Journal of Structural Engineering and Management

Dynamic Wind and Seismic Effect on Hexagrid Structure

  1. D.N. Kakde
  2. Sayed Shoeb Iliyas
  3. Huzaifa Nakhwa ✉

Abstract

As the height of the structure increases above 80m the wind lateral forces on the structure become more and more dominant than others. Furthermore, the wind dynamic calculation required for the proper Analysis of the wind. In the current paper the wind gust force has calculated by using IS 875:2015. The calculated forces have been applied on the Steel moment frame building along with the peripheral braced system. The peripheral brace system has modelled in Hexagrid pattern to exert a lateral force. The Hexagrid system is a new invention in the modern technology era which comes out by observing natural structures like a beehive and spider web structure. The wind gust force has been calculated by formulation and graphs mentioned in the IS 875:2015. The Dynamic analysis for the seismic loads has been applied as per IS 1893(Part 1):2016. Furthermore, The building has Analyzed and Designed for the applied loads and forces & the Displacement, Base shear & Storey Drift with respect to wind gust effect have been worked out.Keywords:Hexagrid, Dynamic analysis, Wind gust,Lateral force, Storey shear,Storeydrift

References (10)

  1. Ronak S Vagadiya, Deepak K Jivani, RG Dhamsaniya , MV Sanghani . A study on seismic behavior of hexagrid type structural system. International Journal of Advanced Research and Innovative Ideas. 2017; 3(2): 4412–4422.
  2. Saket Yadav, Vivek Garg. Advantage of steel diagrid building over conventional buildi ng. International Journal of Civil and Structural Engineering Research . September 2015; 3(1):394–
  3. 3. Taranath SD, Mahantesh NB , MB Patil. Comparative study of pentagrid and hexagrid structural system for tall b uilding. Journal of Civil Engineering and Environmental Technology . August 2014; 1(2): 10–15.
  4. BK Raghu Prasad, Kavya AJ , Amarnath K. Comparative performance of octagrid and hexagrid lateral load resisting systems for tall building structure. International Journal of Engineering Research and Applications. November 2014; 4(11):74–80. Dynamic Wind and Seismic Effect on Hexagrid Structure Kakde et al. © STM Journals 2021. All Rights Reserved 22
  5. Shubhangi V Pawar , MS Kakamare . Earthquake and wind analysis of diagrid structure. International Journal for Research in Applied Science & Engineering Technology. July 2017; 5(7): 1729–1739.
  6. Nishith B Panchal, Vinubhai R Patel. Diagrid structural system: strategies to reduce lateral forces on high-rise buildings. International Journal of Research in Engineering and Technology . April 2014; 3(4): 374–378.
  7. Manthan I Shah, Snehal V Mevada , Vishal B Patel. Comparative study of diagrid structures with conventional frame structures. International Journal of Engineering Research and Applications. May 2016; 6(5): 22–29.
  8. IS 800–2007Code of practice for general construction in steel.
  9. IS 875-part 1 and part 2 Code of practice for design loads (other than earthquake ) for buildings and structures.
  10. IS 1893–2016 Criteria for earthquake resistant design of structures.