1 publication
-
Published Subscription
Comparative Analysis of Vapour Compression Mini Ice Cream Plant by Using Different Size Capillary TubesBy Rajkumar Singh Chauhan, Neelesh Soni, Siddhartha Kosti
Abstract: Abstract An experimental set up is made for comparative analysis of vapour compression mini ice cream plant by applying different size capillary tubes. The experiments were performed and results were recorded for comparing the best unit. The capillary tube was formed in coil shape having different inner diameters such as 0.79 and 1.12 mm. The pressure at suction and discharge of capillary were recorded to evaluate the cycle COP, power …
Published in Journal of Refrigeration, Air conditioning, Heating and ventilation · Vol. 3, Issue 3, 2016 · pp. 30–34 Read article →