resistant to accidents or seismic activity, retrofitting is referred to as modifying existing equipment or structures with new or additional members or components. An existing structure is less susceptible to damage when it is retrofitted. The use of retrofitting is on the rise right now. The structures' strength, …
Published in Recent Trends in Civil Engineering & Technology · Vol. 13, Issue 1, 2023 · pp. 17–23 Read article