Current Trends in Signal Processing
Microcontroller based Electrocardiography System with Adaptive Baseline Wander Removal
Abstract
In this paper an affordable, user-friendly, and re-programmable electrocardiography system is presented. The proposed system is based on open-source Arduino/Genuino platform which can be re-programmed and up-graded as per the requirement of the end user. This system has the facility to display, store and share the acquired data via internet with a cardiologist, for the remote assistance. The proposed system is equipped with an adaptive median filter based baseline wander removal algorithm (AMF-BWR), implemented on microcontroller.References (22)
- WHO. World Health Statis tics. World Health Organisation; 2014.
- Guyton AC, Hall J. Textbook of Medical Physiology. Philadelphia: WB Saunders Co.; 2002.
- Rangayyan RM. Biomedical Signal Analysis. IEEE Standards Office; 2001.
- Sharma H, Sharma K. Baseline Wander Removal of ECG Signals Using Hilbert Vibration Decom position. Electron Lett, IET. 2015; 51: 447–44p.
- Ravanfar M, Azinfar L, Arefin R, et al. Electrocardiogram Baseline Wander Removal B ased on Empirical Mode Decomposition. Computing in Cardiology Conference (CinC). 2014; 45–48p.
- Fasano A, Villani V. Baseline Wander Removal in ECG and AHA Recommendations. Computing in Cardiology Conference (CinC ). 2014; 1171–1174p.
- Ji T, Lu Z, Wu Q, et al. Baseline Normalisation of ECG Signals Using Empirical Mode Decomp osition and Mathematical Morpho logy Electronics Letters. The Institution of Engineering and Technology (IET). 2008; 44: 1p.
- Zhang CF, Bae TW. VLSI Friendly ECG QRS Complex D etector for Body Sensor Networks. IEEE Journal on Emerging and Selected Topics in Circuits and Systems. 2012; 2: 52–59p.
- Jiang W, Kong SG. Block-Based Neural Networks for Personalized ECG Signal Classification. IEEE Trans Neural Netw . 2007; 18: 1750–1761p.
- Shyu KK, Lee MH, Wu YT, et al. Implementation of Pipelined Fast ICA on FPGA for Real-Time Blind Source Separation. IEEE Trans Neural Netw . 2008; 19: 958–970p.
- Ramos R, Mnuel-Lzaro A, Del Rio J, et al. FPGA-Based Impleme ntation of an Adaptive Cancell er for 50/60 Hz Interference in Electrocardiography. IEEE Trans Instrum Meas. New York: Institute of Electrical and Electronics Engineers . 2007; 56: 2633–2640p.
- Bhaskar P, Kasture A. Minimization of Base-Line Drift Interference from ECG Signal Using FPGA Based Adaptive Filter. International Conference on Computing Communication Control and Automation (ICCUBEA). 2015; 937–941p. Electrocardiography System with Adaptive BWR Sharma and Sun karia CTSP (2017) 29-34 © STM Journals 2017. All Rights Reserved Page 34
- Ravanfar M, Azinfar L, Are _n R, et al. Electrocardiogram Baseline Wander Removal Bas ed on Empirical Mode Decomposition. Computing in Cardiology Conference (CinC). 2014; 45–48p.
- Pan N, Mang V, Un MP, et al. Accurate Removal of Baseline Wa nder in ECG Using Empirical Mode Decomp osition. Joint Meeting of the 6th International Symposium on Noninvasive Functional Source Imaging of the Brain and Heart and the International Conference on Functional Biomedical Imaging, NFSI - ICFBI. 2007; 177–180p.
- Arduino/Genuino (2016) https://www.arduino.cc/
- Dohare AK, Kumar V, Kumar R. An Efficient New Method for the Detection of QRS in Electrocardiogram. Computers and Electrical Engineering (CEE), Elsevier. 2014; 40: 1717–1730p.
- Sharma LD, Sunkaria RK. A Robust QRS Detection Using Novel Pre -Processing Techniques and Kurtosis Based Enhanced Efficiency. Measurement. 2016; 30(87): 194–204p.
- Awodeyi AE, Alty SR, Ghavami M. Median Filter Approach for Removal of Baseline Wander in Photoplethysmography Signals . European Modelling Symposium (EMS ). 2013; 261– 264p.
- Shrestha S. Image Denoising Using New Adaptive based median lter. Signal and Image Processing: An International Journal (SIPIJ), Academy and Industry Research Collaboration Center (AIRCC ). 2014; 5: 1p.
- Goldberger AL, Amaral LAN, Glass L, et al. PhysioBank, PhysioToolkit and PhysioNet, Components of a New Research Resource for Complex Physiologic Signals . Circulation. 2000; 101(23): e215–e220p.
- Moody GB, Mark RG. The Impact of the MIT-BIH Arrhythmia Database. Eng Med Biol Mag, IEEE. 2001; 20: 45–50p.
- Baim DS, Colucci WS, Monrad ES, et al. Survival of Patients with Severe Congestive Heart Failure Tre ated with Oral Milrinone. J Am Coll Cardiol . 1986; 7(3): 661–70p. Cite this Article Lakhan Dev Sharma, Ramesh Kumar Sunkaria. Microcontroller based Electrocardiography System with Adaptive Baseline Wander Removal. Current Trends in Signal Processing. 2017; 7(1): 29–34p.