1 publication
-
Published Subscription
Analytical Study on Optimum Placement and Sizing of X-Plate Metallic Dampers for Seismic Response Control of Multistoried RC Building FrameBy Tatya D. Vavhule, R.S. Londhe
Abstract: X-plate metallic damper (XPD) is one device that is capable of sustaining many cycles of stable yielding deformation resulting in a high level of energy dissipation or damping. For quantification of effectiveness of XPD, optimum placement and sizing of XPD are one of the practical interest. This paper investigates effect of placement and sizing of X-Plate damper on a G+3 square shaped building. The most optimal damper placement location pattern …
Published in Journal of Structural Engineering and Management · Vol. 4, Issue 2, 2017 · pp. 6–12 Read article →